This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
80
1
2
wound01_e-02
■
PART NUMBERS
●1608
0603)
(
TYPE
Ordering code
LB 1608T1R0M
LB 1608T2R2M
LB 1608T4R7M
LB 1608T8R2M
LB 1608T100M
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
〔μH〕
1.0
2.2
4.7
8.2
10
Inductance
〔μH〕
1.0
2.2
3.3
4.7
10
22
47
Inductance
Tolerance
Self-resonant frequency
〔MHz〕
min.
100
80
45
32
32
Self-resonant frequency
〔MHz〕
min.
100
80
60
45
32
16
11
DC Resistance
〔Ω〕±30%)
(
0.17
0.33
0.55
0.70
0.70
DC Resistance
〔Ω〕±30%)
(
0.09
0.17
0.22
0.24
0.36
1.0
2.5
Rated current
max.
〔mA〕
160
115
70
60
60
Rated current
max.
〔mA〕
230
160
130
110
80
50
35
Measuring frequency
〔MHz〕
7.96
±20%
2.52
Ordering code
LBMF1608T1R0M
LBMF1608T2R2M
LBMF1608T3R3M
LBMF1608T4R7M
LBMF1608T100□
LBMF1608T220□
LBMF1608T470□
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
Tolerance
±20%
Measuring frequency
〔MHz〕
7.96
±10%
±20%
2.52
INDUCTORS STANDARD INDUCTORS
・□Please
specify the Inductance tolerance code K or M)
(
●2012
0805)
(
TYPE
Ordering code
LB 2012T1R0M
LB 2012T2R2M
LB 2012T3R3M
LB 2012T4R7M
LB 2012T6R8M
LB 2012T100□
LB 2012T100□R
LB 2012T150□
LB 2012T220□
LB 2012T470□
LB 2012T680□
LB 2012T101□
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
〔μH〕
1.0
2.2
3.3
4.7
6.8
10
10
15
22
47
68
100
Inductance
Tolerance
Self-resonant frequency
〔MHz〕
min.
100
80
55
45
38
32
32
28
16
11
10
8
DC Resistance
〔Ω〕±30%)
(
0.15
0.23
0.30
0.40
0.47
0.70
0.50
1.3
1.7
3.7
6.0
7.0
Rated current
max.
〔mA〕
405
260
235
190
135
120
120
100
80
60
50
45
Measuring frequency
〔MHz〕
/
±20%
7.96
±10%
±20%
2.52
0.796
・□Please
specify the Inductance tolerance code K or M)
(
Ordering code
LB C2012T1R0M
LB C2012T2R2M
LB C2012T4R7M
LB C2012T100□
LB C2012T220□
LB C2012T470□
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
〔μH〕
1.0
2.2
4.7
10
22
47
Inductance
Tolerance
±20%
±10%
±20%
Self-resonant frequency
〔MHz〕
min.
100
70
45
40
16
11
DC Resistance
〔Ω〕±30%)
(
0.19
0.33
0.50
1.2
3.7
5.8
Rated current
max.
〔mA〕
620
430
295
200
130
90
Measuring frequency
〔MHz〕
7.96
2.52
・□Please
specify the Inductance tolerance code K or M)
(
Ordering code
LB R2012T1R0M
LB R2012T2R2M
LB R2012T4R7M
LB R2012T100□
LB R2012T220□
LB R2012T470□
LB R2012T101□
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
〔μH〕
1.0
2.2
4.7
10
22
47
100
Inductance
Tolerance
±20%
±10%
±20%
Self-resonant frequency
〔MHz〕
min.
100
80
45
32
16
11
8
DC Resistance
〔Ω〕±30%)
(
0.07
0.13
0.24
0.36
1.0
1.7
4.0
Rated current
max.
〔mA〕
400
260
200
150
100
75
50
Measuring frequency
〔MHz〕
7.96
2.52
0.796
・□Please
specify the Inductance tolerance code K or M)
(
●2016
0806)
(
TYPE
Ordering code
LB 2016T1R0M
LB 2016T1R5M
LB 2016T2R2M
LB 2016T3R3M
LB 2016T4R7M
LB 2016T6R8M
LB 2016T100□
LB 2016T150□
LB 2016T220□
LB 2016T330□
LB 2016T470□
LB 2016T680□
LB 2016T101□
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
〔μH〕
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
Inductance
Tolerance
Self-resonant frequency
〔MHz〕
min.
100
80
70
55
45
38
32
28
16
14
11
10
8
DC Resistance
〔Ω〕±30%)
(
0.09
0.11
0.13
0.20
0.25
0.35
0.50
0.70
1.0
1.7
2.4
3.0
4.5
Rated current
max.
〔mA〕
490
380
375
285
225
200
155
130
105
85
70
55
40
Measuring frequency
〔MHz〕
±20%
7.96
±10%
±20%
2.52
0.796
・□Please
specify the Inductance tolerance code K or M)
(
*
This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
wound01_e-02
1
2
81
■
PART NUMBERS
Ordering code
LB C2016T1R0M
LB C2016T1R5M
LB C2016T2R2M
LB C2016T3R3M
LB C2016T4R7M
LB C2016T6R8M
LB C2016T100□
LB C2016T150□
LB C2016T220□
LB C2016T330□
LB C2016T470□
LB C2016T680□
LB C2016T101□
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
〔μH〕
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
Inductance
Tolerance
Self-resonant frequency
〔MHz〕
min.
100
80
70
55
45
38
32
28
16
14
11
10
8
DC Resistance
〔Ω〕±30%)
(
0.10
0.15
0.20
0.27
0.37
0.59
0.82
1.2
1.8
2.8
4.3
7.0
8.0
Rated current
max.
〔mA〕
690
600
520
410
355
290
245
200
165
135
110
95
75
Measuring frequency
〔MHz〕
±20%
7.96
±10%
±20%
2.52
0.796
・□Please
specify the Inductance tolerance code K or M)
(
●2518
1007)
(
TYPE
Ordering code
LB 2518T1R0M
LB 2518T1R5M
LB 2518T2R2M
LB 2518T3R3M
LB 2518T4R7M
LB 2518T4R7MR
LB 2518T6R8M
LB 2518T100□
LB 2518T150□
LB 2518T220□
LB 2518T330□
LB 2518T470□
LB 2518T680□
LB 2518T101□
LB 2518T151□
LB 2518T221□
LB 2518T331□
LB 2518T471□
LB 2518T681□
LB 2518T102□
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
〔μH〕
1.0
1.5
2.2
3.3
4.7
4.7
6.8
10
15
22
33
47
68
100
150
220
330
470
680
1000
Inductance
Tolerance
Self-resonant frequency
〔MHz〕
min.
100
80
68
54
46
46
38
30
23
19
15
12
9.5
9.0
7.0
5.5
4.5
3.5
3.0
2.4
DC Resistance
〔Ω〕±30%)
(
0.06
0.07
0.09
0.11
0.13
0.10
0.15
0.25
0.32
0.50
0.70
0.95
1.5
2.1
3.2
4.5
7.0
10
17
24
Rated current
max.
〔mA〕
665
405
340
280
240
235
195
165
145
115
95
85
70
60
45
40
30
25
20
15
Measuring frequency
〔MHz〕
±20%
7.96
2.52
±10%
±20%
0.796
0.252
・□Please
specify the Inductance tolerance code K or M)
(
Ordering code
LB C2518T1R0M
LB C2518T1R0MR
LB C2518T1R5M
LB C2518T2R2M
LB C2518T3R3M
LB C2518T4R7M
LB C2518T6R8M
LB C2518T100□
LB C2518T150□
LB C2518T220□
LB C2518T330□
LB C2518T470□
LB C2518T680□
LB C2518T101□
LB C2518T151□
LB C2518T221□
LB C2518T331□
LB C2518T471□
LB C2518T681□
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
〔μH〕
1.0
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
150
220
330
470
680
Inductance
Tolerance
±20%
±10%
±20%
Self-resonant frequency
〔MHz〕
min.
100
100
80
68
54
41
38
30
23
19
15
12
9.5
9.0
7.0
5.5
4.5
3.5
3.0
DC Resistance
〔Ω〕±30%)
(
0.080
0.065
0.11
0.13
0.16
0.20
0.30
0.36
0.65
0.77
1.5
1.9
2.8
3.7
6.1
8.4
12.3
22
28
Rated current
max.
〔mA〕
775
890
730
630
560
510
420
375
285
250
185
165
140
125
95
80
65
50
45
Measuring frequency
〔MHz〕
7.96
2.52
0.796
・□Please
specify the Inductance tolerance code K or M)
(
Ordering code
LB R2518T1R0M
LB R2518T2R2M
LB R2518T4R7M
LB R2518T100□
LB R2518T220□
LB R2518T470□
LB R2518T101□
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
〔μH〕
1.0
2.2
4.7
10
22
47
100
Inductance
Tolerance
±20%
±10%
±20%
Self-resonant frequency
〔MHz〕
min.
100
68
45
30
19
11
9
DC Resistance
〔Ω〕±30%)
(
0.045
0.07
0.10
0.19
0.44
0.84
1.89
Rated current
max.
〔mA〕
960
480
345
235
175
120
80
Measuring frequency
〔MHz〕
7.96
2.52
0.796
・□Please
specify the Inductance tolerance code K or M)
(
*
This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
82
1
2
wound01_e-02
■
PART NUMBERS
●3218
1297)
(
TYPE
Ordering code
LB 3218T1R0M
LB 3218T1R5M
LB 3218T2R2M
LB 3218T3R3M
LB 3218T4R7M
LB 3218T6R8M
LB 3218T100□
LB 3218T150□
LB 3218T220□
LB 3218T330□
LB 3218T470□
LB 3218T680□
LB 3218T101□
LB 3218T151□
LB 3218T221□
LB 3218T331□
LB 3218T471□
LB 3218T681□
LB 3218T102□
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
〔μH〕
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
150
220
330
470
680
1000
Inductance
Tolerance
Self-resonant frequency
〔MHz〕
min.
100
80
68
54
41
40
30
25
19
15
12
11
8
7
5
4
3.5
3.0
2.4
DC Resistance
〔Ω〕±30%)
(
0.06
0.07
0.09
0.11
0.13
0.17
0.25
0.32
0.49
0.75
0.92
1.49
2.4
3.2
5.4
7.0
14
17
27
Rated current
max.
〔mA〕
1075
860
775
560
550
380
340
300
255
215
205
145
140
105
80
65
54
45
39
Measuring frequency
〔MHz〕
±20%
7.96
2.52
±10%
±20%
INDUCTORS STANDARD INDUCTORS
0.796
0.252
・□Please
specify the Inductance tolerance code K or M)
(
/
●3225
1210)
(
TYPE
Ordering code
LB C3225T1R0MR
LB C3225T1R5MR
LB C3225T2R2MR
LB C3225T3R3MR
LB C3225T4R7MR
LB C3225T6R8MR
LB C3225T100□R
LB C3225T150□R
LB C3225T220□R
LB C3225T330□R
LB C3225T470□R
LB C3225T680□R
LB C3225T101□R
EHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
Inductance
〔μH〕
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
Inductance
Tolerance
Self-resonant frequency
〔MHz〕
min.
250
220
190
160
70
50
23
20
17
13
10
8
6
DC Resistance
〔Ω〕±30%)
(
0.055
0.060
0.080
0.095
0.100
0.120
0.133
0.195
0.27
0.41
0.67
1.0
1.4
Rated current
max.
〔mA〕
1100
1000
930
820
680
620
540
420
330
300
220
190
150
Measuring frequency
〔MHz〕
±20%
0.1
±10%
±20%
・□Please
specify the Inductance tolerance code K or M)
(
*
This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
Everyone must be familiar with GPS. Everyone should know that decoding GPS is not difficult and the principle is very simple. Anyway, let's introduce the process and related knowledge in detail. GPS i...
MP3 chargers are one of the most easily damaged accessories. After repairing many types of chargers, I found that they basically all use switching power supply circuits, and the circuit structures are...
When I use this function to write the south bridge address, it will cause the system to restart, using ICOP's DX processor: void WriteSouthBridge(unsigned char idx, DWORD val) { __asm { push edx mov d...
[font=微软雅黑]From now until October 24th[/font] [font=微软雅黑]Buy [b]2[/b] units of F-101/F-101Kit and get a free stylish ultra-thin wireless mouse[/font] [font=微软雅黑]Buy [b]1[/b] unit of F-106 and get a fr...
introduction
With the continuous optimization of surface mount technology (SMT) and the rapid development of chip component manufacturing technology, the application of chip mounters in the el...[Details]
1. Introduction
Automobile pollution is one of the most important issues that people are most concerned about and need to solve urgently. As an important method for detecting automobile exhau...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
Due to the significant increase in electronic devices in automotive and industrial applications, the automotive and industrial markets continue to play an important role in China's electronics in...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
introduction
MEMS is a high-tech that has flourished on the basis of integrated circuit production technology and dedicated micro-electromechanical processing methods. Pressure sensors develop...[Details]
Motors are important products that convert electrical energy into mechanical energy to achieve automation, and they are widely used in industrial control, medical electronics, white a...[Details]
According to the Industrial Technology Research Institute of Taiwan, due to factors such as the oil crisis and global warming, the issues of energy conservation and environmental protection have at...[Details]
Abstract: With the development and construction of BeiDou II system, China will shift from the situation dominated by GPS to the situation dominated by BeiDou II global navigation system independen...[Details]