BK-MDA-1-100

Description
cartridge fuses small dim fuse SB
CategoryCircuit protection   
File Size272KB,2 Pages
ManufacturerBussmann (Eaton)
Download Datasheet Parametric View All

BK-MDA-1-100 Online Shopping

Suppliers Part Number Price MOQ In stock  
BK-MDA-1-100 - - View Buy Now

BK-MDA-1-100 Overview

cartridge fuses small dim fuse SB

BK-MDA-1-100 Parametric

Parameter NameAttribute value
ManufactureCooper Bussm
Product CategoryCartridge Fuses
RoHSN
Body StyleCylindrical
Current Rating10 mA
Voltage Rating AC250 V
Mounting StyleHolder / Cli
Fuse TypeTime Delay / Slow Blow
Fuse Size / Grou3AB (6.3 mm x 32 mm)
Dimensions31.75 mm L x 6.35 mm D
Case Diamete6.35 mm
Case Length31.75 mm
Indicator StyleWithout Indic
PackagingBulk
ProducSpecialty Fuses
Termination StyleCli
TypeElectronic Time Delay Ferrule Fuse
Unit Weigh453.592 mg
/
4
˝ x 1
1
/
4
˝ Ceramic Tube Fuses
MDA Series,
Time-Delay
1
Description
• Time-delay
• Optional axial leads available
• 1/4˝ x 1-1/4˝ (6.35 x 31.75mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
Electrical Characteristics
Rated Current
Amp Rating
Opening Time
100%
None
1/4 - 30A
135%
60 Minutes Max.
200%
120 Seconds Max.
Dimensions - mm (in)
Drawing Not to Scale
38.10
(1.500)
32.82
(1.292)
38.10
(1.500)
Agency Information
• UL Listed Card: MDA 2/10 - 20A (Guide JDYX,
File E19180)
• UL Recognized Card: MDA 25 - 30A (Guide JDYX2,
File E19180)
• CSA Certification Card: MDA 2/10 - 20
(Class No. 1422-01)
• CSA Component Acceptance: MDA 25-30A
(Class No. 1422-30)
Environmental Data
• Shock: 1/100A and 8/10A – MIL-STD-202,
Method 213, Test Condition I;
1A thru 30A – MIL-STD-202, Method 213,
Test Condition J
• Vibration: 1/100A and 8/10A – MIL-STD-202,
Method 201; 1/4A thru 30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
6.76
(0.266)
DIA. OF LEADS
0.81
0–15 AMP:
(0.032)
20–30 AMP: 1.02
(0.040)
31.75
(1.250)
6.35
(0.250)
Ordering
• Specify packaging, product, and option code
SPECIFICATIONS
Part
Number
MDA-1/4-R
MDA-1/2-R
MDA-3/4-R
MDA-1-R
MDA-1-1/2-R
MDA-2-R
MDA-2-1/2-R
MDA-3-R
MDA-4-R
MDA-5-R
MDA-6-R
MDA-7-R
MDA-8-R
MDA-10-R
MDA-12-R
MDA-15-R
MDA-20-R
MDA-25A-R
MDA-30A-R
*
**
Voltage
Rating
Vac
Vdc
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
-
250
125
250
125
250
125
AC Interrupting
Rating* (amps)
250V
125V
35
10000
35
10000
35
10000
35
10000
100
10000
100
10000
200
10000
200
10000
200
10000
200
10000
200
10000
200
10000
200
10000
200
10000
750
10000
750
10000
1500
10000
1500
10000
1500
10000
DC Interrupting
Rating (amps)
125V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
10000
10000
10000
Typical DC Cold
Resistance**
Ω
(Ω)
9.325
1.925
0.8555
0.560
0.2585
0.170
0.06685
0.05350
0.03625
0.02610
0.02120
0.01690
0.01350
0.00948
0.00725
0.00553
0.00400
0.00305
0.00243
Typical
Melting I
2
t†
AC
0.748
2.53
8.58
12.21
27.5
70.4
31.79
44.99
147.4
380.49
587.73
638.33
1038.4
1620.43
125.18
336.82
483.45
734.69
1096.7
Typical
Voltage
Drop‡
4.00
1.42
1.31
1.03
0.691
0.623
0.213
0.182
0.162
0.145
0.141
0.137
0.134
0.135
0.128
0.107
0.095
0.105
0.110
Interrupting Ratings (Measured at 70% - 80% power factor on AC. The interrupting ratings for 25Amp, 30Amp were measured at 90% - 100% power factor on AC)
DC Cold Resistance (Measured at ≤10% of rated current)
Typical Melting I
2
t (A
2
Sec) (I
2
t was measured at listed interrupting rating and rated voltage)
Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current)
0709
SB-BU09312
Page 1 of 2
Data Sheet 2002
How to clear the "missed call" notification bubble in the system tray bar at the top of the screen?
{ 0xA877D660, 0x239C, 0x47A7, { 0x93,...
lcw433 Embedded System
Reducing RFI Rectification Error in Instrumentation Amplifier Circuits
[size=2][b]The article is well written, so I reprinted it here. [/b][/size] [size=4] [/size] [size=4] In practical applications, we must deal with increasing amounts of radio frequency interference (R...
dontium ADI Reference Circuit
How big a number can be written in hexadecimal 00f0 to 00f4
How big a number can be written in hexadecimal 00f0 to 00f4...
dinghao1 MCU
4 books you must read to learn FPGA
I believe that many comrades are learning FPGA, but they don’t know which books to read in the process of learning FPGA? 1. First, you should learn C language (Tan Haoqiang’s book is the classic) 2. S...
zhouweifeng919 FPGA/CPLD
MCU Instructions (III)
2. Data transfer instructions between accumulator A and off-chip RAMMOVX A,@Ri MOVX@Ri,A MOVX A,@DPTR MOVX @DPTR,A illustrate: 1) In 51, the only accumulator that can interact with the external RAM is...
rain MCU
[Shanghai Hangxin ACM32F070 development board + touch function evaluation board evaluation] + use of GPIO port
[i=s]This post was last edited by jinglixixi on 2022-10-3 01:31[/i]Learning about the GPIO port is the best way to master the use of the development board, and analyzing and learning from routines is ...
jinglixixi Domestic Chip Exchange

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2412  1967  2762  2714  1465  49  40  56  55  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号