Power Entry Modules with Line Filter
www.schurter.com /PG06
EF12
Standard- or Medical-Filter
IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)
C20
70° C
Description
- Panel Mount :
Screw-on mounting from front side
- 3 Functions :
Appliance Inlet Protection class I , circuit breaker type TA45 2-pole
, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
Characteristics
-
-
-
-
All single elements are already wired
Circuit Breaker non-illuminated or illuminated
With EMC-shield
Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
References
Weblinks
Approvals
- Variant with notch for V-Lock mating Cordsets
Alternative: version without line filter
EF11
Alternative: Standard version
pdf datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
- Approval Reference Type: EF12
- VDE Certificate Number: 40001520
- UL File Number: E72928
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
12 - 16 A @ Ta 40 °C / 250 VAC; 50 Hz
12 - 20 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
C20 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection Class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In
≥
3A/240VAC : 300A
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 100'000 h acc. to MIL-HB-217 F
Circuit Breakers
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
Protection Class
Terminal
Panel Thickness S
Material: Housing
Line Filter
MTBF
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
General Product
Information
EMC Products
1
Power Entry Modules with Line Filter
www.schurter.com /PG06
EF12
Technical data (continued)
Circuit breaker
Tripping characteristics
I
n
< 3 A
[ min ] [ sec ]
10'000
Tripping characteristics
I
n
> 3… < 18 A
[ min ] [ sec ]
10'000
Tripping characteristics
I
n
> 18 A
[ min ] [ sec ]
10'000
Type
Rated current
TA45
In <3 A
1 pole protected
Type
Rated current
TA4 5
In > 3 A... < 18 A
1 pole protected
2 pole protected
Type
Rated current
TA4 5
In >18 A
1 pole protected
60
30
20
10
5
200
100
1
50
20
10
5
2
1
0,5
Tripping time
2`000
1`000
500
60
30
20
10
5
200
100
1
50
20
10
5
2
1
0,5
2`000
1`000
500
60
30
20
10
5
200
100
1
50
20
10
5
2
1
0,5
Tripping time
0,3
0,2
0,1
1,05 1,32
2
2`000
2 pole protected
2 pole protected
1`000
500
Ambient temp.
+23 °C
Ambient temp.
+23 °C
Ambient temp.
+23 °C
Tripping time
0,3
0,2
0,1
1,05 1,32
2
3
4
5
8
10
[ x In ]
0,3
0,2
0,1
1,05 1,32
2
3
4
5
8
10
[ x In ]
3
4
5
8
10
Multiple of rated current
Multiple of rated current
Multiple of rated current
[ x In ]
1) Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23 °C. To de-
termine the rated current for a lower or higher ambient temperature,
use a correction factor from the table on the right side:
* Ambient temperature [°C]
–10
–5
0
+23
+30
+40
+55
Correction factor
0,89
0,91
0,92
1,00
1,03
1,08
1,16
* Temperature must be measured at the rear of the breaker next
to the terminals after equipment operating temperature has been
reached.
1) Example
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at
+40 °C ambient temperature
6,0 A
+40 °C
1,08
6 A x 1,08 = 6,5 A
Configuration code (example)
Type
Order code TA45
(2-pole rocker-switch
without accessories)
Color
0
black
Interlocking
0
without V-Lock
1
with V-Lock
Terminal PE
1
QC 6.3x0.8
Terminal L and N
1
QC 6.3x0.8, without connection to TA45
3
Connection to TA45 non insulated
Type of mains filter / capacitor / bleed resistor
1
standard
X2,Y2
with bleed resistor
2
medical M5
X2
with bleed resistor
Rated current
1
20 A
2
16 A
3
12 A
1)
EF12 - ABTWF150C0 - 000 - 1111 - 00 - 00
see table 1
1) The rated current of the line-filter must be equal
or more than the rated current of TA45.
EMC Products
5