EEWORLDEEWORLDEEWORLD

Part Number

Search

RC310G-1M2307PB

Description
Rotary Switch
CategoryMechanical and electronic products    switch   
File Size147KB,7 Pages
ManufacturerFuji Electric Co., Ltd.
Download Datasheet Parametric View All

RC310G-1M2307PB Overview

Rotary Switch

RC310G-1M2307PB Parametric

Parameter NameAttribute value
Objectid1588104971
Reach Compliance Codeunknown
ECCN codeEAR99
Manufacturer's serial numberRC310
Switch typeROTARY SWITCH
Cam Type
RC310
Control selector switches
Cam-type control selector
switches
Description
FUJI cam-type control switches are
recommended for use on switchboards,
control panels and switchgear because
of their reliability in service. The main
type is RC310 with operational current
ratings of 10A.
Simplified and economical circuits can be
designed around the RC310, since it can
handle loads of up to 10A at 220VAC
without the need of contactors. Typical
examples of complex circuits based on
the attractive features of these
economical cam-type selector switches
are given on pages 04/265 to 04/268.
FUJI is prepared to manufacture other
versions to suit your particular
applications, and switches with up to 12
selector positions can be made to order.
RC310 switches are normally supplied
with H-type handles. Alternative handle
shapes available include the pistol-grip
P-type, cane-handle shaped S-type and
rosette shaped R-type.
Switches with a 2-12 position maintained
type, 3-position center spring-return type
and center spring-return type with locking
device are also available.
Type
Flush mounting
x-type
Semi-flush mounting
Enclosed
g-type
RC310-1
SG-740
SG-743
AF-191
RC310x-1
RC310-1
RC310g-1
Ratings
Rated thermal
current
(A)
10
Breaking capacity (A)
Voltage
AC
(V)
Inductive
24
110
220
440
550
10
7.5
7.5
2.5
2
DC
Resistive
10
3
0.8
0.4
0.3
DC
Inductive
5
1.3
0.45
0.2
0.15
Type
RC310-1
04
Technical data
Insulation resistance: Over 100MΩ at 500VDC
Dielectric strength: 2,500VAC. 1 minute
Ambient temperature: –5° to +60°C
Operating cycle: 600 cycles/hour
Life expectancy (operations)
Mechanical
Electrical
250,000 at 220VAC 7.5A
500,000 at 220VAC 3A
Type
RC310-1 5 million
Contact arrangement:
See page 04/265
.
Contact arrangement (typical)
(Viewed from the direction of the handle)
Ordering information
Specify the following
(See page 04/264):
1.
2.
3.
4.
5.
6.
7.
8.
Type number
Mounting method
Operation
Selector position and notch angles
No. of contact blocks
Contact arrangement
Handle
Handle colors
Handle
Contact
of upper Nos. of selector
positions
side
Contact of
lower side
Example
Cam switch,
rated current 10A .................. RC310-1
Flush mounting ............................ x
Maintained operation ......................... M
Contact arrangement ............................. 3201
(3-position, 2 contact blocks,
H type handle ................................................... H
Black color handle............................................... B
Type number
RC310x-1M3201HB
Note: “C” in the type No. nomenclature must be
filled with numbers appearing in the table of “The
Contact Arrangement”.
(page 04/265)
When requiring special arrangements not appearing
in the list clearly specify the arrangement required.
Note that “C” in the type nomenclature must not be
removed in this case.
RC310x-1MCHB
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
04/263
EEWORLD University Hall - Sharing of household heating and cooling inverter air conditioner application solutions based on Lingdong MM32SPIN series MCU
Sharing of household heating and cooling inverter air conditioner application solutions based on MM32SPIN series MCU : https://training.eeworld.com.cn/course/5661Introduction to variable frequency air...
EE大学堂 MCU
New generation of wireless remote street light control system
[b] The existing urban lighting control system generally adopts the method of setting up multiple switch cabinets to control the entire city lighting in sections. Each switch cabinet is generally resp...
fybao2000 Embedded System
Interrupt nesting problem
[size=14px]I am now using UART interrupt and RTC interrupt[/size] [size=14px]After receiving data, the system will send data after the RTC interrupt enters 6 times. If the transmission permission (thi...
che00ng Microcontroller MCU
What is the impact of national policies on small and medium-sized enterprises?
As an employee, being able to enjoy a series of national protection policies naturally gives me a sense of belonging. However, I didn’t pay attention to the impact on my boss, let alone the “impact” o...
babbage Automotive Electronics
Do you know what LE is? Check it out
A logic cell consists of a lookup table, a flip-flop, and circuitry to connect to nearby cells. The lookup table uses combinatorial logic to implement a 4-input logic expression (AND, OR, NAND, additi...
lixinsir FPGA/CPLD
Calculation of TDA2030 magnification
The amplification factor of TDA2030 is approximately equal to R10/R11 according to this figure. Why is there such a big difference in the simulation result?...
零下12度半 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 124  965  498  1771  63  3  20  11  36  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号