EEWORLDEEWORLDEEWORLD

Part Number

Search

T492A474K025RS42527610

Description
Tantalum Capacitor, Polarized, Tantalum, 25V, 10% +Tol, 10% -Tol, 0.5uF, 1206,
CategoryPassive components    capacitor   
File Size678KB,5 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

T492A474K025RS42527610 Overview

Tantalum Capacitor, Polarized, Tantalum, 25V, 10% +Tol, 10% -Tol, 0.5uF, 1206,

T492A474K025RS42527610 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Objectid708749648
package instruction, 1206
Reach Compliance Codenot_compliant
ECCN codeEAR99
capacitance0.5 µF
Capacitor typeTANTALUM CAPACITOR
dielectric materialsTANTALUM (DRY/SOLID)
ESR14000 mΩ
high1.6 mm
JESD-609 codee0
length3.2 mm
negative tolerance10%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingBulk
polarityPOLARIZED
positive tolerance10%
Rated (DC) voltage (URdc)25 V
seriesT492
size code1206
Terminal surfaceTin/Lead (Sn90Pb10)
width1.6 mm
SOLID TANTALUM CHIP CAPACITORS
T492 SERIES – Style CWR11 Per Mil-PRF-55365/8
Established reliability military version of
Industrial Grade T491 series
Taped and reeled per EIA 481-1
Precision-molded, laser-marked case
Symmetrical, compliant terminations
100% Surge Current test available for all case sizes
Operating Temperature: -55˚C to + 125˚C
CATHODE (-) END
VIEW
W
SIDE VIEW
B
B
H
K
X
S
T
G
S
Qualified to MIL-PRF-55365/8, Style CWR11:
– Termination
Options B, C, H, K
– Weibull failure rate codes B, C and D
– Capacitance values and voltages as shown
in following part number table. (Contact
KEMET for latest qualification status)
T492 OUTLINE DRAWINGS
ANODE (+) END
VIEW
BOTTOM VIEW
E
P
P
R
Termination
cutout at
KEMET’s
Option,
either end
F
A
L
Case Size
KEMET
A
B
C
D
EIA
3216-18
3528-21
6032-28
7343-31
L*
3.2 ± 0.2
(.126 ± .008)
3.5 ± 0.2
(.138 ± .008)
6.0 ± 0.3
.236 ± .012
7.3 ± 0.3
(.287 ± .012)
DIMENSIONS –
Millimeters (Inches)
Component
B
± 0.15
(Ref) ± .006
0.4
(.016)
0.4
(.016)
0.5
(.020)
0.5
(.020)
W*
1.6 ± 0.2
(.063 ± .008)
2.8 ± 0.2
(.110 ± .008)
3.2 ± 0.3
(.126 ± .012)
4.3 ± 0.3
(.169 ± .012)
H*
1.6 ± 0.2
(.063 ± .008)
1.9 ± 0.2
(.075 ± .008)
2.5 ± 0.3
(.098 ± .012)
2.8 ± 0.3
(.110 ± .012)
F*
± 0.1
± (.004)
S*
± 0.3
± (.012)
X
(Ref)
P
(Ref)
R
(Ref)
T
(Ref)
0.13
(.005)
0.13
(.005)
0.13
(.005)
0.13
(.005)
A
(Min)
G
(Ref)
E
(Ref)
1.2
(.047)
2.2
(.087)
2.2
(.087)
2.4
(.094)
0.8
(.031)
0.8
(.031)
1.3
(.051)
1.3
(.051)
0.10 ± 0.10
0.4
0.4
(.004 ± .004) (.016) (.016)
0.10 ± 0.10
0.5
1.0
(.004 ± .004) (.020) (.039)
0.10 ± 0.10
0.9
1.0
(.004 ± .004) (.035) (.039)
0.10 ± 0.10
0.9
1.0
(.004 ± .004) (.035) (.039)
1.4
1.1
1.3
(.055) (.043) (.051)
1.1
1.8
2.2
(.043) (.071) (.087)
3.1
2.8
2.4
(.122) (.110) (.094)
3.8
3.5
3.5
(.150) (.138) (.138)
Notes: 1. Metric dimensions govern
2. (Ref) Dimensions provided for reference only
* Mil-PRF-55365/8 Specified Dimensions
ORDERING INFORMATION —
MIL-PRF-55365 Part Number
CWR11
Style
Capacitors, Chip, Fixed Tantalum
Established Reliability, (encapsulated)
M
H
105
K
B
A
Surge Current Option
A = +25°C after Weibull
B = -55°C +85°C after Weibull
C = -55°, & +85°C before Weibull
Z = None
Voltage
C = 4V
D = 6V
F = 10V
H = 15V
J = 20V
K = 25V
M - 35V
N = 50V
Failure Rate Symbol
B (0.1%/1000 hrs.)
C (0.01%/1000 hrs.)
D (0.001%/1000 hrs.)
#Exponential: M (1.0%/1000 hrs.)
# Inactive for
P (0.1%/1000 hrs.)
New Design
R (0.01%/1000 hrs.)
S (0.001%/1000 hrs.)
Weibull:
Termination Finish Code
B = Gold Plated
H = Solder Plated
C = Hot Solder Dipped
K = Solder Fused
Capacitance Picofarad Code
First two digits represent significant figures.
Third digit specifies number of zeros to follow.
Capacitance Tolerances
M = ±10%; K = ±10%; J = ±5%
T492 SERIES ORDERING INFORMATION —
KEMET Part Number
T
Tantalum
Series
T492 - Precision Molded, Style CWR11
492
B
105
K
035
B
S
4250
Surge Current Option
4250 = +25°C after Weibull
4251 = -55° +85°C after Weibull
4252 = -55, & +85°C before Weibull
Case Size
A, B, C, D
Lead Material
B = Gold
C = Hot Solder Dip
H or S = Solder Plated
K = Solder Fused
Capacitance Picofarad Code
First two digits represent significant figures.
Third digit specifies number of zeros to follow.
Capacitance Tolerances
M = ±20%; K = ±10%; J = ±5%
Failure Rate Symbol
Weibull: B (0.1%/1000 hrs.); C (0.01%/1000 hrs.); D (0.001%/1000 hrs.)
# Exponential: M (1.0%/1000 hrs.); P (0.1%/1000 hrs.), R (0.01%/1000 hrs.);
S (0.001%/1000 hrs.)
# Exponential not recommended for new design
Voltage
As shown
* Part Number Example: T492B105K035BS (14 digits - no spaces)
* See www.kemet.com for Pb Free transition.
#
Note on Failure Rates: Exponential failure rate levels M, P, R and S are inactive for new design per Mil-C-55365.
Parts qualified to Weibull failure rate levels are substitutable for exponential failure rate levels.
20
©KEMET Electronics Corporation, P.O. Box 5928, Greenville, S.C. 29606, (864) 963-6300
Welfare post_Power bank manufacturer goes bankrupt_You pay for shipping_I will give you a brand new power bank board
Welfare post_Power bank manufacturer goes bankrupt_You pay for shipping_I will give you a brand new power bank board. The nationwide shipping fee is 10 yuan. Each person will receive 10 boards. If you...
ylyfxzsx Buy&Sell
What chips can be replaced for DAC8408F TI?
[i=s]This post was last edited by dontium on 2015-1-23 13:12[/i]I would like to ask TI's analog electronics experts what chips can be replaced for DAC8408F TI?DAC8408F is a 4-channel 8-bit COMS D/A co...
LM3SXX Analogue and Mixed Signal
Is there a way to crack the FPGA program?
Is there a risk of the FPGA program stored in EPCS being cracked? Is there any effective way to prevent the program from being cracked?...
wenhuawu FPGA/CPLD
[Let you see how small you are] Time goes back billions of years - 42 steps of the universe --- repost
[i=s] This post was last edited by tiankai001 on 2018-5-16 15:52 [/i] [size=5][b][color=#333333][font="]The universe we know is currently divided into 42 scales [/font][/color] [color=#333333][font="]...
tiankai001 Creative Market
Discussion on the method of sending serial data test packets
In serial data testing, a special test fixture is often used to introduce the test signal into the oscilloscope for measurement and analysis. At this time, the serial signal link to be tested is not i...
安_然 Test/Measurement
Find the design method of input current clamp
The current clamping method is to ask if the normal working state is 1ma, the current can pass normally, but if the current exceeds the specified current limit (taking 5ma as an example), it will be c...
leosky568 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 726  1050  1475  2059  2300  15  22  30  42  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号