EEWORLDEEWORLDEEWORLD

Part Number

Search

7461097

Description
terminals power element bush M6 16 pin
CategoryThe connector   
File Size209KB,3 Pages
ManufacturerAll Sensors
Environmental Compliance  
Download Datasheet Parametric Compare View All

7461097 Online Shopping

Suppliers Part Number Price MOQ In stock  
7461097 - - View Buy Now

7461097 Overview

terminals power element bush M6 16 pin

7461097 Parametric

Parameter NameAttribute value
ManufactureWurth Electronics
Product CategoryTerminals
RoHSYes
ProducHigh Current Terminals
Stud / Tab SizeM6
InsulatiNot Insulated
Contact PlatingTi
Contact MaterialCoppe
Termination StylePress Fi
Current Rating160 A
Mounting MethodPCB
Operating Temperature Range- 40 C to + 135 C
PackagingBulk
TypeBush
Dimensions: [mm]
detail B
Bevelled edge
0,3 ±0,2
around
5,08
3,5 ±0,2
Drillhole specification for PCB:
Drill hole specification for chemical surfaces
(
O
1,60
-0,03
Properties:
Properties
Material
Surface
Execution
Tightening Torque
Operating Temperature
Storage Conditions
Insertion Force
Extraction Force
1)
PCB Thickness min
0.5
-55 °C up to +150 °C
0 °C up to +40 °C, < 75% RH
40
30
1.6
3.2
N per Pin min.
N per Pin min.
mm
mm
Value
Brass
Tin
Press-Fit
Nm
Unit
Tol.
)
min. 0,10
O
1,475 ±0,05
2,54
5,08
sectional drawing A-A
A
9,5
M 3
4,0
6,0
min. 25µm copper max. 60µm
PCB Thickness max
1)
min. 24hours after
Press-Fit Process
Electrical Properties:
Drillhole specification for PCB:
Drill hole specification for HAL
Properties
Rated Current
Test conditions
@ 20 °C
I
R
Value
130
Unit
A
Tol.
max.
A
B
(
O
1,60
-0,03
)
min. 0,10
Packaging Properties:
Packaging
Bulk
O
1,45 ±0,05
q
7,0
max. 15µm Sn
min. 25µm copper max. 60µm
Scale - 2:1
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED
CHECKED
GENERAL TOLERANCE
PROJECTION
METHOD
DaMa
DESCRIPTION
WlW
DIN ISO 2768-1m
REDCUBE PRESS-FIT with internal
thread and full plain pin-plate WP-
BUFU
REVISION
STATUS
ORDER CODE
7461093
DATE (YYYY-MM-DD)
BUSINESS UNIT
PAGE
001.002
Valid
2017-10-19
eiCan
1/3
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.

7461097 Related Products

7461097 7461147 7461095 7461094 7461098 7461100 7461096 7461061 7461383
Description terminals power element bush M6 16 pin terminals power element M5 16 pin terminals power element bush M4 16 pin terminals pwr element threaded M3 shank 9 pin terminals pwr element threaded M6 shank 25 pin terminals pwr element threaded m10 shank 36 pin terminals pwr element threaded M4 shank 9 pin terminals power element bush m10 36 pin terminals pwr element threaded M5 shank 16 pin
Manufacture Wurth Electronics Wurth Electronics Wurth Electronics Wurth Electronics Wurth Electronics Wurth Electronics Wurth Electronics Wurth Electronics Wurth Electronics
Product Category Terminals Terminals Terminals Terminals Terminals Terminals Terminals Terminals Terminals
RoHS Yes Yes Yes Yes Yes Yes Yes Yes Yes
Produc High Current Terminals High Current Terminals High Current Terminals High Current Terminals High Current Terminals High Current Terminals High Current Terminals High Current Terminals High Current Terminals
Stud / Tab Size M6 M5 M4 M3 M6 M10 M4 M10 M5
Insulati Not Insulated Not Insulated Not Insulated Not Insulated Not Insulated Not Insulated Not Insulated Not Insulated Not Insulated
Contact Plating Ti Ti Ti Ti Ti Ti Ti Ti Ti
Contact Material Coppe Coppe Coppe Coppe Coppe Coppe Coppe Coppe Coppe
Termination Style Press Fi Press Fi Press Fi Press Fi Press Fi Press Fi Press Fi Press Fi Press Fi
Current Rating 160 A 160 A 160 A 90 A 250 A 360 A 90 A 360 A 160 A
Mounting Method PCB PCB PCB PCB PCB PCB PCB PCB PCB
Operating Temperature Range - 40 C to + 135 C - 40 C to + 135 C - 40 C to + 135 C - 40 C to + 135 C - 40 C to + 135 C - 40 C to + 135 C - 40 C to + 135 C - 40 C to + 135 C - 40 C to + 135 C
Packaging Bulk Bulk Bulk Bulk Bulk Bulk Bulk Bulk Bulk
Type Bush Bush Bush Shank Shank Shank Shank Bush Shank
51 minimum system board single panel suitable for school
Two jumpers, all pins are brought out + there is a download port next to the two buttons[b][color=#5E7384]This content is originally created by EEWORLD forum user [size=3]xutong[/size]. If you need to...
xutong 51mcu
The resistor behind the rectifier bridge of this power supply acts as
In the circuit below, what are the functions of the resistors connected behind the rectifier bridge and the three resistors in the red box? What do they mean and what are their main functions?...
kal9623287 Power technology
LM2576-ADJ Output Current Change
[i=s]This post was last edited by paulhyde on 2014-9-15 04:10[/i]I made a power supply using LM2576-ADJ, and the output current is 5.5A. When connected to a load, the current remains unchanged. Why? C...
cemabentengteng Electronics Design Contest
Getting started with op amps, first lesson, introducing a typical op amp circuit
[color=rgb(34,34,34)][backcolor=rgb(238, 238, 238)]As shown in the figure, this is a typical application circuit diagram provided by TI. Let me analyze the role of each component. [/backcolor][/color]...
gaoyang9992006 Analog electronics
Does the 430 MCU have no internal pull-up? I spent a whole night on a matrix keyboard.
The MCU I used originally had internal pull-up, which formed a fixed mindset....
prayer_hong Microcontroller MCU
0000-9999 counter
I have four integrated digital tubes with a common anode. I want to make a 0000-9999 counter. Because the digital tube is integrated, the seven pins a, b, c, d, e, f, dp are shared, so as long as any ...
hlwen MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2726  1208  1870  416  1787  55  25  38  9  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号