EUROLINE - DC/DC-Converter
RxxVxx-Series, 2 Watt, DIP24, 6kVDC Isolation (Dual Output)
Features
●
6kVDC Isolation
●
Efficiency to 80%
●
UL 94V-0 Package Material
●
Internal SMD Construction
●
MTTF up to 1.0 Million Hours
●
BS EN 60950 Certified
●
Fully Encapsulated
●
UL1950 E196683 Recognised
Selection Guide
5V, 12V Input types
Part Number
Nom. Input
Voltage
(VDC)
5
5
5
5
12
12
12
12
Output
Voltage
(VDC)
±5
±9
±12
±15
±5
±9
±12
±15
Output
Current
(mA)
±200
±111
±83
±67
±200
±111
±83
±67
Efficiency
(%)
74
76
77
78
78
81
82
82
Isolation
Capacitance
(pF)
1.8
1.9
2.0
2.1
1.9
2.0
2.1
2.2
DIP24
Package
Style
R05V05
R05V09
R05V12
R05V15
R12V05
R12V09
R12V12
R12V15
Absolute Maximum Ratings
Input Voltage V
IN
Short Circuit Duration
1)
Internal Power Dissipation
Lead Temperature 1.5 mm from Case for 10 seconds
05V types
12V types
7VDC
15VDC
1s
0.9W
300°C
Electrical Specifications
(measured at T
A
= 25°C, at nominal input voltage and rated output current unless otherwise specified)
Input Voltage Range V
IN
(continuous operation)
Output Voltage Accuracy (see tolerance envelope)
Line Regulation (highV
IN
to low V
IN
)
Load Regulation (10% load to rated load) (depending on the type)
Output Ripple (BW=DC to 20MHz, all output types)
Isolation Voltage (flash tested for 1 second)
Resistance (Viso = 500VDC)
Switching Frequency at Full Load (depending on the type)
Package Weight
Operating Temperature Range
Storage Temperature Range
Temperature Rise Above Ambient (all output types)
MTTF
2)
(depending on the type)
– 0°C
+25°C
+85°C
5V types
12V types
4.5VDC min. / 5.5VDC max.
10.8VDC min. / 13.2VDC max.
–7.5% min. / 10% max.
1.0% typ. / 1.0% of V
IN
6% min. / 12% max.
200mVp-p max.
6000VDC min.
10 GΩ min.
35kHz max.
7.5 g
0°C to +70°C
+50°C to +130°C
+32°C max.
89kHrs min. / 961kHrs max.
82kHrs min. / 747kHrs max.
62kHrs min. / 311kHrs max.
1).
Supply voltage must be discontinued at the end of the short circuit duration
2).
Calculated using MIL-HDBK-217F with nominal input voltage at full load.
EU 36
Updated: 6. Dec. 2001
www.recom-international.com
EUROLINE - DC/DC-Converter
RxxVxx-Series, 2 Watt, DIP24, Isolated (Dual Output)
Typical Characteristics, Tolerance Envelope and Derating Graph
R05Vxx
100
10
0509, 0512, 0515
80
60
0505
0505
Tolerance Envelope
+10%
+5%
V Nom.
Output Voltage
0
-5
-10
0
20
40
60
80
100
10%
50%
100%
Total Output Current (%)
Output Load Current (%)
0512
0515
0509
Typical L
oad Line
Deviation from Nominal (%)
5
+2,5%
– 2,5%
– 7,5%
Efficiency (%)
40
20
0
20
40
60
80
100
Total Output Current (%)
R12Vxx
100
1209, 1212, 1215
10
1215
1209
0
1212
-5
1205
-10
0
20
40
60
80
100
Total Output Current (%)
Temperature Derating Graph
4.0
Output Power (Watts)
3.0
2.0
1.0
0
Safe
Operating Area
Deviation from Nominal (%)
80
1205
60
40
20
0
20
40
60
80
100
5
Efficiency (%)
0
20
40
60
70
80
Total Output Current (%)
Ambient Temperature
°C
Package Style and Pinning (mm)
24 PIN DIP Package Style
NC NC
24 23
-V NC 0V NC +V
17 16 15 14 13
2.54
1 2
VIN GND
32.35
8 9 10 11 12
-V NC 0V NC +V
2.54
1.0ø+0.15/–0
Recommended Footprint Details
14.90
RxxVxx
RECOM
****
2.54
0.60
3.90 min.
2.16
0.50±0.05
15.24
0.25
16.95
11.40
www.recom-international.com
EU 37