ECONOLINE - DC/DC-Converter
RY-0505SCL/DCL Ser., 1W, SIP7, Regul., Current Limit Protection (Single & Dual Output)
Selection Guide
Part
Number
SIP 7
RY-0505SCL/DCL
RY-0512SCL/DCL
RY-0515SCL/DCL
RY-1205SCL/DCL
RY-1212SCL/DCL
RY-1215SCL/DCL
RY-2405SCL/DCL
RY-2412SCL/DCL
RY-2415SCL/DCL
Input
Voltage
(VDC)
5
5
5
12
12
12
24
24
24
Output
Voltage
(VDC)
5/±5
12/±12
15/±15
5/±5
12/±12
15/±15
5/±5
12/±12
15/±15
Ouput
Current
(mA)
200/±100
84/±42
67/±34
200/±100
84/±42
67/±34
200/±100
84/±42
67/±34
Input Current
Full Load
No Load
(mA)
350
330
322
141
134
132
67
66
66
20
32
32
10
15
15
6
6
6
Efficiency
(%)
57
61
62
59
62
63
62
63
63
Features
●
Internal SMD Technology
●
Short Circuit Protection: Current Limit
●
Isolation 1kVDC
●
No External Components Required
●
Regulated Output
●
UL94V-0 Package Material
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Input Voltage
Voltage Setpoint Accuracy
Temperature Coefficient
Short Circuit Protection
Input Filter
Line Voltage Regulation
Load Voltage Regulation (10% to 100% full load)
Ripple and Noise (20MHz BW)
Efficiency at Full Load
Isolation Voltage
Switching Frequency at Full Load
Operating Temperature
Storage Temperature
Capacitance
±10%
±2%
±0.03%/°C
Current Limit Protection
Capacitor Type
±0.5% max.
±0.5% max.
100mVp-p max.
50% min.
1.000VDC min.
100kHz min.
-25°C to +70°C (see Graph)
-55°C to +100°C
80pF max.
Output Power (Watts)
1.0
Safe Operating Area
0,5
0
-25
0
50
100
125
150
70
Operating Temperature ˚C
2.0
1.5
Package Style and Pinning (mm)
19.60
7.10
Single Output
Dual Output
7 PIN SIP Package and Recommended Footprint Details
3rd angle
projection
10.14
RY-0505DCL
RECOM
****
0.51 typ.
RY-0505SCL
RECOM
****
RY-0505DCL
RECOM
****
Pin Connections
Pin #
1
2
Single
+Vin
–Vin
–Vout
No Pin
+Vout
Dual
+Vin
–Vin
–Vout
Com
+Vout
3.81min.
2.54
0.51 typ.
1 2
5
7
1 2
5 6 7
5
6
7
1.00 ø+0.15/–0
2.54
0.9
2.0
0.25
1 2
5 6 7
1.00 ø+0.15/–0
2.54
15.24
2.54
2.54
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
EC 44
August 2002