EEWORLDEEWORLDEEWORLD

Part Number

Search

247XCXM-300R120VAC

Description
Off-Delay Relay, 3PDT, Momentary, 5000mW (Coil), 10A (Contact), 28VDC (Contact), 30s Adj Min, 300s Adj Max, AC Input, AC/DC Output, Through Hole-Straight Mount
CategoryMechanical and electronic products    relay   
File Size447KB,2 Pages
ManufacturerStruthers-Dunn
Download Datasheet Parametric View All

247XCXM-300R120VAC Overview

Off-Delay Relay, 3PDT, Momentary, 5000mW (Coil), 10A (Contact), 28VDC (Contact), 30s Adj Min, 300s Adj Max, AC Input, AC/DC Output, Through Hole-Straight Mount

247XCXM-300R120VAC Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC):102 V
Maximum adjustable time delay300 s
Minimum adjustable time delay30 s
body width37.2 mm
body height95.2 mm
Body length or diameter66.8 mm
Coil current (AC) maximum value0.042 A
Coil power5000 mW
Maximum coil voltage (AC)120 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load10A@240VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)240 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Manufacturer's serial number247
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
Maximum operating temperature70 °C
Minimum operating temperature-20 °C
physical size66.8mm X 37.2mm X 95.2mm
GuidelineCSA; UL
Relay actionMOMENTARY
Relay function3PDT
Relay typeOFF-DELAY RELAY
surface mountNO
Termination typeSOLDER
Base Number Matches1
246/247 Series - Timer Delay Relay
DPDT, 4PDT,6PST, 10 Amp
Rugged, industrial time delay versions of the popular 219 series. Contacts can be configured up
to four pole double throw or six pole single throw. Time ranges are adjustable over a 1:10 range.
Knob adjustment and integral hold down clip are standard. A large option list makes this product
easily customized for special applications.
E13224
GENERAL SPECIFICATIONS (@ 25° C)
Timing:
Functions Available
Time Range
Timing Adjustment
Timing Repeatability
(Constant voltage and temperature)
Reset Time maximum
Input Pulse Length minimum
Contacts:
Contact Configuration
Contact Material
Contact Rating
120 / 240VAC Resistive
28VDC Resistive
Motor 120VAC
Motor 240VAC
Minimum Contct Load
Contact Resistance, Initial
Coil:
Coils Available
Nominal Coil Power
Input Voltage Tolorance -AC
Input Voltage Tolorance -DC
Transient Protection
Reverse Polarity Protection
Duty
Dielectric Strength:
Across Open Contacts
Between Mutally Insulated Points
Insulation Resistance
Temperature:
Operating
Storage
Life Expectancy:
Electrical (full load operations)
Mechanical (no load operations)
Miscellaneous:
Mounting Position
Mating Socket
Accessories
Enclosure
Weight
On-delay, Off-delay
Up to 10 minutes
Knob
3%
150mS
50mS
DPDT, 4PDT, 6PST
Silver Alloy Gold Diffused
10 Amp / 5 Amp
10 Amp
-
-
500mW
100 milliohms max @ 6VDC, 1A
AC and DC
5VA 2.5W
85% to 110% of nominal
80% to 110% of nominal
Yes
Yes
Continuous
500Vrms
1500Vrms
1,000 Mohms min @ 500VDC
-20 to 70°C (-4 to 158°F)
-40 to 105°C (-40 to 221°F)
100,000
10,000,000
Any
12 pin =27390, 27390D
14 pin = 33377, 33377D
Hold down clip integral to relay
Clear Polycarbonate
8.6oz (244 grams)
with socket
Industrial Pin Out
Note: SM = Single make
DM = Double make
Voltage
Make
Carry
Resistive Inductive
120VAC
30 Amp 10 Amp 10 Amp
3 Amp
240VAC
30 Amp 10 Amp 5 Amp
1 Amp
24VDC
30 Amp 10 Amp 10 Amp
5 Amp
28VDC
30 Amp 10 Amp 10 Amp
3 Amp
125VDC
30 Amp 10 Amp 0.5 Amp
0.1 Amp
For versions with suffix “69” permant magnet blowouts
Voltage
Make
Carry
Resistive Inductive
125VDC (SM) 30 Amp 10 Amp 1.5 Amp
0.5 Amp
125VDC (DM) 30 Amp 10 Amp
4 Amp
1.5 Amp
250VDC (SM) 30 Amp 10 Amp
0.5 Amp 150 mAmp
250VDC (DM) 30 Amp 10 Amp 1.5 Amp
0.5 Amp
246/247 Contact Load Specifications
7/9
www.struthers-dunn.com
(843) 664-3303
What should I do if I connect multiple DS18B20s together and can read the signal if the wires are short, but cannot read the signal if the wires are long? [Solved]
[size=2]I connected multiple DS18B20s together and used the ROM search function to find the ID and then read the temperature separately. If the connection line (30cm) is short, it can be read. If the ...
SUNKE9 MCU
2013 Electronics Contest Questions
[i=s]This post was last edited by paulhyde on 2014-9-15 03:02[/i] If anyone can figure out the speed please upload it!!!!!!!!!!!!!!!!!!!!!!!! Thank you!!!...
love政广 Electronics Design Contest
What is the difference between RS232 and FPGA?
Is there any FPGA level standard that supports RS232 level standard, so there is no need for MAX232 to convert the level?...
wenhuawu FPGA/CPLD
How much power do headphones really need? (Part 1)
When we set out to create an op amp for a headphone application (we ended up choosing the OPA1622), the first problem we needed to solve was determining how much power the headphone would require. Thi...
maylove Analogue and Mixed Signal
Automatic gain AGC circuit
Automatic gain AGC circuit, if the analog front end AFE or the OP built into the MCU has this function, then there is no need to worry about OP saturation distortion or not being able to reach full sc...
QWE4562009 Test/Measurement
OrcadLibraryBuilder cannot generate schematic library
Hello experts: I just started using OrcadLibraryBuilder. When generating a schematic library, everything works fine. However, I cannot find the library file in the specified file directory. Everything...
swjql PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 535  2468  123  2134  951  11  50  3  43  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号