MOS FET Relays
Smallest Class in market, USOP
Package MOS FET Relays (C
OFF
(typical): 20 pF, R
ON
(typical): 1
Ω)
with
Low Output Capacitance and ON
Resistance (C
×
R = 20 pF
•
Ω)
in a 60-V
Load Voltage Model.
• ON resistance of 1
Ω
(typical) suppresses output signal
attenuation.
RoHS compliant
Note:
G3VM-61PR
The actual product is marked differently from the image
shown here.
■
Application Examples
• Semiconductor inspection tools
• Measurement devices
• Broadband systems
• Data loggers
■
List of Models
(Ask your OMRON representative for delivery times.)
Contact form
SPST-NO
Note:
Terminals
Surface-mounting
terminals
Load voltage (peak value)
(See note)
60 V
Model
G3VM-61PR
G3VM-61PR(TR)
Minimum packaging unit
Number per tape
---
1,500
1.
Ask your OMRON representative for orders under 1,500 pcs.
2.
Tape-cut USOPs are packaged without humidity resistance.
Use manual soldering to mount them. Refer to common precautions.
3.
The AC peak and DC value is given for the load voltages.
■
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
G3VM-61PR
3.25
2.05
0.15 1.65
(0.4)
Note:
A tolerance of
±0.2
mm applies
to all dimensions unless other-
wise specified.
Weight: 0.03 g
Note:
The actual product is marked differently
from the image shown here.
1.27
2.2
2.85
(0.35)
0.2
■
Terminal Arrangement/Internal Connections (Top View)
G3VM-61PR
4
3
932
The actual product is marked
differently from the image
shown here.
Beveled side is input side.
1
Pin 1
2
Pin 1
■
Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-61PR
0.85 2.9
0.8
1.27
G3VM-61PR
■
Absolute Maximum Ratings (Ta = 25°C)
Item
Input
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Output
Load voltage (AC peak / DC)
Continuous load current (AC peak / DC)
ON current reduction rate
Connection temperature
Dielectric strength between input and
output (See note 1.)
Ambient operating temperature
Storage temperature
Soldering temperature
I
F
∆
I
F
/°C
V
R
T
j
V
OFF
I
O
∆
I
O
/°C
T
j
V
I-O
T
a
T
stg
---
Symbol
50
−0.5
5
125
60
400
−4.0
125
500
−40
to +85
−40
to +125
260
Rating
mA
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
°C
°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Ta
≥
25°C
Ta
≥
25°C
Unit
Measurement Conditions
G3VM-61PR
Note:
1.
The dielectric strength be-
tween the input and out-
put was checked by
applying voltage between
all pins as a group on the
LED side and all pins as a
group on the light-receiv-
ing side.
■
Electrical Characteristics (Ta = 25°C)
Item
Input
LED forward voltage
Reverse current
Capacity between terminals
Trigger LED forward current
Output
Maximum resistance with output ON
Current leakage when the relay is open
Capacity between terminals
Capacity between I/O terminals
Insulation resistance between I/O terminals
Turn-ON time
Turn-OFF time
Symbol
V
F
I
R
C
T
I
FT
R
ON
I
LEAK
C
OFF
C
I-O
R
I-O
tON
tOFF
Mini-
mum
1.0
---
---
---
---
---
---
---
1,000
---
---
Typical
1.15
---
15
0.5
1.0
---
20
0.3
---
0.3
0.3
Maxi-
mum
1.3
10
---
3
1.5
1
30
---
---
0.5
0.5
V
µA
pF
mA
Ω
nA
pF
pF
MΩ
ms
ms
Unit
Measurement
conditions
I
F
= 10 mA
V
R
= 5 V
V = 0, f = 1 MHz
I
O
= 100 mA
I
F
= 5 mA, I
O
= 400 mA,
t<1s
V
OFF
= 60 V, Ta = 25°C
V = 0, f = 1 MHz,
t<1s
f = 1 MHz, Vs = 0 V
V
I-O
= 500 VDC,
RoH
≤
60%
I
F
= 5 mA, R
L
= 200
Ω,
V
DD
= 20 V (See note 2.)
V
OUT
I
F
Note:
2.
Turn-ON and Turn-OFF
Times
I
F
1
2
4
3
R
L
V
DD
V
OUT
10%
t
ON
90%
t
OFF
■
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Load voltage (AC peak / DC)
Operating LED forward current
Continuous load current (AC peak / DC)
Operating temperature
Symbol
V
DD
I
F
I
O
T
a
Minimum
---
5
---
−20
---
7.5
---
---
Typical
Maximum
48
20
400
65
V
mA
mA
°C
Unit
■
Engineering Data
Load Current vs. Ambient Temperature
G3VM-61PR
Load current (mA)
500
■
Safety Precautions
Refer to
“Common Precautions”
for all G3VM models.
400
300
200
100
0
−20
0
20
40
60
80
100
Ambient temperature (°C)