EEWORLDEEWORLDEEWORLD

Part Number

Search

123B12-C6P-02-HA

Description
Non-Linear Resistor
CategoryPassive components    The resistor   
File Size65KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

123B12-C6P-02-HA Overview

Non-Linear Resistor

123B12-C6P-02-HA Parametric

Parameter NameAttribute value
MakerCooper Industries
package instruction,
Reach Compliance Codeunknow
Base Number Matches1
Bussmann
®
SHORTSTOP
®
Auto, Manual & Modified Reset Circuit Protectors
Series 120
SPECIFICATIONS
Single Pole Thermal Type Breakers
Ratings:
8A to 50A; 12 VDC; 24 VDC.
Operating Temperature:
–10°F (–23°C) to 150°F (65°C).
Storage Temperature:
–20°F (–29°C) to 200°F (93°C).
Applications:
Battery chargers, trucks, buses, RV’s, trolling motors, etc.
Approvals:
Complies with SAE Standard J553.
TEMPERATURE DERATING CURVES
200%
% 0F RATED CURRENT
% 0F RATED CURRENT
150%
100%
50%
0%
-50º
Two 10-32 studs:
.66" (AUX); .56" (BAT)
.69"
(17.5)
Two 10-32 studs:
.56" (AUX & BAT)
.99"
(25.2)
.66"
(16.8)
TIME VS. PERCENT OF RATED CURRENT
600%
500%
400%
300%
200%
100%
0
5
10 15
20 30 40 100 200 500
TIME IN SECONDS
Terminal Options
.69"
(17.5)
.66"
(16.8)
.69"
(17.5)
.56"
(14.2)
A
B
.56"
(14.2)
50º 77º 100º 150º
200º
TEMPERATURE IN DEGREES F.
250º
C
D
.41"
(10.3)
Cover & Bracket Options
METAL COVER
1.24"
(31.5)
.79"
(20.1)
1.56"
(39.6)
.38" (9.6)
1.24"
(31.5)
.79"
(20.1)
PLASTIC COVER
1.27"
(32.3)
.83" 1.56"
(21.1) (39.6)
.62"
(15.7)
O Bracket
1.56"
(39.6)
.83"
1.27" (21.1)
(32.3)
A Bracket
.37" (9.4)
.37" (9.4)
Two 10-32 studs:
.66" (AUX & BAT)
.84"
(21.4)
.41"
(10.3)
Two .25" Q.C.
(AUX & BAT)
.69"
(17.5)
E
.56"
(14.2)
.41"
(10.3)
H
.56"
(14.2)
One .25" Q.C. (AUX);
One 10-32 stud (BAT)
.99"
(25.2)
.30"
(7.7)
Double .25" Q.C. (AUX);
One 10-32 stud (BAT)
.84"
(21.4)
.64"
(16.3)
O Bracket
.69"
(17.5)
A Bracket
.79"
1.24"
(31.5) (20.1)
1.27"
(32.2)
B Bracket
.12" (3.0)
dia. boss
1.27"
(32.2)
C Bracket
J
.41"
(10.3)
K
.83"
(21.1)
.54"
(13.7)
1.56"
(39.6)
.79"
(20.1)
1.24"
(31.5)
.69"
(17.5)
B Bracket
Double .25" Q.C. (AUX);
Single .25" Q.C. (BAT)
.69"
(17.5)
Two .25" Q.C. (AUX & BAT)
Perpendicular
Orientation
Reset button
.06"
(1.5)
.62"
(15.7)
1.27"
(32.3)
.83"
(21.1)
.38" (9.6)
1.56"
(39.6)
L
.37" (9.4)
.69"
(17.5)
C Bracket
Two 10-32 studs
(AUX & BAT)
.62" (15.7)
Ref. (Typ)
w/base attached
E Bracket
Series 123
O Bracket w/reset
PART NUMBERING SYSTEM
Series
Terminal
Rating
Bracket
Mtg. Holes
Cover*
Options
Hardware
1 2
ttt
t
tt
t
O – No bracket
A – Bracket
B – Bracket
C – Bracket
E – Bracket
(plastic only)
t
0 – No bracket
1 – .140 dia.
2 – .196 dia.
3 – .237 dia.
(metal only)
4 – .265 dia.
(plastic only)
5 – .228 dia.
(plastic only)
6 – .221 dia.
(metal only)
t
tt
tt
M – Metal
P – Plastic
01 – Waterproof
(metal
covers only)
02 – Splashproof
(optional on
metal covers -
add 02 suffix;
std. on plastic
covers - omit
02 suffix.)
WA – Whiz-lock nut
assembled
WB – Whiz-lock
nut bulk un-
assembled
HA – Nut & lock
washer
assembled
HB – Nut & lock
washer bulk
unassembled
KA – Keps lock nut
assembled
KB – Keps lock
nut bulk
unassembled
121 – Auto Reset
08 – 8 amps
A – Two 10-32 studs;
12 VDC
10 – 10 amps
.66 (Aux), .56 (Bat)
122 – Modified
12 – 12 amps
B – Two 10-32 studs;
12 VDC
15 – 15 amps
.56 (Aux & Bat)
123 – Manual
20 – 20 amps
C – Two 10-32 studs;
24 VDC
25 – 25 amps
.66 (Aux & Bat)
115 VAC
30 – 30 amps
***D – Two .250 QC;
124 – Auto
35 – 35 amps
(Aux & Bat)
24 VDC
***E – One .250 QC (Aux); 40 – 40 amps
125 – Modified
One 10-32 stud (Bat) 50 – 50 amps
24 VDC
** H – One 10-32 stud
.56 (Bat), Double
.250 QC (Aux)
***J – Single .250 QC (Bat)
Double .250 QC (Aux)
***K – Two .250 QC (Aux & Bat)
L – Two 10-32 studs; .37 (Aux & Bat)
* Series 123 available in plastic cover only. Series
122 & 125 available in metal cover only.
** 40A maximum
*** 30A maximum
12-16-98
SB98107 Rev. A
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies
of this BIF document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide
technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design
or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or
update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the
user in all possible applications.
Form No. 120 ShortStop
Page 1 of 1
BIF Document: 2067
[Mil MYD-YA15XC-T Review] + Use STM32CubeProgrammer software to update system firmware
The document provided by Mir 01_Documents\User_Manual\Chinese\Software Manual\MYD-YA15XC-T_Linux Software Development Guide V1.0.0.pdf Section 4 describes how to update the system firmware. The MYC-YA...
dql2016 Special Edition for Assessment Centres
Confusion about system interruption and physical interruption of registry
Today I looked at the external serial port ST16C2550 driver of Youlong and found some puzzling phenomena. In the registry, there are [HKEY_LOCAL_MACHINE\Drivers\BuiltIn\S16550_A] [color=#FF0000]"SysIn...
zxg1986516 Embedded System
The network transformer output does not connect to RJ45, but uses a custom interface!
I am working on a small project that requires Ethernet communication, but the DIY device end is not suitable for RJ45 network cable interface, and a customized aviation plug interface is required. So ...
燕园技术宅 Analog electronics
Survey | We can help you overcome the difficulties in motor drive!
For those who want to learn motor drive, a great opportunity is here~The popularity of motor drive is self-evident. EEWorld and Anqu Technology hope to provide you with some unique information and mak...
nmg Motor Drive Control(Motor Control)
Was this sentence translated incorrectly in history? (Napoleon's famous quote)
Original text: Let china sleep, when she awakens, the world will be sorry Translation: "China is a sleeping lion, and when she wakes up she shocks the world. Literal translation: Let China sleep, when...
kcl123 MCU
EVC compiles fine after using CDateTimeCtrl, but fails to run after downloading to the target machine
I used CDateTimeCtrl in EVC and it compiled fine, but it failed to run after downloading to the target machine. After removing the control, it can run. Please give me some advice....
ywlgjy Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2899  1237  65  439  1359  59  25  2  9  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号