EEWORLDEEWORLDEEWORLD

Part Number

Search

5-1415043-1

Description
general purpose relays pt78602
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size525KB,7 Pages
ManufacturerAll Sensors
Environmental Compliance  
Download Datasheet Parametric View All

5-1415043-1 Online Shopping

Suppliers Part Number Price MOQ In stock  
5-1415043-1 - - View Buy Now

5-1415043-1 Overview

general purpose relays pt78602

5-1415043-1 Parametric

Parameter NameAttribute value
ManufactureTE Connectivity
Product CategoryGeneral Purpose Relays
RoHSYes
PackagingBulk
General Purpose Relays
SCHRACK
Accessories Miniature Relay PT
n
n
n
n
n
Easy replacement of relays on a densely packed DIN rail
No reduction of protection class or creepage/clearance with
plastic retainer
Plug-in indicator- and protection modules
Retainer clip with ejection function for relays of 29 mm height
DIN-rail sockets and accessories: RoHS compliant (Directive
2002/95/EC)
F0263-F
Premium socket with screwless terminals for DIN rail mounting
PT 78 74P
Premium socket, logical terminal arrangement, 4 pole
PT 78 72P
Premium socket, logical terminal arrangement, 2 pole
n
n
n
n
n
n
n
PT 2/4 pole 6/12 A
Screwless Clamps
Mounting of solid wires without tool
Double Clamps per terminal
Jumper links for interconnection
Open coil circuit for active modules
Logical terminal arrangement
F0300-B
S0546-AE
Approvals
V
REG.-Nr. 115719,
Z
E135149
Technical data
2-pole
4-pole
Rated voltage / max. switching voltage AC
240 / 400 VAC
240 VAC
Rated current
12 A
6A
Limiting continuous current
see derating curve
Dielectric strength coil-contact circuit
2500 V
rms
2500 V
rms
open contact circuit
1200 V
rms
1200 V
rms
adjacent contact circuits
2500 V
rms
2000 V
rms
Clearance / creepage coil-contact circuit
W
4/4 mm
W
4/4 mm
adjacent contact circuits
W
3.5/9.5 mm
W1.8/3.5
mm
Material group of insulation parts
IIIa
Insulation to IEC 60664-1
Type of insulation coil-contact circuit
basic
open contact circuit
functional
adjacent contact circuits
basic
Rated insulation voltage
250 V
Pollution degree
2
1)
Rated voltage system
230 / 400 V
Overvoltage category
III
1
)
with inserted relay pollution degree 1 in region
of contact pins / socket inlets
.
1
Datasheet 2010/11
www.tycoelectronics.com
www.schrackrelays.com
© 2010 Tyco Electronics Ltd.
Rev. JK1
Datasheets and product specification acc.
IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Datasheets and product data is subject to
the terms of the disclaimer and all chapters
of the ‘Definitions’ section, available at
http://relays.tycoelectronics.com/definitions
Datasheets, product data, ‘Definitions’
section, application notes and all
specifications are subject to change.
Other members of Keithley 2400 Series Digital SourceMeter
If your application requires a wider source or measurement range than the 2401 SourceMeter Instrument [1] can provide, then other instruments in the 2400 Series [2] may provide the range you need. Ref...
Jack_ma Test/Measurement
[Very practical] Hands-on teaching of circuit board debugging skills
[p=null, 2, left][color=rgb(51, 51, 51)][font=-apple-system-font, BlinkMacSystemFont, "][size=17px]Debugging is a must for junior electronic engineers at the primary stage! So I have combined several ...
btty038 Analog electronics
Srio input clock configuration
In our application, the srio clock of 6678 is given externally. In this case, is it meaningful to write the input clock to the prescalar_srv_clk register? When is this register useful? Can 6678 set th...
YUCHAO DSP and ARM Processors
Practical Information 3 - Review of Five Short-Range Wireless Interconnect Technologies
Five short-range wireless connection technologies are becoming the focus of discussion in the industry. They are wireless LAN (Wi-Fi), Bluetooth, ZigBee, Ultra WideBand and NFC. As wireless connection...
1234 RF/Wirelessly
The kind of reference book you need when you have problems at work
A few days ago, someone sent me a message after observing the forum for a while. He thought I could write a book, a reference book to guide the younger students who just graduated from school.After se...
quanzx Analog electronics
I would like to ask some questions about developing programs under the wince6.0 ebox2300 platform
Recently, I have been developing an application on the eBox2300 platform under WinCE6.0 system, using VS2005 as the development environment and C++ as the development language. Can anyone with develop...
bin8888 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2513  2653  936  1336  619  51  54  19  27  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号