LXN1240-6M1G

Description
din rail power supplies 500w X-din-rail converters sngl out
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size628KB,21 Pages
ManufacturerPower-One (bel)
Websitehttps://belfuse.com/
Environmental Compliance  
Download Datasheet Parametric Compare View All

LXN1240-6M1G Online Shopping

Suppliers Part Number Price MOQ In stock  
LXN1240-6M1G - - View Buy Now

LXN1240-6M1G Overview

din rail power supplies 500w X-din-rail converters sngl out

LXN1240-6M1G Parametric

Parameter NameAttribute value
ManufacturePower-One
Product CategoryDIN Rail Power Supplies
RoHSYes
ProducSwitching Supplies
Output Power Rating458 W
Input Voltage264 VAC, 350 VDC
Number of Outputs1
Output Voltage-Channel 127.3 V
Output Current-Channel 116.8 A
Dimensions113.6 mm L x 194 mm W
Isolation Voltage2.8 kV
Mounting StyleDIN Rail
Open Frame/EnclosedEnclosed
Output TypeIsolated
®
X Series Data Sheet
375, 500 Watt AC-DC and DC-DC DIN-Rail Converters
Features
• RoHS lead-free-solder and lead-solder-exempted
products are available
• Rugged 35 mm DIN-rail snap-fit design
• Class I equipment
• Universal AC-input with single stage conversion AC to
DC or DC input of 90 to 350 V
• Power factor correction, harmonics IEC/EN 61000-3-2
• Virtually no inrush current
• Immunity to IEC/EN 61000-4-2, -3, -4, -5, -6, -11
• Emissions according to EN 55011/022
• Very high efficiency; up to 89%
• Short-term output peak power capability, rectangular
current limiting characteristic
• Single or two independently regulated outputs with 24,
36, or 48 V
• Outputs no-load, overload, and short-circuit proof
• PCBs protected by lacquer
• Very high reliability
138
5.43"
194
7.64"
Safety according to IEC/EN 50178, IEC 61010-1, IEC
60950-1, UL/CSA 60950-1 2
nd
Ed.
114
4.49"
Description
The Convert Select front end series represents a family of
DIN-rail mountable AC-DC and DC-DC converters with power
factor correction. The converters have been designed
according to the latest industry requirements and standards.
They are ideal for use in outdoor and other demanding
applications to power building control systems, factory
automation, industrial controls, instrumentation, electro-
magnetic drives, fans, and other DC loads. Different models
are available with a single output or two independently
regulated, electrically isolated outputs with 24, 36, or 48 V.
Special models for battery charging are available.
Key features of the Convert Select line include power factor
correction with low harmonic distortion, negligibly low inrush
current, high immunity to transients and surges, and low
electromagnetic emissions. Internal protection circuits such as
input over- and undervoltage lockout, thermal protection, as
well as output overvoltage protection by a second control loop
ensure safe operation of the final system.
The outputs deliver an electrically-isolated Safety Extra Low
Voltage, SELV, (except models LXR/LXN1740) and low output
noise. They are no-load, overload, and short-circuit proof. The
electronically controlled short-term peak power capability of up
to 150% of the rated output power enables the front end
converters to deliver additional power to start-up motors or to
safely operate subsequent circuit breakers. Built-in large sized
output capacitors absorb possible reverse energy, which may
be caused by quick deceleration of electromagnetic drives
connected directly to the output. A green LED at the front cover
displays the status of the output(s).
The Convert Select Series was designed according to all
relevant international safety standards. The converters are
approved by TÜV and UL, and are UL 508 listed. Adequate
clearances and creepage distances allow operation in pollution
degree 3 environment (with AC input). All board assemblies are
coated with a protective lacquer.
Table of Contents
Page
Page
Immunity to Environmental Conditions ............................ 13
Mechanical Data ............................................................... 14
Safety and Installation Instructions .................................. 15
Description of Options ..................................................... 17
Accessories ...................................................................... 20
Description ......................................................................... 1
Model Selection .................................................................. 2
Functional Description ....................................................... 4
Electrical Input Data ........................................................... 5
Electrical Output Data ......................................................... 7
Electromagnetic Compatibility (EMC) .............................. 12
BCD20021-G Rev AC1, 13-May-2013
Page 1 of 21
www.power-one.com

LXN1240-6M1G Related Products

LXN1240-6M1G LXR1740-6M1G LXR1801-6G LXN2660-6 LXN1801-6 LXN1601-6 LXR1801-6 LXR1601-6G LXN1801-6K2
Description din rail power supplies 500w X-din-rail converters sngl out din rail power supplies 375w X-din-rail converters sngl out din rail power supplies 375w X-din-rail converters sngl out din rail 494w 2X 24.7V din rail 494w 49.4V din rail 494w 24.7V din rail 371w 49.4V din rail power supplies 375w X-din-rail converters sngl out din rail power supplies 48v AC-DC converter W/system connector
(Repost) Anan: As an engineer, we feel sad and helpless
Whenever I see old engineers who have worked for seven, eight, or even ten years come for interviews or job fairs , I feel embarrassed and uncomfortable, and I always naturally think: In a few years, ...
ddllxxrr Talking
Profibus Test 5(PBT5) 手持式测试仪在浆纸厂的应用
[align=center][color=rgb(0, 0, 0)][font=punctuation, Microsoft YaHei, Tohoma]Guangzhou Hongke Technology Department[color=#26709a][url=mailto:support@hkaco.com]support@hkaco.com[/url][/color][/font][/...
hongkeanny Industrial Control Electronics
Can 430 generate a 150KHZ sine wave using the internal DA?
Can 430X16X use the internal DA to generate a 150KHZ sine wave? Is 150KHZ too high? If you use the table lookup method to sample 10 points, it will take 1.5M....
wangfei890912 Microcontroller MCU
Questions about the output settings of 9B96's LDO
The LDO output of versions below the 9000 series is configurable, such as the 8962. Especially when using PLL, the LDO output must be set to 2.75V, otherwise there may be problems. In the 9000 series,...
yytdragon Microcontroller MCU
Difference between STM32 and LPC1768
A few months ago, I learned the following because I needed to use ARM for some projects, which are LPC1768 and LPC1769 series. I found that these C programs still operate on registers , which is simil...
whgwuhan NXP MCU
How to get the current working path of vxworks?
I want to ask you experts, I copied my application file (a.out) and vxworks image (vxworks) to D:\MyFile of the target machine. Then I want to use getcwd() (note: get current working directory) to get...
happyjinwen Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 191  1549  8  172  2495  4  32  1  51  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号