EEWORLDEEWORLDEEWORLD

Part Number

Search

FTSH-126-02-G-D-EP

Description
Board Connector, 52 Contact(s), 2 Row(s), Male, Straight, 0.05 inch Pitch, Solder Terminal, Guide Pin, Black Insulator,
CategoryThe connector    The connector   
File Size327KB,3 Pages
ManufacturerSAMTEC
Websitehttp://www.samtec.com/
Environmental Compliance  
Download Datasheet Parametric View All

FTSH-126-02-G-D-EP Overview

Board Connector, 52 Contact(s), 2 Row(s), Male, Straight, 0.05 inch Pitch, Solder Terminal, Guide Pin, Black Insulator,

FTSH-126-02-G-D-EP Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1389903198
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL9.15
subject depth0.178 inch
Connector typeBOARD CONNECTOR
Contact to complete cooperationGOLD (10)
Contact completed and terminatedGold (Au)
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
DIN complianceNO
Filter functionNO
IEC complianceNO
Insulator colorBLACK
insulator materialLIQUID CRYSTAL POLYMER
JESD-609 codee4
MIL complianceNO
Plug contact pitch0.05 inch
Match contact row spacing0.05 inch
Mixed contactsNO
Installation option 1GUIDE PIN
Installation option 2LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
OptionsGENERAL PURPOSE
PCB contact patternRECTANGULAR
PCB contact row spacing1.27 mm
Plating thickness10u inch
polarization keyPOLARIZED HOUSING
Rated current (signal)3.3 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.09 inch
Terminal pitch1.27 mm
Termination typeSOLDER
Total number of contacts52
UL Flammability Code94V-0
REVISION BX
DO NOT
SCALE FROM
THIS PRINT
NOTES:
1.
C
REPRESENTS A CRITICAL DIMENSION.
No OF POSITIONS
2. PARTS MAY BE CUT TO POSITION.
-02 THRU -50
3. MAXIMUM CUT FLASH: .010[0.25] ON TAIL SIDE, ALL OTHER AREAS
(PER ROW)
AT .015[0.38]. LOOSE CUT FLASH MUST BE REMOVED.
4. MINIMUM PUSHOUT FORCE: 1.0 LB.
LEAD STYLE
5. TERMINALS TO BE SHEARED TO MEET DIMENSION SPECIFICATION.
-01: .120 [3.05]
6. LAYER PACKAGE 2 - 4 POSITIONS AND TUBE 5 - 50 POSITIONS.
-02: .075 [1.91]
7. MAXIMUM BURR ALLOWANCE: .003[0.08].
-03: .065 [1.65]
8. DUE TO THE HIGH AMOUNT OF INSERTION FORCE NEEDED, THE -EC OPTION
-04: .150 [3.81]
IS NOT COMPATIBLE WITH AUTO PLACEMENT. SAMTEC RECOMMENDS
MANUAL PLACEMENT FOR ALL ASSEMBLIES WITH THE -EC OPTION.
9. MAXIMUM HEIGHT VARIATION BETWEEN ROWS: .005[0.13].
PLATING SPECIFICATION
10. VOIDS MAY OR MAY NOT BE PRESENT ON POSITIONS 5 THROUGH 8
AND CAN BE MIXED WITHIN AN ORDER.
-G:10µ" GOLD IN CONTACT AREA,
3µ" GOLD ON TAIL
-F: 3µ" FLASH SELECTIVE GOLD IN CONTACT
AREA, MATTE TIN ON TAIL
(No OF POS x .0500[1.270])
+.005
[
+0.13
]
-.010 -0.25
-L: 10µ" LIGHT SELECTIVE GOLD IN CONTACT
AREA, MATTE TIN ON TAIL
(No OF POS x .0500[1.270]) - .0500[1.270]
-S: 30µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
-H: 30µ" HEAVY GOLD IN CONTACT AREA,
50
02
3µ" GOLD ON TAIL
-FM: 3µ" FLASH SELECTIVE GOLD IN CONTACT
AREA, MATTE TIN ON TAIL
.135 3.43
-LM: 10µ" LIGHT SELECTIVE GOLD IN CONTACT
AREA, MATTE TIN TAIL
REF
-SM: 30µ" SELECTIVE GOLD IN CONTACT AREA,
MATTE TIN ON TAIL
-LTL: 10µ" LIGHT GOLD IN CONACT AREA,
49
TIN/LEAD (90%/10 +/-5%) ON TAIL
01
FTSH-1XX-XX-XXX-D-XXX-XX
OPTIONS
-ES: END SHROUDS (SEE FIG 2, SHT 2)
(MOLDED 5 POS MIN; -02 & -03 LEAD STYLE ONLY)
(MUST USE FTSH-XX-ES-XX-X)
(SNAP SHROUDS 9 POS MIN; -02 & -03 LEAD STYLE ONLY)
(MUST USE FTSH-50-D)
-EJ: EJECTOR SHROUDS: (SEE FIG 3, SHT 2)
(10 POS MIN; -01 LEAD STYLE ONLY)
(MUST USE FTSH-50-D)
-EC: LOCKING CLIP (SEE FIG 4, SHT 2; SEE NOTE 8)
(9 POS MIN; -02 & -03 LEAD STYLES ONLY)
(MUST USE FTSH-50-D)
-EP: GUIDE POST (SEE FIG 5, SHT 2)
(9 POS MIN; -02 & -03 LEAD STYLES ONLY)
(USE ONLY WHEN MATING WITH CLP)
(MUST USE FTSH-50-D)
-EL: BOARD LOCKS (SEE FIG 6, SHT 2)
(9 POS MIN; -02 & -03 LEAD STYLES ONLY)
(USE ONLY WHEN MATING WITH CLP)
(MUST USE FTSH-50-D)
-K: KEYING OPTION FOR MATING WITH FFSD
(05 THRU 25 ONLY)
(POSITION 13, 17, 20 & 25 AVAILABLE WITH -EJ OPTION)
(LEAD STYLE -01 ONLY, SEE FIG 7, SHT 3)
(MUST USE FTSH-XX-CN-XX)
-LC: LOCKING CLIP: (SEE FIG 8, SHT 3)
(5 POS MIN, ONLY AVAILABLE IN -01 LEAD STYLE)
(IN COMBINATION WITH -K, USE FTSH-XX-CN-XX,
10 POSITION MINIMUM, ONLY AVAILABLE IN
-01 LEAD STYLE)
(MUST USE FTSH-50-D)
(SINGLE MATING CYCLE ONLY)
(MUST BE MATED TO SAMTEC FFSD SERIES)
FTSH-50-D
ROW SPECIFICATION
-D: DOUBLE ROW
POLARIZING OPTION
XXX INDICATES POSITION TO BE OMITTED
(NOT AVAILABLE WITH EX OPTIONS)
(ONLY AVAILABLE WITH -F, -FM, -L, -LM PLATING OPTIONS)
.0160 0.406 SQ
REF (TYP)
2 MAX SWAY
(EITHER DIRECTION)
C
.050 1.27
2 MAX SWAY
(EITHER DIRECTION)
.070 1.78 REF
(CONTACT AREA)
"A"
(SEE TABLE 1)
(SEE NOTE 9)
C
T-1S15-XX-XXX
SEE TABLE 1
"A"
(SEE TABLE 1)
(SEE NOTE 9)
"C" REF
(SEE TABLE 1)
.099 2.51
"B"
(SEE TABLE 2)
(SEE NOTES 5 & 7)
SEE NOTE 3
(2 PLCS)
FIG 1
2 MAX SWAY
(EITHER DIRECTION)
IN-PROCESS
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
*
PROPRIETARY NOTE
*
THIS DOCUMENT CONTAINS CONFIDENTIAL AND
PROPRIETARY INFORMATION AND ALL DESIGN,
MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS
AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC,
INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE
OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR
REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY
OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS
WRITTEN CONSENT OF SAMTEC, INC.
.XX: .01 [.3]
1
.XXX: .005 [.13]
.XXXX: .0010 [.025]
ANGLES
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail info@SAMTEC.com
code 55322
DESCRIPTION:
DWG. NO.
MATERIAL:
DO NOT SCALE DRAWING
SHEET SCALE: 5:1
INSULATOR: LCD UL 94-V0
TERMINAL: PHOSPHOR BRONZE
.050 x .050 CL THROUGH HOLE TERMINAL STRIP
FTSH-1XX-XX-XXX-D-XXX-XX
02/27/1996
SHEET
1
OF
3
F:\DWG\MISC\MKTG\FTSH-1XX-XX-XXX-D-XXX-XX-MKT.SLDDRW
BY:
J. FERRY
Fujitsu FM3 Multi-Function Serial Port (MFS) Sample Code
The multi-function serial port (MFS) of Fujitsu FM3 is very powerful and flexible in application. For details, please see my previous post "MB9B506R Multi-function Serial Interface" . The negative fac...
yang.aiquan DIY/Open Source Hardware
TI samples cannot be applied for (forum activity)
Have you ever encountered the problem shown in the screenshot below? When applying for a sample, it always prompts that you cannot apply for a free chip and ask you to choose to purchase the chip. How...
hanskying666 TI Technology Forum
pads2007
Looking for PADS2007 layout tutorial...
tiro PCB Design
MSP430F5438A serial port sending cannot be started
MSP430F5438A serial port transmission cannot be started. I have checked the settings countless times and compared them with the routines. There is no problem, but the serial port transmission cannot b...
易成书 Microcontroller MCU
Wow, I just drank Nongfu Spring this morning~~~
[b]The water quality of Qiandao Lake, the source of Nongfu Spring water, is said to be only suitable for industrial use[/b] The water quality of Qiandao Lake is Class IV. Is the water source of Nongfu...
绿茶 Talking
What does transparent transmission in communication networks mean?
1. Transparent transmission: refers to a data transmission method that is independent of the medium, modulation and demodulation method, transmission method, and transmission protocol of the transmiss...
蓝先生 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 358  1476  1868  2203  1635  8  30  38  45  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号