SHORTSTOP
®
Auto, Manual & Modified Reset Circuit Protectors
Series 120
SPECIFICATIONS
Single Pole Thermal Type Breakers
Ratings:
8A to 50A; 12 VDC; 24 VDC.
Operating Temperature:
–10°F (–23°C) to 150°F (65°C).
Storage Temperature:
–20°F (–29°C) to 200°F (93°C).
Applications:
Battery chargers, trucks, buses, RV’s, trolling motors, etc.
Approvals:
Complies with SAE Standard J553.
TEMPERATURE DERATING CURVES
200%
% 0F RATED CURRENT
% 0F RATED CURRENT
150%
100%
50%
0%
-50º
Two 10-32 studs:
.66" (AUX); .56" (BAT)
.69"
(17.5)
Two 10-32 studs:
.56" (AUX & BAT)
.99"
(25.2)
.66"
(16.8)
TIME VS. PERCENT OF RATED CURRENT
600%
500%
400%
300%
200%
100%
0
5
10 15
20 30 40 100 200 500
TIME IN SECONDS
Terminal Options
.69"
(17.5)
.66"
(16.8)
.69"
(17.5)
.56"
(14.2)
A
B
.56"
(14.2)
50º 77º 100º 150º
200º
TEMPERATURE IN DEGREES F.
250º
C
D
.41"
(10.3)
Cover & Bracket Options
METAL COVER
1.24"
(31.5)
.79"
(20.1)
1.56"
(39.6)
.38" (9.6)
1.24"
(31.5)
.79"
(20.1)
PLASTIC COVER
1.27"
(32.3)
.83" 1.56"
(21.1) (39.6)
.62"
(15.7)
O Bracket
1.56"
(39.6)
.83"
1.27" (21.1)
(32.3)
A Bracket
.37" (9.4)
.37" (9.4)
Two 10-32 studs:
.66" (AUX & BAT)
.84"
(21.4)
.41"
(10.3)
Two .25" Q.C.
(AUX & BAT)
.69"
(17.5)
E
.56"
(14.2)
.41"
(10.3)
H
.56"
(14.2)
One .25" Q.C. (AUX);
One 10-32 stud (BAT)
.99"
(25.2)
.30"
(7.7)
Double .25" Q.C. (AUX);
One 10-32 stud (BAT)
.84"
(21.4)
.64"
(16.3)
O Bracket
.69"
(17.5)
A Bracket
.79"
1.24"
(31.5) (20.1)
1.27"
(32.2)
B Bracket
.12" (3.0)
dia. boss
1.27"
(32.2)
C Bracket
J
.41"
(10.3)
K
.83"
(21.1)
.54"
(13.7)
1.56"
(39.6)
.79"
(20.1)
1.24"
(31.5)
.69"
(17.5)
B Bracket
Double .25" Q.C. (AUX);
Single .25" Q.C. (BAT)
.69"
(17.5)
Two .25" Q.C. (AUX & BAT)
Perpendicular
Orientation
Reset button
.06"
(1.5)
.62"
(15.7)
1.27"
(32.3)
.83"
(21.1)
.38" (9.6)
1.56"
(39.6)
L
.37" (9.4)
.69"
(17.5)
C Bracket
Two 10-32 studs
(AUX & BAT)
.62" (15.7)
Ref. (Typ)
w/base attached
E Bracket
Series 123
O Bracket w/reset
PART NUMBERING SYSTEM
Series
Terminal
Rating
Bracket
Mtg. Holes
Cover*
Options
Hardware
1 2
ttt
t
tt
t
O – No bracket
A – Bracket
B – Bracket
C – Bracket
E – Bracket
(plastic only)
t
0 – No bracket
1 – .140 dia.
2 – .196 dia.
3 – .237 dia.
(metal only)
4 – .265 dia.
(plastic only)
5 – .228 dia.
(plastic only)
6 – .221 dia.
(metal only)
t
tt
tt
M – Metal
P – Plastic
01 – Waterproof
(metal
covers only)
02 – Splashproof
(optional on
metal covers -
add 02 suffix;
std. on plastic
covers - omit
02 suffix.)
WA – Whiz-lock nut
assembled
WB – Whiz-lock
nut bulk un-
assembled
HA – Nut & lock
washer
assembled
HB – Nut & lock
washer bulk
unassembled
KA – Keps lock nut
assembled
KB – Keps lock
nut bulk
unassembled
121 – Auto Reset
08 – 8 amps
A – Two 10-32 studs;
12 VDC
10 – 10 amps
.66 (Aux), .56 (Bat)
122 – Modified
12 – 12 amps
B – Two 10-32 studs;
12 VDC
15 – 15 amps
.56 (Aux & Bat)
123 – Manual
20 – 20 amps
C – Two 10-32 studs;
24 VDC
25 – 25 amps
.66 (Aux & Bat)
115 VAC
30 – 30 amps
***D – Two .250 QC;
124 – Auto
35 – 35 amps
(Aux & Bat)
24 VDC
***E – One .250 QC (Aux); 40 – 40 amps
125 – Modified
One 10-32 stud (Bat) 50 – 50 amps
24 VDC
** H – One 10-32 stud
.56 (Bat), Double
.250 QC (Aux)
***J – Single .250 QC (Bat)
Double .250 QC (Aux)
***K – Two .250 QC (Aux & Bat)
L – Two 10-32 studs; .37 (Aux & Bat)
* Series 123 available in plastic cover only. Series
122 & 125 available in metal cover only.
** 40A maximum
*** 30A maximum
12-16-98
SB98107 Rev. A
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies
of this BIF document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide
technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design
or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or
update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the
user in all possible applications.
Form No. 120 ShortStop
Page 1 of 1
BIF Document: 2067
S3C6410 DRAM Controller
We replaced the DRAM in the project, so we needed to reconfigure the DRAM controller of S3C6410 . It turned out that the DRAM controller in S3C6410 is quite complicated.S3C6410 supports two DRAM chip ...
jmh Industrial Control Electronics
Electronic scale locks the digital tube display weight?
[color=#252525]Hello masters! I used STC12LE5A60S2 microcontroller and HX711 to write an electronic scale program. I want to lock the weight displayed on the digital tube by pressing a button once, an...
fbzsn 51mcu
Question about the MMI_TEXT.h file in the MTK standard development package
In the _MMI_TEXT_ID_E enumeration variable in this file, the change of the defined ID order will affect the final compilation result. However, I did not find any special usage, and they are all used a...
qiujinjin Embedded System
The experience of learning Easy Power Supply is tragic
Tragic ~ Only 80 points ~ SIMPLE SWITCHER power modules not only provide strong system performance, but also low EMI and high reliability, suitable for today's cutting-edge 3G/HD/SD broadcast video eq...
hangsky Analogue and Mixed Signal
【Chuanglong TL570x-EVM】Review 04 - CAN Test
【Chuanglong TL570x-EVM】Evaluation 0 4 - CAN Test 1. I personally use the CANPro analyzer, produced by Chuangxin Technology Co., Ltd., a dual-channel CAN.2. Evaluation Board CAN Settings Enter the eval...
小火苗 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 165  1311  431  1985  2563  4  27  9  40  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号