M5294-000006-035BC

Description
Pressure Sensor
CategoryThe sensor   
File Size299KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

M5294-000006-035BC Overview

Pressure Sensor

M5294-000006-035BC Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145012561951
Reach Compliance Codeunknown
YTEOL7.3
Maximum accuracy(%)0.25%
Other featuresIP 66, REVERSE POLARITY PROTECTION, SHORT CIRCUIT PROTECTION
shellSTAINLESS STEEL
Maximum working current5 mA
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
Output range0.5-4.5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port type1/8-27 NPT
Maximum pressure range507.63 Psi
Minimum pressure range-1 Psi
Pressure sensing modeCOMPOUND
Response time2000 µs
Sensor/temperature sensor typePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage30 V
Minimum supply voltage5 V
Termination typeCONNECTOR
M5200
Industrial Pressure Transducer
SPECIFICATIONS
Wide Temperature Range
Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless-Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Compound
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.25% Accuracy
±1.0% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The M5200
pressure transducers from the Microfused line of MEAS,
with their modular design, offer maximum flexibility for different
configurations. This latest series sets a new price performance
standard for demanding commercial and heavy industrial applications.
This series is suitable for measurement of liquid or gas pressure, even
for difficult media such as contaminated water, steam, and mildly
corrosive fluids.
The wetted material is made of either 17-4 PH or 316L stainless steel
and the transducer’s durability is excellent with no welds or organics
exposed to the pressure media. The M5200 is weatherproof and
exceeds the latest heavy industrial CE requirements including surge
protection. The circuit is protected from reverse wiring at input and
short circuit at output.
This product is geared to the OEM customer for low to mid volumes.
MEAS stands ready to provide a custom design of the M5200 where
the volume and application warrants. Additional configurations not
listed are either available or possible. Please inquire for further
information.
APPLICATIONS
Industrial Process Control and Monitoring
Advanced HVAC Systems
Refrigeration Systems
Automotive Test Stands
Off-Road Vehicles
Pumps and Compressors
Hydraulic/Pneumatic Systems
Agriculture Equipment
Energy Generation and Management
SENSOR SOLUTIONS
///M5200
08/2020
Page 1
See the question below. What method of communication is used?
[backcolor=rgb(222, 240, 251)]To control 30 points (temperature, switch), the lower computer has not been built yet, the position of each point varies from 10 meters to 100 meters, the construction pa...
caoqing DIY/Open Source Hardware
Can the stream driver be written like this in wince?
BPH_Init( LPCVOID pBusContext ) { //Startup animation PROCESS_INFORMATION processInformation; HMODULE hinstance = LoadLibrary(TEXT("Coredll.dll")); FARPROC pFuc = GetProcAddress(hinstance,(L"CreatePro...
bookworm Embedded System
E13C diesel engine helps Hino Profia achieve 2015 fuel efficiency standards ahead of schedule
Hino Motors will soon launch a large truck "Hino Profia " that meets the "2015 fuel efficiency standards " in some grades. The fuel efficiency standards have been implemented since April 1, 2006, and ...
frozenviolet Automotive Electronics
Why do low-frequency voltage sources generally not consider internal resistance, while high-frequency voltage sources such as 2M-30M generally have an internal resistance of 50 ohms?
Why do low-frequency voltage sources generally not consider internal resistance, while high-frequency voltage sources such as 2M-30M generally have an internal resistance of 50 ohms?...
secondlife110 RF/Wirelessly
Please give me some guidance!!!
I am new to DSP and I took a program developed by someone else, CCS3.1. After compiling it, 25 errors appeared. These 25 errors are all in the Configuration1cfg.s62 file. For example, "Configuration1c...
追日成风 DSP and ARM Processors
The salary thing... After watching it, I feel mixed emotions... Fight hard, loser
[i=s] This post was last edited by aibing on 2014-12-25 14:33 [/i] Salary list of 112 IT companies: Huawei is the first, Alibaba is the fourth 2014/10/13 8:52:00 The author is a 2013 graduate of Xidia...
aibing Recruitment

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2339  2044  2115  648  950  48  42  43  14  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号