EEWORLDEEWORLDEEWORLD

Part Number

Search

D2F-01L10

Description
basic / snap action switches subminiature basic switch
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size638KB,8 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric View All

D2F-01L10 Online Shopping

Suppliers Part Number Price MOQ In stock  
D2F-01L10 - - View Buy Now

D2F-01L10 Overview

basic / snap action switches subminiature basic switch

D2F-01L10 Parametric

Parameter NameAttribute value
ManufactureOm
Product CategoryBasic / Snap Action Switches
RoHSYes
Operating Force0.5 N
Factory Pack Quantity150
Snap Action Switch
D2F
Subminiature Snap Action Switch
• Switches 3 A loads (general-purpose), 1 A loads
(low force general-purpose) and 0.1 A loads(microvoltage/
microcurrent)
• Long life span assured by high-precision dual spring
reverse-action mechanism
• Flux penetration prevented by using an insert terminal and
allowing a height difference at the case bottom
• Ideal for a wide range of applications including appliances,
office equipment, audio and communications equipment
• RoHS Compliant
Ordering Information
Actuator
Contact
type
Model
Contact Model
OF
Terminal type
PCB
Pin plunger Microvoltage/ Low force 75 g
current
Standard 150 g
General-
purpose
Low force 75 g
Standard
150 g
D2F-01F
D2F-01
D2F-F
D2F
D2F-01FL
D2F-01L
D2F-FL
D2F-L
D2F-01FL3
D2F-01L3
D2F-FL3
D2F-L3
D2F-01FL2
D2F-01L2
D2F-FL2
D2F-L2
Self-
supporting
D2F-01F-T
D2F-01-T
D2F-F-T
D2F-T
D2F-01FL-T
D2F-01L-T
D2F-FL-T
D2F-L-T
D2F-01FL3-T
D2F-01L3-T
D2F-FL3-T
D2F-L3-T
D2F-01FL2-T
D2F-01L2-T
D2F-FL2-T
D2F-L2-T
Solder
D2F-01F-D3
D2F-01-D3
D2F-F-D3
D2F-D3
D2F-01L-D3
D2F-FL-D3
D2F-L-D3
D2F-01L3-D3
D2F-FL3-D3
D2F-L3-D3
D2F-01L2-D3
D2F-FL2-D3
D2F-L2-D3
Compact
Solder
D2F-01F-D
D2F-01-D
D2F-F-D
D2F-D
D2F-01L-D
D2F-FL-D
D2F-L-D
D2F-01L3-D
D2F-FL3-D
D2F-L3-D
D2F-01L2-D
D2F-FL2-D
D2F-L2-D
Right-angle
D2F-01F-A
D2F-01-A
D2F-F-A
D2F-A
D2F-01FL-A
D2F-01L-A
D2F-FL-A
D2F-L-A
D2F-01L3-A
D2F-FL3-A
D2F-L3-A
D2F-01L2-A
D2F-FL2-A
D2F-L2-A
Left-angle
D2F-01F-A1
D2F-01-A1
D2F-F-A1
D2F-A1
D2F-01FL-A1
D2F-01L-A1
D2F-FL-A1
D2F-L-A1
D2F-01L3-A1
D2F-FL3-A1
D2F-L3-A1
D2F-01L2-A1
D2F-FL2-A1
D2F-L2-A1
Hinge lever Microvoltage/ Low force 25 g
current
Standard 80 g
General-
purpose
Simulated
roller lever
Low force 25 g
Standard
80 g
D2F-01FL-D3 D2F-01FL-D
Microvoltage/ Low force 40 g
current
Standard 80 g
General-
purpose
Low force 40 g
Standard
80 g
D2F-01FL3-D3 D2F-01FL3-D D2F-01FL3-A D2F-01FL3-A1
Roller lever Microvoltage/ Low force 40 g
current
Standard 80 g
General-
purpose
Low force 40 g
Standard
80 g
D2F-01FL2-D3 D2F-01FL2-D D2F-01FL2-A D2F-01FL2-A1
Model Number Legend
D2F-
1 2 3 4
1.
Ratings
None: General loads
01:
Micro loads (0.1 A at 30 VDC)
3.
Actuator
4.
None: Pin plunger
L:
Hinge lever
L2:
Hinge roller lever
L3:
Simulated roller lever
Terminals
None: PCB terminals/straight terminals
-T:
Self-clinching PCB terminals
-A:
Right-angled PCB terminals
-A1: Left-angled PCB terminals
-D3: Solder terminals
-D:
Compact solder terminals
2.
Maximum Operating Force
None: 1.47 N {150 gf}
F:
0.74 N {75 gf}
Note:
These OF
values
are for the pin plunger models.
Snap Action Switch
D2F
31
Training institution, the latest and most personal tutorials from Friendly 2440 - Home of Development Board
[img=579,308]http://i.namipan.com/files/3fd9fab36f5b594ca72b3f9a38ea40d7e635c6dd7c4801009b6f/0/1.jpg[/img] There are five stages in total, the first one will be released first. Phase 1 (Application Pr...
麦麦 Embedded System
Differences between different models when STM32 multi-ADC alternately samples
I often hear that current microcontrollers integrate multiple ADC cores. By configuring the trigger time of different ADCs, alternate sampling of multiple ADCs can be achieved to increase the sampling...
littleshrimp stm32/stm8
Comparison of the advantages of digital cameras and analog cameras in machine vision system design
Machine vision is widely used in many fields such as automatic quality inspection, process control, parameter measurement and automatic assembly. In these systems, the camera is a key component that d...
朗锐智科 Energy Infrastructure?
What does (*(unsigned char volatile far *)(reg_addr) mean in keil?
I saw someone use this in keil, which is to assign a value to a register with an absolute address, but I don't understand how to interpret the two pointers in front. Can an expert help me explain it? ...
navyin Embedded System
Computing power going Platinum
[i=s] 本帖最后由 dontium 于 2015-1-23 13:40 编辑 [/i]IntroductionThe 80 PLUS? and Climate Savers Computing? initiativeshave set a very aggressive efficiency standard forputer power supplies. The “Platinum” le...
安_然 Analogue and Mixed Signal
Computer parallel port directly drives splc501 12864 black and white LCD
本帖来源: [url=http://www.avr32.cn/]http://www.avr32.cn/[/url] [url=http://www.avr32.cn/NGW100-AVR32-AT32AP7000/2010/01/24/p2.html][/url] [img]http://www.avr32.cn/files/2010/01/p1050386.jpg[/img] [img]htt...
aeiou Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1678  2873  1409  2515  2195  34  58  29  51  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号