• Industry standard design with switching currents of 10A to 21A
• Widely used for applications where long life expectancy and
high reliability is required.
• Choose from a variety of levers, terminals and operating forces.
• Right and Left Barrier options are available for the V-21 and
V-16 models
• Heat resistant versions of the V-15 and V-10 are available.
• RoHS Compliant
Ordering Information
■
Model Number Legend
V-
1 2 3
1.
-
4 5 6 7
-
8
-
9
4. Contact Form
COM Terminal, Bottom position:
1:
SPDT
2:
SPST-NC
3:
SPST-NO
COM Terminal, Side position:
4:
SPDT
5:
SPST-NC
6:
5.
SPST-NO
9.
7.
Maximum Operating Force
6:
400 gf
5:
200 gf
4:
100 gf
Note:
These OF
values
are for
the pin plunger models.
Ratings
21:
21 A at 250
VAC
16:
16 A at 250
VAC
15:
15 A at 250
VAC
11:
11 A at 250
VAC
10:
10 A at 250
VAC
Contact Gap
None: 1 mm (F gap)
G:
0.5 mm (G gap)
Actuator
None: Pin plunger
1:
Short hinge lever
2:
Hinge lever
3:
Long hinge lever
4:
Simulated roller lever
5:
Short hinge roller lever
6:
Hinge roller lever
2.
8.
Special Purpose
None: Standard
T:
Heat resistive
(V-15 and
V-10,
only)
Mounting Hole Size
None: 3.1 mm
K:
2.9 mm
3.
Terminals
A:
Solder terminals
C2:
Quick-connect terminal (#187)
C:
Quick-connect terminal (#250)
6. Insulation Barrier
None:
Without
Barrier
R:
Right-hand
barrier
L:
Left-hand
barrier
(Barriers available for
V-21
and
V-16,
only)
Note:
Consult Omron regarding nomenclature combinations and part numbers
not found in this datasheet.
Snap Action Switch
V
121
■
Available Combinations
Thermoplastic case
Model
Rated Current
OF
COM
Insulation
Heat
terminal
Barrier Resistance Terminal Symbol
position
Bottom
No
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Heat
resistant
(150°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Yes
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Side
No
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Note: 1.
❍:
Available model.
Consult OMRON for specific models with standard approval.
V-21
21 A
400 gf
V-16
16 A
400 gf
200 gf
V-11
11 A
100 gf
Thermosetting case
V-15
15 A
400 gf
200 gf
V-10
10 A
200 gf
100 gf
---
---
❍
---
---
---
---
---
❍
---
---
❍
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
---
---
---
---
---
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
■
List of Models
Thermoplastic Case
21 A (OF: 400 gf)
Without barrier
Common
terminal Contact
position form
Bottom
SPDT
SPST-NC
SPST-NO
SPDT
Right-hand barrier
Without barrier
Left-hand barrier
Terminal style Actuator
Quick-connect
(#250) (C)
V-21-1C6
V-21-1CR6
V-21-2CR6
V-21-3CR6
V-211-1CR6
V-212-1CR6
V-213-1CR6
V-214-1CR6
V-215-1CR6
V-216-1CR6
V-21-1CL6
V-21-2CL6
V-21-3CL6
V-211-1CL6
V-212-1C6
V-213-1CL6
V-214-1CL6
V-215-1CL6
V-216-1CL6
V-21-2C6
V-21-3C6
V-211-1C6
V-212-1C6
V-213-1C6
V-214-1C6
V-215-1C6
V-216-1C6
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Example: V-21G2-1C6-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
122
Snap Action Switch
V
16 A (OF: 200 gf)
Without barrier
Common
terminal Contact
position form
Bottom
SPDT
Right-hand barrier
Without barrier
Left-hand barrier
SPST-NC
SPST-NO
SPDT
Terminal style
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
V-16-1A5
V-16-1C25
V-16-1C5
V-16-2A5
V-16-2C25
V-16-2C5
V-16-3A5
V-16-3C25
V-16-3C5
V-161-1A5
V-161-1C25
V-161-1C5
V-162-1A5
V-162-1C25
V-162-1C5
V-163-1A5
V-163-1C25
V-163-1C5
V-164-1A5
V-164-1C25
V-164-1C5
V-165-1A5
V-165-1C25
V-165-1C5
V-166-1A5
V-166-1C25
V-166-1C5
V-16-1AR5
V-16-1C2R5
---
V-16-2AR5
V-16-2C2R5
---
V-16-3AR5
V-16-3C2R5
---
V-161-1AR5
V-161-1C2R5
---
V-162-1AR5
V-162-1C2R5
---
V-163-1AR5
V-163-1C2R5
---
V-164-1AR5
V-164-1C2R5
---
V-165-1AR5
V-165-1C2R5
---
V-166-1AR5
V-166-1C2R5
---
V-16-1AL5
V-16-1C2L5
---
V-16-2AL5
V-16-2C2L5
---
V-16-3AL5
V-16-3C2L5
---
V-161-1AL5
V-161-1C2L5
---
V-162-1AL5
V-162-1C2L5
---
V-163-1AL5
V-163-1C2L5
---
V-164-1AL5
V-164-1C2L5
---
V-165-1AL5
V-165-1C2L5
---
V-166-1AL5
V-166-1C2L5
---
11 A (OF: 100 gf)
Without barrier
Common
terminal
position
Bottom
Contact form
SPDT
Terminal style
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
V-11-1A4
V-11-1C24
V-11-1C4
V-111-1A4
V-111-1C24
V-111-1C4
V-112-1A4
V-112-1C24
V-112-1C4
V-113-1A4
V-113-1C24
V-113-1C4
V-114-1A4
V-114-1C24
V-114-1C4
V-115-1A4
V-115-1C24
V-115-1C4
V-116-1A4
V-116-1C24
V-116-1C4
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Examples: 1) V-16G3-1C25-K 2) V-11G-1A4-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
Snap Action Switch
V
123
Thermosetting Case
Standard models - 15 A / 10 A
Common Contact
terminal
form
position
Bottom
SPDT
Terminal style
A
C2
C
A
C2
A
C2
C
A
Actuator
15 A
200 gf
200 gf
V-10G-1A5-K
V-10G-1C25-K
—
V-10G-2A5-K
V-10G-2C25-K
V-10G-3A5-K
V-10G-3C25-K
—
V-10G-4A5-K
V-10G-5A5-K
V-10G-6A5-K
V-10G1-1A5-K
V-10G1-1C25-K
V-10G2-1A5-K
V-10G2-1C25-K
V-10G3-1A5-K
V-10G3-1C25-K
V-10G4-1A5-K
V-10G4-1C25-K
V-10G5-1A5-K
V-10G5-1C25-K
V-10G6-1A5-K
—
V-15G-1A5-K
V-15G-1C25-K
V-15G-1C5-K
V-15G-2A5-K
V-15G-2C25-K
V-15G-3A5-K
V-15G-3C25-K
V-15G-3C5-K
V-15G-4A5-K
V-15G-5A5-K
V-15G-6A5-K
V-15G1-1A5-K
V-15G1-1C25-K
V-15G2-1A5-K
V-15G2-1C25-K
V-15G3-1A5-K
V-15G3-1C25-K
V-15G4-1A5-K
V-15G4-1C25-K
V-15G5-1A5-K
V-15G5-1C25-K
V-15G6-1A5-K
V-15G6-1C25-K
10 A
100 gf
V-10G-1A4-K
V-10G-1C24-K
—
V-10G-2A4-K
V-10G-2C24-K
V-10G-3A4-K
V-10G-3C24-K
—
V-10G-4A4-K
V-10G-5A4-K
V-10G-6A4-K
V-10G1-1A4-K
V-10G1-1C24-K
V-10G2-1A4-K
V-10G2-1C24-K
V-10G3-1A4-K
V-10G3-1C24-K
V-10G4-1A4-K
V-10G4-1C24-K
V-10G5-1A4-K
V-10G5-1C24-K
V-10G6-1A4-K
V-10G6-1C24-K
Pin plunger
SPST-NC
SPST-NO
Side
Bottom
SPDT
SPST-NC
SPST-NO
SPDT
A
C2
A
C2
A
C2
A
C2
A
C2
A
C2
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
For SPST-NC and SPST-NO with levers consult Omron.
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
Heat Resistant Models (Up to 150°C) - 15 A / 10A
Common
terminal
position
Bottom
Contact
form
SPDT
Terminal style
Solder Terminals
(A)
Actuator
15 A
200 gf
V-15-1A5-T
V-151-1A5-T
V-152-1A5-T
V-153-1A5-T
V-154-1A5-T
V-155-1A5-T
V-156-1A5-T
10 A
100 gf
V-10-1A4-T
V-101-1A4-T
V-102-1A4-T
V-103-1A4-T
V-104-1A4-T
V-105-1A4-T
V-106-1A4-T
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Add “C2” to the part number in the appropriate location to obtain versions with #187 quick-
connect terminals. Example: 1) V-15G1-1C25-T-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
124
Snap Action Switch
V
Specifications
■
Ratings
(reference values)
Type
Rated voltage
Non-inductive load
Resistive load
Lamp load
NC
NO
NC
NO
21 A
3A
21 A
5A
14 A
5A
0.6 A
0.1 A
0.3 A
0.05 A
16 A
2A
16 A
4A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
15 A
2A
15 A
4A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
11 A
1.5 A
11 A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
1.5 A
10 A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
Inductive load
Inductive load
Motor load
NC
NO
NC
NO
12 A
4A
12 A
7A
12 A
5A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
3A
10 A
6A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
3A
10 A
6A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
6A
2A
6A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
6A
2A
6A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
V-21
V-16
V-15
V-11
V-10
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
Note: 1.
The above current values are the normal current values of models with a contact gap of 1 mm (gap F), which vary with the normal current
values of models with a contact gap of 0.5 mm (gap G).
2.
Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3.
Lamp load has an inrush current of 10 times the steady-state current.
4.
Motor load has an inrush current of 6 times the steady-state current.
5.
The ratings values apply under the following test conditions: Ambient temperature: 20±2°C, Ambient humidity: 65±5%, Operating frequency: 30 operations/min
■
Approved Standards
UL1054 (File No. E41515)
CSA C22.2 No.55 (File No. LR21642)
Rated voltage
125 VAC
250 VAC
125 VDC
250 VDC
V-21
21 A, 1/2 HP
V-16
16 A, 1/2 HP
V-15
15 A, 1/2 HP
0.6 A
0.3 A
V-11
11 A, 1/3 HP
V-10
10 A, 1/3 HP
EN 61058-1 (File No. 129608, VDE approval)
Rated voltage
250 VAC
V-21
20 (4) A
V-16
16 (4) A
V-11
11 (3) A
EN 61058-1 (File No. T9451451, TÜV Rheinland approval)
Rated voltage
250 VAC
250 VDC
V-15
15 A
0.3 A
V-10
10 A
Testing conditions: 5E4 (50,000 operations), T105 (0°C to 105°C)
Testing conditions: 5E4 (50,000 operations), T85 (0°C to
[size=4] 1. Introduction [/size] [size=4] my country has a population of nearly 1.3 billion. Food safety has been a challenging issue and social hotspot in recent years [1-3]. With the rapid developme...
I used VS2005 MFC to develop an MTML file browser. I used the Microsoft web browser control. It can be compiled normally. When I put it into a WINCE5.0 machine, it cannot be started. The error message...
In digital signal processing, especially in communication signal processing applications, complex multipliers are often encountered. Some friends may feel strange, the signals are all real signals, wh...
I have just started to engage in technological innovation activities recently. I want to make a wheeled transport robot. I wonder if anyone has information to share with me. I will be very grateful! !...
A line scan lens is an industrial lens used with line scan cameras. Its imaging principle is to capture the image of the workpiece using a linear sensor and then perform digital signal processing t...[Details]
To enable real-time monitoring of home security and automatically dial a number for voice prompts or send text messages when an alarm occurs, a GPRS-based embedded telephone alarm system was design...[Details]
A parallel inverter consists of two thyristors (T1 and T2), a capacitor, a center-tapped transformer, and an inductor. The thyristors provide a current path, while the inductor L maintains a consta...[Details]
In recent years, many people have switched to new energy vehicles, and this type of vehicle has indeed been highly sought after and is considered the future direction of automobile development, and...[Details]
Ever since the Tesla fire incident, electric cars, already known for their poor reputation, have been subjected to even more scathing criticism. Despite this, many people are still willing to buy t...[Details]
According to foreign media reports, researchers at the University of Surrey have developed an artificial intelligence system that can accurately locate the location of equipment in densely populate...[Details]
Recently, AstroBo Robot, a subsidiary of Chenxing Automation, launched a new mobile collaborative palletizing product. Leveraging an omnidirectional mobile chassis, an intelligent scheduling system...[Details]
Electric vehicles are powered by electricity, and charging is a device that supplements the vehicle's energy source. It is common to need to recharge the vehicle when driving. But can you charge th...[Details]
UPS stands for Uninterruptible Power Supply, which includes energy storage devices. It is mainly used to provide uninterruptible power supply for devices that require high power stability.
...[Details]
The MCX E series is the most reliability- and safety-focused series in NXP's extensive MCX product portfolio.
With the launch of this series, NXP has further enriched its 5V-compatible MCU pr...[Details]
A tubular motor is an electric motor that is typically used to control the movement of machines and equipment. Tubular motors are generally divided into two categories: linear tubular motors and ro...[Details]
In the period after the switching power supply achieved the "20 kHz" revolution in the 1970s, although improvements and enhancements were made in circuit technology, the development level of the se...[Details]
Shenzhen Baowei Power Supply high frequency pure sine wave power, communication inverter power supply has two communication interfaces, RS232 and R485 interfaces, their functions and characteristic...[Details]
HTTP is the abbreviation of Hypertext Transfer Protocol. It is an application protocol based on TCP/IP communication protocol used to transmit HTML and image files. It is an application-level objec...[Details]
A scale, a large, ground-mounted scale, is typically used to measure the tonnage of truck cargo. It's the primary weighing device used in factories, mines, and businesses for bulk cargo measurement...[Details]