• Industry standard design with switching currents of 10A to 21A
• Widely used for applications where long life expectancy and
high reliability is required.
• Choose from a variety of levers, terminals and operating forces.
• Right and Left Barrier options are available for the V-21 and
V-16 models
• Heat resistant versions of the V-15 and V-10 are available.
• RoHS Compliant
Ordering Information
■
Model Number Legend
V-
1 2 3
1.
-
4 5 6 7
-
8
-
9
4. Contact Form
COM Terminal, Bottom position:
1:
SPDT
2:
SPST-NC
3:
SPST-NO
COM Terminal, Side position:
4:
SPDT
5:
SPST-NC
6:
5.
SPST-NO
9.
7.
Maximum Operating Force
6:
400 gf
5:
200 gf
4:
100 gf
Note:
These OF
values
are for
the pin plunger models.
Ratings
21:
21 A at 250
VAC
16:
16 A at 250
VAC
15:
15 A at 250
VAC
11:
11 A at 250
VAC
10:
10 A at 250
VAC
Contact Gap
None: 1 mm (F gap)
G:
0.5 mm (G gap)
Actuator
None: Pin plunger
1:
Short hinge lever
2:
Hinge lever
3:
Long hinge lever
4:
Simulated roller lever
5:
Short hinge roller lever
6:
Hinge roller lever
2.
8.
Special Purpose
None: Standard
T:
Heat resistive
(V-15 and
V-10,
only)
Mounting Hole Size
None: 3.1 mm
K:
2.9 mm
3.
Terminals
A:
Solder terminals
C2:
Quick-connect terminal (#187)
C:
Quick-connect terminal (#250)
6. Insulation Barrier
None:
Without
Barrier
R:
Right-hand
barrier
L:
Left-hand
barrier
(Barriers available for
V-21
and
V-16,
only)
Note:
Consult Omron regarding nomenclature combinations and part numbers
not found in this datasheet.
Snap Action Switch
V
121
■
Available Combinations
Thermoplastic case
Model
Rated Current
OF
COM
Insulation
Heat
terminal
Barrier Resistance Terminal Symbol
position
Bottom
No
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Heat
resistant
(150°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Yes
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Side
No
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Note: 1.
❍:
Available model.
Consult OMRON for specific models with standard approval.
V-21
21 A
400 gf
V-16
16 A
400 gf
200 gf
V-11
11 A
100 gf
Thermosetting case
V-15
15 A
400 gf
200 gf
V-10
10 A
200 gf
100 gf
---
---
❍
---
---
---
---
---
❍
---
---
❍
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
---
---
---
---
---
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
■
List of Models
Thermoplastic Case
21 A (OF: 400 gf)
Without barrier
Common
terminal Contact
position form
Bottom
SPDT
SPST-NC
SPST-NO
SPDT
Right-hand barrier
Without barrier
Left-hand barrier
Terminal style Actuator
Quick-connect
(#250) (C)
V-21-1C6
V-21-1CR6
V-21-2CR6
V-21-3CR6
V-211-1CR6
V-212-1CR6
V-213-1CR6
V-214-1CR6
V-215-1CR6
V-216-1CR6
V-21-1CL6
V-21-2CL6
V-21-3CL6
V-211-1CL6
V-212-1C6
V-213-1CL6
V-214-1CL6
V-215-1CL6
V-216-1CL6
V-21-2C6
V-21-3C6
V-211-1C6
V-212-1C6
V-213-1C6
V-214-1C6
V-215-1C6
V-216-1C6
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Example: V-21G2-1C6-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
122
Snap Action Switch
V
16 A (OF: 200 gf)
Without barrier
Common
terminal Contact
position form
Bottom
SPDT
Right-hand barrier
Without barrier
Left-hand barrier
SPST-NC
SPST-NO
SPDT
Terminal style
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
V-16-1A5
V-16-1C25
V-16-1C5
V-16-2A5
V-16-2C25
V-16-2C5
V-16-3A5
V-16-3C25
V-16-3C5
V-161-1A5
V-161-1C25
V-161-1C5
V-162-1A5
V-162-1C25
V-162-1C5
V-163-1A5
V-163-1C25
V-163-1C5
V-164-1A5
V-164-1C25
V-164-1C5
V-165-1A5
V-165-1C25
V-165-1C5
V-166-1A5
V-166-1C25
V-166-1C5
V-16-1AR5
V-16-1C2R5
---
V-16-2AR5
V-16-2C2R5
---
V-16-3AR5
V-16-3C2R5
---
V-161-1AR5
V-161-1C2R5
---
V-162-1AR5
V-162-1C2R5
---
V-163-1AR5
V-163-1C2R5
---
V-164-1AR5
V-164-1C2R5
---
V-165-1AR5
V-165-1C2R5
---
V-166-1AR5
V-166-1C2R5
---
V-16-1AL5
V-16-1C2L5
---
V-16-2AL5
V-16-2C2L5
---
V-16-3AL5
V-16-3C2L5
---
V-161-1AL5
V-161-1C2L5
---
V-162-1AL5
V-162-1C2L5
---
V-163-1AL5
V-163-1C2L5
---
V-164-1AL5
V-164-1C2L5
---
V-165-1AL5
V-165-1C2L5
---
V-166-1AL5
V-166-1C2L5
---
11 A (OF: 100 gf)
Without barrier
Common
terminal
position
Bottom
Contact form
SPDT
Terminal style
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
V-11-1A4
V-11-1C24
V-11-1C4
V-111-1A4
V-111-1C24
V-111-1C4
V-112-1A4
V-112-1C24
V-112-1C4
V-113-1A4
V-113-1C24
V-113-1C4
V-114-1A4
V-114-1C24
V-114-1C4
V-115-1A4
V-115-1C24
V-115-1C4
V-116-1A4
V-116-1C24
V-116-1C4
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Examples: 1) V-16G3-1C25-K 2) V-11G-1A4-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
Snap Action Switch
V
123
Thermosetting Case
Standard models - 15 A / 10 A
Common Contact
terminal
form
position
Bottom
SPDT
Terminal style
A
C2
C
A
C2
A
C2
C
A
Actuator
15 A
200 gf
200 gf
V-10G-1A5-K
V-10G-1C25-K
—
V-10G-2A5-K
V-10G-2C25-K
V-10G-3A5-K
V-10G-3C25-K
—
V-10G-4A5-K
V-10G-5A5-K
V-10G-6A5-K
V-10G1-1A5-K
V-10G1-1C25-K
V-10G2-1A5-K
V-10G2-1C25-K
V-10G3-1A5-K
V-10G3-1C25-K
V-10G4-1A5-K
V-10G4-1C25-K
V-10G5-1A5-K
V-10G5-1C25-K
V-10G6-1A5-K
—
V-15G-1A5-K
V-15G-1C25-K
V-15G-1C5-K
V-15G-2A5-K
V-15G-2C25-K
V-15G-3A5-K
V-15G-3C25-K
V-15G-3C5-K
V-15G-4A5-K
V-15G-5A5-K
V-15G-6A5-K
V-15G1-1A5-K
V-15G1-1C25-K
V-15G2-1A5-K
V-15G2-1C25-K
V-15G3-1A5-K
V-15G3-1C25-K
V-15G4-1A5-K
V-15G4-1C25-K
V-15G5-1A5-K
V-15G5-1C25-K
V-15G6-1A5-K
V-15G6-1C25-K
10 A
100 gf
V-10G-1A4-K
V-10G-1C24-K
—
V-10G-2A4-K
V-10G-2C24-K
V-10G-3A4-K
V-10G-3C24-K
—
V-10G-4A4-K
V-10G-5A4-K
V-10G-6A4-K
V-10G1-1A4-K
V-10G1-1C24-K
V-10G2-1A4-K
V-10G2-1C24-K
V-10G3-1A4-K
V-10G3-1C24-K
V-10G4-1A4-K
V-10G4-1C24-K
V-10G5-1A4-K
V-10G5-1C24-K
V-10G6-1A4-K
V-10G6-1C24-K
Pin plunger
SPST-NC
SPST-NO
Side
Bottom
SPDT
SPST-NC
SPST-NO
SPDT
A
C2
A
C2
A
C2
A
C2
A
C2
A
C2
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
For SPST-NC and SPST-NO with levers consult Omron.
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
Heat Resistant Models (Up to 150°C) - 15 A / 10A
Common
terminal
position
Bottom
Contact
form
SPDT
Terminal style
Solder Terminals
(A)
Actuator
15 A
200 gf
V-15-1A5-T
V-151-1A5-T
V-152-1A5-T
V-153-1A5-T
V-154-1A5-T
V-155-1A5-T
V-156-1A5-T
10 A
100 gf
V-10-1A4-T
V-101-1A4-T
V-102-1A4-T
V-103-1A4-T
V-104-1A4-T
V-105-1A4-T
V-106-1A4-T
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Add “C2” to the part number in the appropriate location to obtain versions with #187 quick-
connect terminals. Example: 1) V-15G1-1C25-T-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
124
Snap Action Switch
V
Specifications
■
Ratings
(reference values)
Type
Rated voltage
Non-inductive load
Resistive load
Lamp load
NC
NO
NC
NO
21 A
3A
21 A
5A
14 A
5A
0.6 A
0.1 A
0.3 A
0.05 A
16 A
2A
16 A
4A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
15 A
2A
15 A
4A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
11 A
1.5 A
11 A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
1.5 A
10 A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
Inductive load
Inductive load
Motor load
NC
NO
NC
NO
12 A
4A
12 A
7A
12 A
5A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
3A
10 A
6A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
3A
10 A
6A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
6A
2A
6A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
6A
2A
6A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
V-21
V-16
V-15
V-11
V-10
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
Note: 1.
The above current values are the normal current values of models with a contact gap of 1 mm (gap F), which vary with the normal current
values of models with a contact gap of 0.5 mm (gap G).
2.
Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3.
Lamp load has an inrush current of 10 times the steady-state current.
4.
Motor load has an inrush current of 6 times the steady-state current.
5.
The ratings values apply under the following test conditions: Ambient temperature: 20±2°C, Ambient humidity: 65±5%, Operating frequency: 30 operations/min
■
Approved Standards
UL1054 (File No. E41515)
CSA C22.2 No.55 (File No. LR21642)
Rated voltage
125 VAC
250 VAC
125 VDC
250 VDC
V-21
21 A, 1/2 HP
V-16
16 A, 1/2 HP
V-15
15 A, 1/2 HP
0.6 A
0.3 A
V-11
11 A, 1/3 HP
V-10
10 A, 1/3 HP
EN 61058-1 (File No. 129608, VDE approval)
Rated voltage
250 VAC
V-21
20 (4) A
V-16
16 (4) A
V-11
11 (3) A
EN 61058-1 (File No. T9451451, TÜV Rheinland approval)
Rated voltage
250 VAC
250 VDC
V-15
15 A
0.3 A
V-10
10 A
Testing conditions: 5E4 (50,000 operations), T105 (0°C to 105°C)
Testing conditions: 5E4 (50,000 operations), T85 (0°C to
In Zigbee networking, there are often some networking errors. For binding communication, some NV saved information may cause the nodes to be unable to communicate. At this time, we need to erase some ...
Ask everyone a question: ------------------------------- I am doing embedded development on the board. When in kernel mode: float result = 5.4 / 4.3 ; // I have a simple question. Some people say that...
First of all, why does C++ need inheritance? What does inheritance mean? What are the three types of inheritance?
Why do we need inheritance?
When writing large programs, there are often many classes,...
I don't understand the circuit. This amplifier circuit cannot achieve the signal amplification function. I don't understand the first level. I would be grateful if you can help me....
The Southchip SC8905 EVM evaluation data contains a setting tool that can easily set the registers on the control board and read the setting data of the registers. The following is the interface of th...
The definition statements in the .h file of an STM32 file are: #define LED_SEG0 PBout(0) #define LED_SEG1 PBout(1) . . . . #define LED_SEG15 PBout(15) The values assigned in its .c file are: LED_SEG0=...
The rapid development of the Internet has realized high-speed information transmission and resource sharing, greatly facilitating people's lives. Embedded systems are widely used in various electr...[Details]
1. Introduction
This design was made for participating in an electronic design competition. It effectively solved the problem of the operation and control of an electric car on a seesaw. The s...[Details]
With the advent of increasingly powerful processors, image sensors, memory, and other semiconductor devices, as well as the algorithms that enable them, computer vision can be implemented in a wide...[Details]
introduction
Solar cells and LED lighting are typical applications of new energy and energy-saving and efficient technologies. Solar LED lighting uses solar cells to convert solar energy...[Details]
To differentiate their products in a crowded and competitive market, manufacturers of handheld devices often consider battery life and power management as key selling points for cell phones, PDAs, ...[Details]
July 11, 2012, Beijing - Altera Corporation (NASDAQ: ALTR) today announced the launch of 40-Gbps Ethernet (40GbE) and 100-Gbps Ethernet (100GbE) intellectual property (IP) core products. These core...[Details]
Aromatic gases are widely present in food, medicine, cosmetics and various daily chemical products, such as snacks, liquor, spices, Chinese herbal medicines, plasters, perfumes, soaps, shampoos, et...[Details]
1. Overview
The Virtual CAN Interface (VCI) function library is an application program interface specifically provided for the use of ZLGCAN devices on PCs. The functions in the library ar...[Details]
1. System Structure
This system is a simulation system of indoor air-conditioning temperature/humidity control system. The data acquisition and control center collects temperature/humidity...[Details]
1. Project Introduction
Shandong Dezhou Xingtai Paper Co., Ltd. is a newly built high-end paperboard production enterprise with domestic leading level established by Shandong Zhaodongfang Pape...[Details]
Smart lighting control systems provide high controllability for various buildings and further enhance the level of green energy. They are the core products of energy conservation and digital techn...[Details]
With the continuous consumption of earth's energy and the scarcity of resources, the harm of greenhouse effect to human beings, and the serious pollution of the atmosphere to the earth, the intern...[Details]
General LED lighting has a current limiting resistor in the driving circuit, and the power consumed by the resistor has nothing to do with the LED light emission. In order to improve efficiency, a...[Details]
With the rapid development of intelligent control technology, computers and information technology, the trend of information appliances IA (Information Application), computers and communications integ...[Details]