EEWORLDEEWORLDEEWORLD

Part Number

Search

LBHP-121135318

Description
Switch, 1X2 Port, Panel Mount, MODULE-10
CategoryWireless rf/communication    Optical fiber   
File Size292KB,3 Pages
ManufacturerLaser Components USA Inc.
Download Datasheet Parametric View All

LBHP-121135318 Overview

Switch, 1X2 Port, Panel Mount, MODULE-10

LBHP-121135318 Parametric

Parameter NameAttribute value
Objectid145065221027
Reach Compliance Codeunknown
body width26 mm
body height8.2 mm
Body length or diameter36 mm
Connection TypeDUPLEX LC CONNECTOR
Crosstalk50 dB
Fiber optic equipment typesSWITCH
Fiber type50/125, MMF
Maximum insertion loss0.8 dB
Installation featuresPANEL MOUNT
Maximum operating temperature70 °C
Minimum operating temperature-5 °C
Nominal operating wavelength1060 nm
Maximum optical input power10 mW
optical life10000000 Cycle(s)
Port configuration1X2
minimum return loss55 dB
surface mountNO
Switch actionLATCHING
switching speed3 ms
switching voltage5 V
LightBend
TM
High Power 1x1, 1x2
OptoMechanical Fiberoptic Switch
(Protected by U.S. patent 6823102 and pending patents)
Product Description
The LB series 1x1, 1x2 High Power OptoMechanical fiber optic switch can be
configured as either a 1x1 switch or a 1x2 switch. Based on Agiltron’s patent
pending, it can work in high optical power up to 10 W. The switch is driven
by a pulsed electrical signal, and the latching operation preserves the
selected optical path after the drive signal has been removed. Its integrated
status contacts to provide an electrical readout of the switch position. It is
designed for high optical power and some specific applications. Electronic
driver is available for this series of switches.
Features
Low Optical Distortions
High Isolation
High Reliability
Fail-Safe Latching
Epoxy-Free Optical Path
Performance Specification
LB Series 1x1, 1x2 HP Switch
Operation Wavelength
Insertion Loss ¹
Wavelength Dependent Loss
Polarization Dependent Loss
Return Loss ¹
Cross Talk ¹
Switching Time
Repeatability
Durability
Operating Voltage
Operating Current
(Latching/Non-Latching)
Voltage Pulse Width
(Latching)
Switching Type
Operating Temperature
Optical Power Handling
Storage Temperature
Package Dimension
Min
Typical
Max
530, 850, 980, 1060, 1310, 1550
>850nm:
0.5
0.8
530nm:
0.7
1.2
0.25
0.1
55
50
3
10
±0.02
10
7
5
5
30
20
Latching / Non Latching
-5
7
60
Unit
nm
dB
dB
dB
dB
dB
dB
ms
dB
Cycle
VDC
mA
ms
C
W
o
C
mm
o
Applications
Fault Protection
Channel Add/Drop
Channel Switching
Instrumentation
-40
36.0L x 26.0W x 8.2H
70
10
²
85
Note:
1. Exclude connectors.
2. Continuous operation, for pulse operation call.
3. Light source CPR<14dB.
LASER COMPONENTS GmbH
Werner-von-Siemens-Str. 15, 82140 Olching, Germany, Phone: +49 8142 2864 0, Fax: +49 8142 2864 11, info@lasercomponents.com
Counting the top ten energy-saving hotspots in base stations
Energy conservation and emission reduction has become one of the key tasks of operators. Recently, Zhu Jun, deputy director of the Communications Development Department of the Ministry of Industry and...
xtss Energy Infrastructure?
SHX-51 learning board, the best choice for beginners! (with pictures, manual and utility program)
Address: Room 288, Wenhui Hotel, No. 6, Wenhui Street, Haidian District, Beijing Postcode: 100082 TEL: 010-62273269 15810852141 Mr. Zhu Shunchao QQ: 744376587 Roman]E-mail[/font][font=宋体]:[/font][emai...
shx288 51mcu
It is said that the 2013 e-sports control topic (wireless control between a car and a helicopter)
[i=s]This post was last edited by paulhyde on 2014-9-15 03:04[/i] [font=微软雅黑][size=3]Repost:[/size][/font][font=微软雅黑][size=3] It is said that the car is running on the ground, and there is a helicopte...
fish001 Electronics Design Contest
Please ignore the points
Just for points...
zzxdzhw Embedded System
Let’s see how many people from BIT are in the forum?
Actually, I was asked by a friend to find someone in the Automation Department of Beijing Institute of Technology. So I just did a big search of Beijing Institute of Technology to see how many people ...
soso Talking
Ask senior experts to help
I have recently encountered a problem. The wireless communication always freezes, but the CPU runs normally, and the receiving and sending ports are normal. Dear seniors, how do you solve this problem...
xxh970820 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 121  1462  1109  1571  1861  3  30  23  32  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号