EEWORLDEEWORLDEEWORLD

Part Number

Search

54122-122101250LF

Description
Board Connector, 10 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator,
CategoryThe connector    The connector   
File Size101KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Environmental Compliance
Download Datasheet Parametric View All

54122-122101250LF Overview

Board Connector, 10 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator,

54122-122101250LF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid315326281
Reach Compliance Codecompliant
Country Of OriginFrance
ECCN codeEAR99
YTEOL9.1
body width0.19 inch
subject depth0.492 inch
body length1 inch
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU ON NI
Contact completed and terminatedMatte Tin (Sn) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Dielectric withstand voltage1500VAC V
Insulation resistance5000000000 Ω
Insulator colorBLACK
insulator materialPOLYETHYLENE
JESD-609 codee3
Manufacturer's serial number54122
Plug contact pitch0.1 inch
Match contact row spacing0.1 inch
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.54 mm
Plating thickness30u inch
Rated current (signal)3 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.12 inch
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts10
PDS: Rev :P
STATUS:Released
Printed: Apr 01, 2015
f28035 HRCAP I configured as follows, why can't I enter the interrupt?
I have read the datasheet of HRCAP of f28035 and the routine hrcap_capture_hrpwm of TI, and initialized my program according to the configuration in the routine. However, when I add the falling edge, ...
506977544 Microcontroller MCU
Painful wince memory problem, who can help me think of a solution
When I was developing with net cf, I found that after Show or ShowDialog a form, if I close or Dispose to close the window, if I open and close it again, the memory will keep decreasing and will not b...
aihys Embedded System
Master's thesis - Stewart using fuzzy neural network compensator
Stewart using fuzzy neural network compensator...
lorant RF/Wirelessly
How to connect ESP8266 to OneNet cloud platform as a safety black box for engineers
[i=s]This post was last edited by sipower on 2020-5-28 23:05[/i]The previous posts shared my preparations and system block diagrams. This time I will share something that has little to do with sensors...
sipower ST MEMS Sensor Creative Design Competition
Application of Modbus TCP to Profinet Gateway in Water Treatment System
1. There are two Siemens S7-1200PLCs and a DCS system on site. The DCS system acts as a Modbus TCP master station and provides Modbus TCP protocol type data, while the two S7-300 PLCs on site use the ...
bjnytx Integrated technical exchanges
Questions about 51 chips
Why can the MCS-51 external program memory and data memory have the same address without data conflict?...
hailong201 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 82  60  307  732  2849  2  7  15  58  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号