The EX-421 provides exceptionally low aging rates and tight temperature stabilities in an extremely small package over a wide
range of environmental conditions. This EMXO series bridges the gap between current large, high precision OCXO’s and smaller
TCXO’s. The EX-421 Series becomes the most economical choice where there is a need for spectral purity, short and long term
stability, along with small size and dramatically reduced power consumption.
Features
•
•
•
•
•
•
•
•
•
•
•
Applications
•
•
•
•
•
•
•
Mobile Data Communications
Military Portable Radio
Satellite Communications
Airborne Equipment
Avionics
Instrumentation
Marine/Land Seismic
Low Power Consumption
Precision Oscillator
Fast Warm-up
Low Phase Noise
Good Aging
Small Form Factor
SMD and Thru-Hole Mounting Option
RoHS Compliant
Standard Frequencies: 10MHz, 20MHz and 100MHz
Design/Material Sourcing/Manufacture/Test in MHS,PA COO:USA
No ITAR Restriction for importing EAR99
Previous Model Number: EX-620, EX-420 series
Performance Specifications
Frequency Stabilities
1
Parameter
vs. operating temperature range
(See temperature & stability table)
vs. aging / day (See aging table)
vs. aging / per year
vs. aging / 10 years
Initial Accuracy
vs. supply voltage change
vs. load change
Warm-up Time
-0.2
-5
-5
Min
Typ
Max
±10
±20
±30
±1.0
±100
±1
+0.2
+5
+5
45
60
Units
ppb
ppb
ppb
ppb
ppb
ppm
ppm
ppb
ppb
sec.
sec.
VDC
VDC
Watts
Watts
Watts
Condition
0… +50°C
-20… +70°C
-40… +85°C
after 30 days of operation
at time of shipment
VS ± 5%
Load ± 5%
to ± 1 ppm of final frequency (1 hour)
to ± 100 ppb of final frequency (1 hour)
Supply Voltage (Vs)
Supply voltage (Standard)
Supply voltage (Option)
Power Consumption
4.75
3.14
5.0
3.3
5.25
3.46
1.5
0.25
0.30
during warm-up
steady state @ +25°C / 3.3 Vdc
steady state @ +25°C / 5.0 Vdc
Vectron International • 267 Lowell Road, Unit 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
1 of 5
Performance Specifications
Parameter
Signal [Standard]
Load
Signal Level (Vol)
Signal Level (Voh)
Rise \ Fall Time
Rise \ Fall Time
Duty cycle
Signal [Standard]
Load
Output Power [Standard]
Output Power [Option]
Output Power [Option]
Harmonics
2.7
4.2
0
0
+3
+5
50
+4
+7
+9
-30
2.9
4.4
+Vref
Positive
45
0.8 Vs
0.8 Vs
5
3
55
Sinewave
ohm
dBm
dBm
dBm
dBc
VDC
VDC
VDC
50 Ohm load
50 Ohm load
50 Ohm load
50 Ohm load
Vs = 3.3 Vdc
Vs = 5.0 Vdc
15
0.1 Vs
Min
Typ
Max
HCMOS
Units
pF
VDC
VDC
VDC
ns
ns
%
Condition
Vs = 3.3 Vdc
Vs = 5.0 Vdc
10MHz to 29.999MHz , (10 % - 80 %)
30MHz to 100MHz , (10 % - 80 %)
Frequency Tuning (EFC)
Reference Voltage (Vref )
Tuning Voltage
Tuning Range
Tuning Slope
-90
-125
-145
-160
-165
-95
-125
-150
-160
-165
0.02
1.0
5
5.5
50
-55
-55
+85
+85
See tuning range table
Additional Parameters
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
ppb
ppb/g
grams
VDC
pF
°C
°C
1 Hz
10 Hz
100 Hz
1 KHz
10 KHz
10 Hz
100 Hz
1
KHz
10 KHz
100 KHz
Tau = 1 sec
Total Gamma
Phase Noise (10 MHz)
Phase Noise (100 MHz)
Allan Deviation (10 MHz)
Acceleration Sensitivity
Weight
Supply Voltage
Output Load
Operable temperature range
Storage temperature range
Absolute Maximum Ratings
Standard
Environmentals
Vibration
Sine
Vibration Random
Shock
Solderability
MIL-STD-202, Method 204, Condition G (30g peak, 10Hz-2000Hz)
MIL-STD-202, Method 214, Condition I-H (30g RMS
, 10Hz-2000Hz
)
MIL-STD-202, Method 213, Condition
E
(1000
g
,
0.5ms, 1/2 sine)
MIL-STD-
883
, Method 20
03
Vectron International • 267 Lowell Road, Unit 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
2 of 5
Outline Drawing / Enclosure
Surface Mounture
LABEL
LABEL
ure
Thru-hole
[11.43] MAX
.450 MAX
[13.46] MAX
.530 MAX
[13.46] MAX
.530 MAX
[11.43. MAX
.450 MAX
45°
METAL TAB AND
DOT INDICATE PIN 1
[0.64] MAX
0.025 MAX
(ALL 4 SIDES)
METAL TAB AND DOT
INDICATE PIN 1
[.64] MAX
.025 MAX
(ALL 4 SIDES)
[9.80] MAX
.385 MAX
6.60
.260
[9.40] MAX
.370 MAX
[6.60]
.260 REF
3.72±0.254
.146±.010
0.51
.020
0.46
.018
1.73
.068
2.54
.100
1
2
4
0.51
R.020
1.14
.045
(5X)
1.73
.068
2.54
.100
Pin Connections
12.70±0.254
.500±.010
Pin
1
2
EFC OPTIONS
EFC Input
Vref Output
Ground (Case)
RF Output
FIX FREQ. OPTIONS
No Connection
No Connection
Ground (Case)
RF Output
7.62
.300
1
2
4
12.70±0.254
.500±.010
8
5
8
5
4
5
8
7.62
.300
12.70±0.508
.500±.020
7.62
.300
Supply Voltage Input Supply Voltage Input
12.70±0.508
.500±.020
Standard Shipping Method
(surface mount)
Hi Janice,
We can offer MOQ of 10+pcs with
our 25+pcs pricing, under Stan-
dard USD price list. Please quote
and Jake will approve the MOQ
and price.
Thanks,John
Standard Shipping Method
(thru-hole)
3 of 5
Recommended Reflow Profiles for Pb-Free & Sn-Pb
tp
T
p
Ramp up
Ts
Critical Zone
T
L
to T
p
T
L
Temperature
t
L
Ramp dow n
Ts
min
ts
preheat
25
t 25°C to peak
Time
230°C Reflow Profile
Profile Feature
Average ramp-up rate (TL to TP)
Preheat - Temperature min Tsmin
- Temperature Min Tsmax
- Time (min to max) (ts)
Sn-Pb Assembly
3°C/seconds max.
135°C
155°C
60-90 seconds
Profile Feature
Time 25°C to Peak Temperature
Time maintained above
- Temperature (TL)
- Time (tL)
Sn-Pb Assembly
4 minutes max.
183°C
45-60 seconds
Tsmax
to TL -Ramp-up Rate
Time maintained above - Temperature (TL)
- Time (TL)
Peak Temperature (Tp)
3°C/seco
n
d
s
max.
183°C
40-60 seconds
max 230°C
Time within 5°C of actual
Peak Temperature (tp)
Ramp-down Rate
10-20 se
c
onds max.
6°C/seconds max.
Note:
All temperatures refer to topside of the package, measured on the package body surface.
260°C Reflow Profile
Profile Feature
Average ramp-up rate (TL to TP)
Pb-Free Assembly
3°C/seco
n
ds max.
Profile Feature
Time 25°C to Peak Temperature
Pb-Free Assembly
8 minutes max.
Preheat - Temperature min Tsmin
- Temperature min Tsmax
- Time (min to max) (ts)
Tsmax
to TL -Ramp-up Rate
Time maintained above - Temperature (TL)
- Time (TL)
Peak Temperature (Tp)
150°C
200°C
60-180 seconds
3°C/seco
n
d
s
max.
217°C
60-150 seconds
max 260°C
Time maintained above
- Temperature (TL)
- Time (tL)
Time within 5°C of actual
Peak Temperature (tp)
Ramp-down Rate
6°C/second
s
max.
217°C
60-150 seconds
20-40 se
c
onds max.
Note:
All temperatures refer to topside of the package, measured on the package body surface.
Vectron International • 267 Lowell Road, Unit 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
4 of 5
Ordering Information
EX - 421 0 - D A P - 108 0 - 10M0000000
Product Family
EX: EMXO
Package
13x 13mm
Configuration
0: Surface Mount
1:
Thru-hole
Stability Code
108: ±10ppb
208: ±20ppb
308: ±30ppb
508: ±50ppb
758: ±75ppb
107: ±100ppb
Frequency
XXMXXXX XXX
Frequency Control
0: Fixed Frequency (HCMOS)
1: Fixed Frequency (0 dBm)
2: Fixed Frequency (+3 dBm)
3: Electrical Tuning (HCMOS)
4: Electrical Tuning (0 dBm)
5: Electrical Tuning (+3 dBm)
6: Fixed Frequency (+5 dBm)
7: Electrical Tuning (+5 dBm)
Supply
Voltage
D: 5 Vdc
E: 3.3 Vdc
RF Output Code
(
S
ee Note 2)
(
S
ee Note 2)
(
S
ee Note 2)
(
S
ee Note 2)
A: HCMOS
E: Sinewave
Temperature Range
A: -55°C to +85°C
E: -40°C to +85°C
J: -20°C to +70°C
P: 0°C to +50°C
Temperature Range and Stability Table
( Temperature Stability Reference to (F
max
-F
min
)/2 )
Stability/Temperature
A: -55°C to +85°C E: -40°C to +85°C J: -20°C to +70°C P: 0°C to +50°C
108 (+/-10ppb)
208 (+/-20ppb)
308 (+/-30ppb)
508 (+/-50ppb)
758 (+/-75ppb)
107 (+/-100ppb)
10-20MHz
10-50MHz
10-80MHz
10-100MHz
10-20MHz
10-50MHz
10-100MHz
10
-100MHz
10-20MHz
10-20MHz
10-20MHz
10-50MHz
10-100MHz
10-100MHz
10-20MHz
10-20MHz
10-50MHz
10-100MHz
10-100MHz
Aging Table
Frequency Range
10MHz to 15MHz
>15MHz to 50MHz
>50MHz
to 100MHz
Daily Rate Yearly Rate
(ppb/day) (ppb/year)
±1
±2
±2
± 100
± 200
± 200
Tuning Range
(ppm)
±1
±2
Not Available
Notes:
1.
Contact factory for improved stabilities or additional product options. Not all options and codes are available at all
frequencies.
2. Electrical Tuning Option available up to 50MHz. Only fixed Frequency Option beyond 50MHz output frequency.
(+/-10ppb)
Unless otherwise stated, all values are valid after warm-up time and refer to typical conditions for supply voltage,
10-30MHz
3
.
208 (+/-20ppb)
frequency control voltage, load,
and
temperature (25°C).
10-30MHz
10-30MHz
308 (+/-30ppb)
Phase noise degrades with increasing output frequency.
4
.
5
. Subject to technical modification.
6
.
Contact factory for availability.
For Additional Information, Please Contact
Vectron International
267 Lowell Road, Unit 102
Hudson, NH 03051
Tel: 1.888.328.7661
Fax: 1.888.329.8328
USA:
Vectron International
Landstrasse, D-74924
Neckarbischofsheim, Germany
Tel: +49 (0) 3328.4784.17
Fax: +49 (0) 3328.4784.30
Europe:
Vectron International
68 Yin Cheng Road(C), 22nd Floor
One LuJiaZui
Pudog, Shanghai 200120, China
Tel: 86.21.6194.6886
Fax: 86.21.6194.6699
Asia:
Disclaimer
Vectron International reserves the right to make changes to the product(s) and or information contained herein without notice. No liability is assumed as a result of their use or application.
No rights under any patent accompany the sale of any such product(s) or information.
Vectron International • 267 Lowell Road, Unit 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
I've been making a small car recently, using L298 as an H-bridge. The battery is a 9v battery used for digital multimeters. Two are connected in series, and after passing through 7812, 12V is output t...
Abstract: In order to apply JPEG2000 to portable products, a hardware implementation scheme with efficient storage structure is adopted, and the corresponding register group and control logic are desi...
Who says the bankruptcies are just a wind in the sky? We are facing the same problem!!! Our main products are thermostats and industrial control systems, with a gross profit of only a few points. Now,...
Dynamic scanning drives 7 segments of 1.5-inch common cathode digital tubes (each segment has 2 cores connected in series), totaling 4 digits.Each segment is 10ma*7 segments = 70ma. The common end of ...
This time, I learned about SmartConfig and Airkiss one-click network configuration, and connected ESP8266 to the cloud with one click.
Generally, if a WiFi module wants to connect to the Internet, the...
With the rapid development of science and technology, especially the widespread application of digital technology and various ultra-large-scale integrated circuits, electronic equipment, especially...[Details]
Sailing is gaining more and more attention. How to use modern technology to assist training and improve competition results is particularly important. Considering the real-time data collection in t...[Details]
introduction
my country has a vast territory and a large population. The scale of housing construction is huge, and the amount of residential construction is large and wide. It is still on t...[Details]
1 Introduction
With the acceleration of the pace of urban modernization, society has higher requirements for urban road lighting and urban lighting projects. The state has clearly required tha...[Details]
Introduction
Power subsystems are becoming more and more integrated into the overall system. Power systems have moved from being separate "essential dangerous devices" to being monitorable...[Details]
From the PIC16F946 datasheet, we know that there are two ways to write values to the LCD for display:
1. Directly write the value to LCDDATA1~LCDDATA23
2. Use disconnect t...[Details]
1. What is temperature?
Heat is a type of molecular motion. The hotter an object is, the faster its molecules move. Absolute zero is defined as the temperature at which all molecular motion ...[Details]
This week, Microsoft held its 2012 Microsoft Worldwide Partner Conference (WPC) in Toronto, Canada. At the conference, Microsoft showed its new products and services to partners around the world. A...[Details]
1 Introduction
There have been many studies on the detection and protection of power grid short circuit and line fault. The short circuit, overload and overvoltage protectors on the market have ...[Details]
Single-chip microcomputers are widely used because of their small size, powerful functions and low price. This article introduces the method of designing a micro electronic piano using the AT89C51 sin...[Details]
introduction
MAX6636 is a multi-channel precision temperature monitor that can not only monitor local temperature, but also connect up to 6 diodes externally. Each channel has a programmable...[Details]
1. Disadvantages of choosing too high a voltage level
Choosing too high a voltage level will result in too high an investment and a long payback period. As the voltage level increases, the...[Details]
0 Introduction
High-precision current source can provide high-precision current supply for precision instruments, and is suitable for automatic measurement tasks of various resistors in semico...[Details]
At present, a large number of cooling tower fans, speed fans and special fans are in use in petroleum, chemical, pharmaceutical, metallurgical and other enterprises. Some fans have no monitoring in...[Details]
With the rapid development of wireless
digital communication
, more challenges have been raised for integrated circuit design and testing. In the product design stage, in order to ensure
t...[Details]