Y3 - CERTIFIED SAFETY CAPACITORS
NOVACAP offers a line of MLC chip capacitors, sizes LS 1808, LS 1812, X
2
, Y
3
Class
Compliant* specifically designed for use in modem, facsimile, telephone and other elec-
tronic equipment where lightning or overvoltage surges can occur. These parts are
rated at 250 Vac safety approved and certified to EN 60950. The product is compliant
to Standards EN 132400: 1994/A2: 1998/IEC60384-14, Second Edition: 1993/A1:1995,
and meet the requirements of EN61000-4-5, IEC1000-4-5, and IEC801-4-5. Capacitors
are available in COG (NP0) and X7R dielectrics.
SIZE
LENGTH L
WIDTH W
T MAX
MB
CREEPAGE
LS 1808
(Y³)
.180 (4.57)
.080 (2.03)
See Chart
LS 1812
(Y³)
.180 (4.57)
.125 (3.18)
See Chart
W
MB
Cap (EIA)
5R0
6R8
8R2
100
L
T
LS 1808
COG/NPO
LS 1808
X7R
LS 1812
COG/NPO
120
150
180
220
270
330
390
470
560
680
820
.024 (.609) Typical .024 (.609) Typical
.102 (2.60) Min
.102 (2.60) Min
Dimensions are in inches, bracketed dimensions in millimeters.
Tolerances for length and width are .015” (0.38 mm).
TUV
STANDARDS
(LS 1808N) R9972698.01,.02,.03 (LS1808B) R2272835.01,.02
(LS1812N) R9972698.05
STANDARDS
EN 132400, EN 60950, IEC 60384-14 Second Edition, Class X Y .
NWGQ2.E208336 and NWGQ8.E208336
2
3
101
121
151
181
221
UL
Maximum Thickness of .065”.
No “X065” required in the part number. ie: LS1808N151K302NT
271
331
391
471
561
681
821
102
122
152
182
222
Maximum Thickness of .080”.
“X080” required in the part number. ie: LS1808N102K302NX080T
Maximum Thickness of .100”.
“X100” required in the part number. ie: LS1812N202K302NX100T
HOW TO ORDER
LS1808
SIZE
LS 1808
LS 1812
N
N = COG
B = X7R
102
Value in Picofarads
Two significant fig-
ures, followed by
number of zeros:
102 = 1000 pF
K
TOLERANCE
J = +/- 5 %
K = +/- 10 %
M = +/- 20 %
302
Two significant
figures, followed
by number of
zeros:
302 = 3000 VDC
N
(100% Tin)
X080
Not required for
.065”Max Thickness,
X080 or X100
required for
thickness >.065”
See Chart
T
PACKING
OPTION
T=Reeled
M
MARKING
OPTION
M = Marked
(See Marking
Specification)
DIELECTRIC CAPACITANCE
VOLTAGE-SURGE TERMINATION
THICKNESS
N = Nickel Barrier
OPTION
38
*Compliant with Robustness of Termination (cl 4.3) test according to IEC 60384-1 amendment 3 cl 4.34 and 4.35 Resistance to
Soldering Heat (cl 4.4) tested according to IEC 60384-1 amendment 3 cl. 4.14.2, Impulse Test made with 2.5 KV or 5.0KV as required
according to 6.4.2.1 in EN 60950. The creepage distance between live parts of different polarity meets the requirements of IEC 60950.
.
www.
N O V A C A P
.
com
38