Part Number

Search

DRR-DTH 55-65

Description
magnetic / reed switches
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size106KB,1 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Environmental Compliance
Download Datasheet Parametric View All

DRR-DTH 55-65 Overview

magnetic / reed switches

DRR-DTH 55-65 Parametric

Parameter NameAttribute value
ManufactureLittelfuse
Product CategoryMagnetic / Reed Switches
RoHSYes
Switch TypeHermetically Sealed Switch
Contact Form1 Form C (SPDT)
Contact Rating50 W
Operate Range55 At to 65 A
Termination StyleAxial
PackagingCase
Contact PositiNormally Closed, Change Ove
Factory Pack Quantity100
Voltage Rating AC500 V
www.hamlin.com
DRR-DTH/DRT
-DTH Features and Benefits
Features
Changeover switch with
39.67mm x 5.53mm (1.562” x
0.21”) glass envelope
Capable of carrying up to 3 Amps
Maximum contact rating up to
50 Watts
Minimum voltage breakdown
1200 Vdc
10
9
Ohms insulation resistance
Available sensitivity range
50-80 AT
Benefits
Hermetically sealed switch contacts
are not effected by and have no effect
on their external environment
Can be used as changeover or
normally closed contact
Capable of switching European
mains voltage
Low, stable contact resistance
Zero operating power required for
contact closure
Fit and forget durability
Applications
Security
Limit switching
Industrial safety applications
White goods applications
Automotive applications
DIMENSIONS (in) mm
Switch Type
Contact Form
ELECTRICAL RATINGS
Contact Rating (2)
Voltage
Current
Resistance
Capacitance
Temperature
Switching
Breakdown
Switching
Carry
Contact, Initial
Insulation
Contact
Operating
Storage (6)
Watt - max.
Vdc - max.
Vdc - min.
A - max.
A - max.
- max.
- min.
pF - typ.
°C
°C
DRR-DTH
C
DRT
-DTH
*
C
* NOT RECOMMENDED
FOR LIGHT LOADS
30
500
1200
0.5
3.0
0.125
10
9
2.0
-20 to +125
-65 to +125
50
500
1000
1.5
2.0
0.500 (7)
10
9
2.0
-20 to +125
-65 to +125
OPERATING CHARACTERISTICS
Operate Time (3)
Release Time (3)
Shock
Vibration
Resonant Frequency
MAGNETIC CHARACTERISTICS
Pull-In Range (4)
Rating Sensitivity (5)
Test Coil
Ampere Turns
Ampere Turns
50-80
60
L4988
50-80
60
L4988
11ms ⁄
2
sine wave
50-2000 Hertz
1
ms - max.
ms - max.
G - max.
G - max.
Hz - typ.
4.5
7.0
10
15
2750
5.5
8.0
10
15
2750
Notes
1)
2)
3)
For details on electrical specifications, contact Hamlin.
Contact rating-Product of the switching voltage and current should never exceed the
wattage rating.
Contact Hamlin for additional load/life information.
Operate/Release Time-per EIA/NARM RS421A, diode suppressed coil.
4) Pull in Range-Contact Hamlin for tolerances available within this range.
5) Rating Sensitivity-The value at which contact ratings and operating characteristics are
determined. Derating may be required below this value.
6) Storage Temperature-Long time exposure at elevated temperature may degrade
solderability of the leads.
7) Contact resistance measured at 36 Vdc, 100 ma, switched wet.
USA
UK
Germany
France
Tel:
Tel:
Tel:
Tel:
+1 920 648 3000
Fax: +1 920 648 3001
Email: sales.us@hamlin.com
+44 (0)1379 649700
Fax: +44 (0)1379 649702
Email: sales.uk@hamlin.com
+49 (0) 6142 923920
Fax: +49 (0) 6142 923921
Email: sales.de@hamlin.com
+33 (0) 1 6047 3000
Fax: +33 (0) 1 6015 9136
Email: sales.fr@hamlin.com
ISSUE No: 3 DATE: 28/09/0
INFORMATION PROVIDED ON THIS DATA SHEET IS PROVIDED FOR INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY
PARTICULAR PURPOSE. Product performance may be affected by the application to which the product is applied. Upon request, HAMLIN will assist purchasers by providing information
specific to any particular application. HAMLIN disclaims any and all liability whatsoever for any purchaser’s reliance upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
Synchronous flyback circuit for efficient conversion
When designing a non-isolated step-down regulator, a buck regulator is usually the first choice unless the ratio of VIN to VOUT is greater than 10 , the input voltage is very high, or both. Low duty f...
feifei Analog electronics
Code protection feature of TI MSP430
MSP microcontrollers (MCUs) have several features that help control code accessibility within the device and add different layers of code access management and protection strategies. These features in...
火辣西米秀 Microcontroller MCU
Circuit Diagram Recognition 5-How to Recognize Complex Circuit Diagrams
[align=left][color=rgb(34, 34, 34)][font="]When looking at complex circuit diagrams, we should follow the ideas and methods from the local to the whole, from input to output, breaking the whole into p...
tiankai001 Integrated technical exchanges
Detailed explanation of STM32 startup file
This article explains the code of the STM32 startup file startup_stm32f10x_hd.s, which can be found in any STM32F10x project. You can click the end of the article to read the original text and downloa...
可乐zzZ stm32/stm8
A Engineer's Guide to Instrumentation Amplifiers
The file is too large to upload. Here is a brief introduction to instrumentation amplifier devices: http://www.analog.com/UploadedFiles/Associated_Docs/10568595IN_AMP_GUIDE_Chinese_Rev1.pdf...
soso Analog electronics
A way to control the output level of printed information
[i=s]This post was last edited by jorya_txj on 2016-7-11 10:19[/i] During the debugging process, observing the print information output by the system is an indispensable means of debugging, and it is ...
jorya_txj Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2555  746  973  2779  345  52  16  20  56  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号