EEWORLDEEWORLDEEWORLD

Part Number

Search

PH42M25-210GABCPR6/11/4.2-L

Description
Board Connector, 20 Contact(s), 2 Row(s), Male, Straight, 0.165 inch Pitch, Surface Mount Terminal, Black Insulator, Receptacle
CategoryThe connector    The connector   
File Size197KB,1 Pages
ManufacturerAmtek Technology Co., Ltd.
Environmental Compliance
Download Datasheet Parametric View All

PH42M25-210GABCPR6/11/4.2-L Overview

Board Connector, 20 Contact(s), 2 Row(s), Male, Straight, 0.165 inch Pitch, Surface Mount Terminal, Black Insulator, Receptacle

PH42M25-210GABCPR6/11/4.2-L Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid305329629
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresROHS COMPLIANT
Board mount optionsPEG
body width0.378 inch
subject depth0.098 inch
body length1.673 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU
Contact completed and terminatedGold (Au)
Contact point genderMALE
Contact materialCOPPER ALLOY
contact modeRECTANGULAR
Contact resistance20 mΩ
Contact styleSQ PIN-SKT
Dielectric withstand voltage1000VAC V
Insulation resistance1000000000 Ω
Insulator colorBLACK
insulator materialPOLYBUTYLENE TEREPHTHALATE
JESD-609 codee4
Manufacturer's serial numberPH42
Plug contact pitch0.165 inch
Match contact row spacing0.165 inch
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
PCB contact patternRECTANGULAR
PCB contact row spacing7.0104 mm
Plating thickness5u inch
Rated current (signal)7 A
GuidelineUL
reliabilityCOMMERCIAL
Terminal pitch4.191 mm
Termination typeSURFACE MOUNT
Total number of contacts20

PH42M25-210GABCPR6/11/4.2-L Preview

P
in Header 4.2mm
Pin Header 4.2mm 2 Row H=2.5mm SMT Type
Specifications
Current Rate:7 AMP
Insulation Resistance:1000MΩ Min.
Contact Resistance:20mΩ Max.
Dielectric Voltage:1000V AC for one minute
Operation Temperature:-40°C to +105°C
Materila
Insulator:Polyester,UL 94V-0
Standard SMT:Nylon 6T,
Straight:Nylon 66
Termial:Copper Alloy
Plating:Tin Plated
Part No.:PH42M25-2XX-U
Pin Header 4.2mm 2 Row H=2.5mm Straight Type
Part No.:PH42S25-2XX-L
A/B
A/B/C
Fill in Dimensions For
Special Design
A/B For PH42S
A/B/C For PH42M
P H 4 2 X 2 5
-
2 X X
X
B
X
X
X
-
X
M:SMT Type
S:Straight Type
No. of Contacts Per Row
(02~16)
G:Gold Flash
GA:Gold 5u"
GB:Gold 10u"
GC:Gold 20u"
GD:Gold 30u"
T:Tin Plated
S:Selective
SA:Selective 5u"
SB:Selective 10u"
SC:Selective 20u"
SD:Selective 30u"
TE:Tin 200u"
O:W/O Cap
O:W/O Peg
B:Bag Package
T:Tube
R:Tape & Reel
(For SMT Only)
L:RoHS + PBT
U:RoHS + Nylon 6T
(U For SMT Only)
C:With Cap
(For SMT Only)
P:With Peg
(For SMT Only)
B:Black Insulator
Standard Recommended
www.amtek-co.com.tw
2-142
The problem of being unable to sample data when using the 28335 ADC module to sample current
1. Debugging description:Use the ADC module of DSP238335 to sample current, use the EPWM module to trigger ADC sampling, ADC sampling cascade mode, and EPWM uses up-down mode.To realize the function, ...
Jacktang Microcontroller MCU
I need help on CE, the program is slow and has a very special problem
Using RS232, TCP/IP to transfer files between PC and PDA. Now a very strange problem is that the program runs normally on Mobile and CE, and it is normal without clicking to transfer. When the file is...
flystonenj Embedded System
FPGA_100 Days of Journey_Vending Machine
...
至芯科技FPGA大牛 FPGA/CPLD
About Allegro copper plating
Is this how the guys who use Allegro lay out the copper skin? Lay a whole piece of copper sheet and buckle it to doubt life...
summer2019 PCB Design
Understanding Logic Analyzers
[url=http://article.ednchina.com/word/147555.aspx]Logic analyzer[/url] is an instrument that uses a clock to collect and display digital signals from test equipment. Its main function is to determine ...
黑衣人 Test/Measurement
I have an idea and I want to find someone to collaborate on the design
Because I am not an electronic engineering major, I just have an idea in my head, but I don’t know how to realize it. I will now give a brief introduction to my product. I hope that those masters who ...
入微的保护 Suggestions & Announcements

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 230  16  181  522  1439  5  1  4  11  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号