EEWORLDEEWORLDEEWORLD

Part Number

Search

333-084-560-203

Description
Card Edge Connector, 84 Contact(s), 2 Row(s), Female, Right Angle, 0.156 inch Pitch, Surface Mount Terminal, Hole 0.116, Green Insulator,
CategoryThe connector    The connector   
File Size288KB,3 Pages
ManufacturerEDAC
Environmental Compliance
Download Datasheet Parametric View All

333-084-560-203 Online Shopping

Suppliers Part Number Price MOQ In stock  
333-084-560-203 - - View Buy Now

333-084-560-203 Overview

Card Edge Connector, 84 Contact(s), 2 Row(s), Female, Right Angle, 0.156 inch Pitch, Surface Mount Terminal, Hole 0.116, Green Insulator,

333-084-560-203 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145236762144
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL6
body width0.37 inch
subject depth0.6 inch
body length7.4 inch
Connector typeCARD EDGE CONNECTOR
Contact point genderFEMALE
contact modeRECTANGULAR
Contact resistance10 mΩ
Contact styleBELLOWED TYPE
Dielectric withstand voltage2500VAC V
Filter functionNO
maximum insertion force4.45 N
Insulation resistance5000000000 Ω
Insulator colorGREEN
insulator materialPOLYETHYLENE/POLYESTER
Plug contact pitch0.156 inch
Mixed contactsNO
Installation option 1HOLE 0.116
Installation option 2LOCKING
Installation methodRIGHT ANGLE
Installation typeBOARD
PCB row number2
Number of rows loaded2
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
OptionsGENERAL PURPOSE
PCB contact patternRECTANGULAR
Rated current (signal)3 A
GuidelineUL
Terminal length0.375 inch
Terminal pitch3.96 mm
Termination typeSURFACE MOUNT
Total number of contacts84
UL Flammability Code94V-0
Evacuation force-minimum value0.28 N

333-084-560-203 Preview

333
SERIES
Card Edge Connectors 0.156” (3.96mm) Pitch
Features:
0.156” (3.96mm) contact spacing x 0.200” (5.08mm) row spacing
Accepts 0.062” (1.57mm) nominal thickness P.C. board
High profile insulator body, 0.600” (15.24mm)
Card slot depth of 0.388” (9.86mm)
Contact termination options include P.C. tail, wire hole, wire wrap, 90 degree and extender board bends
Single or dual row configurations
Large variety of mounting options, flush or offset lugs
Accepts between contact and in-contact polarizing keys
RoHS Compliant
Specifications:
Insulator Material
Contact Material
Contact Plating
Current Rating
Contact Resistance
Dielectric Withstanding Voltage
Insulation Resistance
Operating Temperature
Insertion Force
Withdrawal Force
UL 94V-0 Thermoplastic Polyester, Green Color
Copper Alloy
Gold Plating on mating area and Tin Plating on tails with Nickel underplating all over
3 amps
10 milliohms maximum
1800 V AC rms at sea level between adjacent contacts
5000 megaohms minimum
-40°C to +105°C
16 oz (4.45 N) maximum per contact pair when tested with .070” (1.78mm) thick gauge
1 oz (0.28 N) minimum per contact pair when tested with .054” (1.37mm) thick gauge
Example Part Number:
Series
Total Number of Contacts
Contact Code
333-044-520-204
Contact Rows and Insulator Style
Mounting Options
Series:
333
Total Number of Contacts:
006, 007, . . . . 043
012, 014, . . . . 086
Contact Rows:
1
2
6
8
Mounting Options:
01
02
03
04
07
08
12
Contact Rows:
Single Row
Dual Row
Description:
Single Row
Dual Row
Single Row
Dual Row
Description:
No Mounting Lug
Ø.128” (Ø3.25mm) Mounting Holes
Ø.116” (Ø2.95mm) I.D. Floating Eyelets
Ø.156” (Ø3.96mm) Mounting Holes
M3-0.5 Metric Threaded Inserts
#4-40 Unified Threaded Inserts
Ø.128” (Ø3.25mm) Side Mounting Holes
Insulator Style:
Flush Mounting Lugs
Flush Mounting Lugs
.170 (4.32) Offset Lugs
.170 (4.32) Offset Lugs
Contact Code
500
520
521
523
524
540
541
542
544
555
556
558
559
560
Tail Description
Wire Hole
P.C. Tail
P.C. Tail
P.C. Tail
P.C. Tail
Wire Wrap
Wire Wrap
Wire Wrap
Wire Wrap
EXTENDER BOARD BEND
EXTENDER BOARD BEND
90 DEGREE BEND
90 DEGREE BEND
EXTENDER BOARD BEND
Tail Size
.050 x .025 (1.27 x 0.64)
.030 x .018 (0.76 x 0.46)
.025 Square (0.64 Square)
.025 Square (0.64 Square)
.018 Square (0.46 Square)
.025 Square (0.64 Square)
.025 Square (0.64 Square)
.025 Square (0.64 Square)
.050 x .025 (1.27 x 0.64)
(Code 500 Contacts)
(Code 520 Contacts)
(Code 541 Contacts)
(Code 541 Contacts)
(Code 523 Contacts)
Tail Length “G”
.260 (6.60)
.175 (4.45)
.150 (3.81)
.390 (9.91)
.175 (4.45)
.560 (14.22)
.750 (19.05)
.645 (16.38)
.750 (19.05)
Ordering Code Notes:
1) All connector sizes up to 43 contacts single row / 86 contacts dual row
are available upon request.
2) When the 500 contact code is ordered, Green Diallyl Phthalate
insulator material will be supplied.
3) For details of the extender board and 90 degree bends refer to next page.
4 For lugless connectors, code 01 mounting, specify contact row code 1 or 2.
5) For details of the mounting options refer to next pages.
www.edac.net
customerservice@edac.net
333
SERIES
Card Edge Connectors 0.156” (3.96mm) Pitch
NUMBER OF CONTACTS
Single
6
10
15
18
22
28
36
37
43
Double
12
20
30
36
44
56
72
74
86
Inch
1.784
2.408
3.148
3.656
4.280
5.216
6.464
6.620
7.556
"A"
mm
45.31
61.16
79.96
92.86
108.71
132.49
164.19
168.15
191.92
Inch
1.534
2.158
2.898
3.406
4.030
4.966
6.214
6.370
7.306
"B"
mm
38.96
54.81
73.61
86.51
102.36
126.14
157.84
161.80
185.57
Inch
1.261
1.885
2.625
3.133
3.757
4.693
5.941
6.097
7.033
"C"
mm
32.03
47.88
66.68
79.58
95.43
119.20
150.90
154.86
178.64
Inch
1.100
1.724
2.464
2.972
3.596
4.532
5.780
5.936
6.872
"D"
mm
27.94
43.79
62.59
75.49
91.34
115.11
146.81
150.77
174.55
Inch
0.780
1.404
2.144
2.652
3.276
4.212
5.460
5.616
6.552
"E"
mm
19.81
35.66
54.46
67.36
83.21
106.98
138.68
142.65
166.42
www.edac.net
customerservice@edac.net
333
SERIES
Card Edge Connectors 0.156” (3.96mm) Pitch
Mounting Options:
0.12 [2.95] I.D.
Floating Eyelets
0.25 [6.35] Dia.
.144 (3.66) Dia.
Through Hole
0.010 [0.25]
Radial Float
Code x01
Code x02
Code x03
0.01 [0.13]
Vertical Float
0.33 [8.33]
0.11 [2.79]
.156 (3.96) Dia.
Through Hole
M5-0.5 Metric
Insert
#4-40 UNC
Threaded Insert
1.71 [43.48]
0.25 [6.35]
Code x04
www.edac.net
Code x07
Code x08
Code x78
customerservice@edac.net
Does anyone have experience in implementing the PPP protocol on the μC/OS-II operating system? Could you please give me some guidance? I would greatly appreciate it!
Does anyone have experience in implementing PPP protocol on μC/OS-II operating system? Can you give me some guidance? I will reward you handsomely! It's really urgent. Please help me. I will be gratef...
liyanping Embedded System
"Practice together in 2021" + continue to persevere
2020 is an extraordinary year, with both gains and losses 2020 is a confusing year. I have been thinking about where my future will go. I have experienced pain and depression. 2020 was a dull year. I ...
清欢渡 Talking
[TI recommended course] #[High Precision Laboratory] Magnetic Sensor Technology#
//training.eeworld.com.cn/TI/show/course/5475...
EricCheng TI Technology Forum
The Loser of Qixi Festival
[i=s] This post was last edited by elvike on 2014-8-2 02:23 [/i] Because of house hunting, moving, and internet disconnection, I wasted a lot of time. I finally got online yesterday, so I came back to...
elvike DSP and ARM Processors
I accidentally saw a router that is only as big as a mahjong tile. Would you consider using it?
[color=#333333][backcolor=rgb(255, 255, 255)][font=arial, 宋体, sans-serif][size=14px]Mahjong Router H570A is a portable router. It can realize plug-and-play mobile office anytime and anywhere. It can f...
youluo Creative Market
Questions about Screen Saver
下面是自带的WinCE500自带的帮助文件:ms-help://MS.WindowsCE.500/wcetarget5/html/wce50conConfigureScreenSaversInThinClient.htmIf you want the shell to load a screen saver after a specified period of time, you must in...
123456ds Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 344  925  229  1772  383  7  19  5  36  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号