Wiring-reduction Units
that allow several switching
signals to be transmitted
over just 2 wires
B7A
Link Terminals
Table of Contents
j
I/O Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
"
I/O Combination Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
"
10-point Terminal Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
"
CQM1 B7A Interface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
"
CS1 and C200HX/C200HG/C200HE/C200HS/C200H B7A Interface Units
j
Connection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . .
"
Connection with CQM1H/CQM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
"
Connection with CS1/
SYSMAC C200HX/C200HG/C200HE/C200H/C200HS . . . . . . . . . . . . . . .
"
Connection with CVM1/CV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
j
Line of Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
"
B7AS
Link Terminals with 32 Inputs
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Link Terminals with 16 I/O Points (Screw Terminal and Modular
Models)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Link Terminals with PLC Connectors (16 and 32 I/O Points)
Link Terminals with 16 Relay Outputs
. . . . . . . . . . . . . . . . . . . . . . .
Link Terminal with 16 Inputs and 16 Outputs
. . . . . . . . . . . . . . . .
Link Terminals with 8 Inputs and 8 Outputs
. . . . . . . . . . . . . . . . .
Hybrid IC Link Terminals
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Link Terminals with Sensor I/O Connectors
. . . . . . . . . . . . . . . . .
B7AC Interface Terminal (10 Inputs
3)
. . . . . . . . . . . . . . . . . . . .
"
B7A/B7AS
"
B7A
"
G70D-B7A
"
B7AM-6BS
"
B7AM-8
"
B7AH
"
B7AC
"
DRT1-B7AC
"
B7A
Link Terminals with 10 I/O Points
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
B7A Interface Units for CQM1/CQM1H PLCs
. . . . . . . . . . . . . . .
B7A Interface Units for CS1/C200HS/HX/HG/HE PLCs
. . . . .
Power Couplers
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
"
CQM1-B7A
"
C200H-B7A
"
B7AP
Product List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Link Terminals
B7A
Five Types and 55 Models Can Be Combined Freely for a Variety of Applications to
Save Wiring Effort
Ordering Information
I/O Combinations
32-point models (screw terminal models), 16-point models (screw terminal models, modular models, and hybrid IC models), PLC connector
models (16-point models and 32-point models), I/O combination models (16-input/16-output models and 8-input/8-output models), 10-point
models (screw terminal models, modular models, and sensor I/O connector models), and Interface Units for PLCs (CQM1 and C200H/HS) are
available for a variety of applications.
32-point, 16-point, and PLC Connector Models
Output (reception)
Screw
terminal
models
(16 points)
B7A, B7AS
Screw
terminal
models with
relay outputs
(16 points)
G70D-R6-B7A
Modular
models
(16 points)
Hybrid IC
models
(16 points)
PLC
connector
models
(16 points)
B7A
PLC
connector
models
(32 points)
B7A
Input (transmission)
Screw
terminal
models
(32 points)
Screw
terminal
models
(16 points)
Modular
models
(16 points)
Hybrid IC
models
(16 points)
PLC
connector
models
(16 points)
PLC
connector
models
(32 points)
Note:
B7AS
B7A
B7AH
A
B7A, B7AS
A
A
A
A
B
B7A
B7AH
B
B
B
B
B
A
B7A
B7A
A
A
A
A
A
B
Only normal I/O delay time (typically 19.2 ms) is available.
Meaning of “A” and “B”
A: Combinations with one 32-point model connected to two 16-point models.
16 points
32 points
16 points
B: One-to-one combinations of models with the same number of input or output points.
32 points
Note:
32 points
16 points
16 points
With 32-point models, 16-point models, and PLC connector models, two I/O delay time settings are available: high-speed (typically
3 ms) and normal (typically 19.2 ms). Use the same settings for combined Terminals.
1
B7A
I/O Combination Models
Input (Transmission)
Screw terminal model (16 points)
I/O combination screw terminal model
(16 inputs, 16 outputs)
B7A
Output (Reception)
Screw terminal model (16 points)
B7A
B7AS
Output
B7AM
Input
B7A
B7AS
Modular model (16 points)
Set the I/O delay time setting switch to
the setting of B7A Terminals used in
combination.
Screw terminal model with
relay outputs (16 points)
PLC connector model (16 points)
Hybrid IC model (16 points)
Note:
Only normal I/O delay
time (typically 19.2 ms)
is available.
Modular model (16 points)
PLC connector model (32 points)
Note:
Two B7AM
Terminals
are
required for
32 inputs.
PLC connector model (16 points)
Hybrid IC model (16 points)
PLC connector model (32 points)
Note:
Two B7AM
Terminals
are
required for
32 outputs.
Screw terminal model
(16 input and 16 output points)
B7AM
Input
Output
Screw terminal model
(16 input and 16 output points)
B7AM
Output
Input
Screw terminal model
(8 input and 8 output points)
B7AM
Input
Output
Screw terminal model
(8 input and 8 output points)
B7AM
Output
Input
2
B7A
10-point Terminal Models
Input (Transmission)
Screw terminal model (10 points)
B7A
B7A
B7A
Output (Reception)
Screw terminal model (10 points)
Modular model (10 points)
B7A
B7A
Modular model (10 points)
FA connector model (10 points)
B7AC
DeviceNet model
DRT1-B7AC
Note:
The 10-point model has a normal I/O delay time of 19.2 m (typical); 10-point models with short I/O delay time are not available.
The transmission signals of the 16-point PLC connector model are not compatible with those of the 10-point model. Therefore
16-point PLC connector models and 10-point models cannot be used in combination.
3