60W Single Output LED Power Supply
■
Features :
CEN-60
series
‧
Universal AC input / Full range (up to 295VAC)
‧
Protections: Short circuit /
Over current
/ Over voltage / Over temperature
‧
Output voltage and constant current level adjustable
‧
Built-in active PFC function
‧
IP66 design for indoor or outdoor installations
‧
Class 2 power unit
‧
Cooling by free air convection
‧
100% full load burn-in test
‧
High reliability
‧
Suitable for LED lighting and moving sign applications
‧
Compliance to worldwide safety regulations for lighting
‧
Suitable for dry / damp / wet locations
‧
3 years warranty
F
110
M
M
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
CEN-60-12
12V
5A
0 ~ 5A
60W
CONSTANT CURRENT REGION
Note.5
9 ~ 12V
CEN-60-15
15V
11.25 ~ 15V
4A
0 ~ 4A
60W
2.4Vp-p
3 ~ 4A
CEN-60-20
20V
15 ~ 20V
3A
0 ~ 3A
60W
1.8Vp-p
17 ~ 22V
2.3 ~ 3A
SELV
IP66
CEN-60-30
30V
22.5 ~ 30V
2A
0 ~ 2A
60W
3Vp-p
27 ~ 33V
1.5 ~ 2A
CEN-60-36
36V
27 ~ 36V
1.7A
0 ~ 1.7A
61.2W
3.6Vp-p
33 ~ 40V
1.3 ~ 1.7A
..
CEN-60-24
24V
18 ~ 24V
2.5A
0 ~ 2.5A
60W
2.4Vp-p
22 ~ 27V
1.9 ~ 2.5A
CEN-60-42
42V
31.5 ~ 42V
1.45A
0 ~ 1.45A
60.9W
4Vp-p
37 ~ 46V
1.1 ~ 1.45A
CEN-60-48
48V
36 ~ 48V
1.3A
0 ~ 1.3A
62.4W
4.6Vp-p
43 ~ 53V
1 ~ 1.3A
CEN-60-54
54V
40.5 ~ 54V
1.15A
0 ~ 1.15A
62.1W
5Vp-p
49 ~ 58V
0.9 ~ 1.15A
RIPPLE & NOISE (max.)
Note.2
2Vp-p
CURRENT ADJ. RANGE
(SVR2)
3.75 ~ 5A
VOLTAGE TOLERANCE
Note.3
±10%
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
±3.0%
±5.0%
VOLTAGE ADJ. RANGE
(SVR1)
10.8 ~ 13.5V 13.5 ~ 17V
500ms / 230VAC 1200ms / 115VAC at full load
Note.4
90 ~ 295VAC
127 ~ 417VDC
47 ~ 63Hz
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
86%
87%
88%
89%
90%
90%
90%
91%
91%
0.8A/115VAC
0.4A/230VAC
0.3A/277VAC
COLD START 45A(twidth=85
μ
s measured at 50% Ipeak) at 230VAC
<0.75mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
14.5 ~ 17V 17.5 ~ 21V 22.8 ~ 26V 28 ~ 34V
34 ~ 38V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
-30 ~ +70℃ (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
℃
, 10 ~ 95% RH
±
0.03%/
℃
(0 ~ 50
℃
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL879, UL8750, CSA C22.2 No. 207-M89, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13, IP66, J61347-1, J61347-2-13 approved
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55015, EN61000-3-2 Class C (≧75% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria B
523.4Khrs min. MIL-HDBK-217F (25
℃
)
185*62.5*40.5mm (L*W*H)
0.6Kg;24pcs/15.4Kg/1.29CUFT
41 ~ 46V
47 ~ 52V
54 ~ 60V
59 ~ 65V
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Please refer to "DRIVING METHODS OF LED MODULE".
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
File Name:CEN-60-SPEC 2014-03-13
60W Single Output LED Power Supply
Power Factor Characteristic
Constant Current Mode
1.00
0.96
0.92
0.88
CEN-60
series
PF
0.84
0.80
0.76
0.72
0.68
0.64
50%
60%
70%
80%
90%
100%
(60W)
277Vac
230Vac
115Vac
LOAD
EFFICIENCY vs LOAD (48V Model)
CEN-60 series possess superior working efficiency that up to 91% can be reached in field applications.
94
90
86
82
78
74
70
66
62
58
54
50
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
EFFICIENCY (%)
277Vac
230Vac
115Vac
DRIVING METHODS OF LED MODULE
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.
Vo(%)
Constant
Current area
100
75
(min.)
Hiccup
Protection
50
100
Io (%)
Typical LED power supply I-V curve
File Name:CEN-60-SPEC 2014-03-13