Part Number

Search

240-0326-9PCA8K7-18K

Description
D Microminiature Connector, 9 Contact(s), Male, Crimp Terminal,
CategoryThe connector    The connector   
File Size166KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

240-0326-9PCA8K7-18K Overview

D Microminiature Connector, 9 Contact(s), Male, Crimp Terminal,

240-0326-9PCA8K7-18K Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Codecompli
ECCN codeEAR99
Other featuresSTANDARD: MIL-DTL-83513, WIRE LENGTH: 18 INCH
Connector typeD MICROMINIATURE CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
DIN complianceNO
empty shellNO
Filter functionYES
IEC complianceNO
MIL complianceYES
Manufacturer's serial number240-032
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsWITH CABLE ASSEMBLY
Shell materialALUMINUM ALLOY
Housing sizeA
Termination typeCRIMP
Total number of contacts9
Base Number Matches1
Micro-D Filter Connectors
Pre-Wired Pigtails with Insulated Wire
G
Glenair’s Filtered Pigtail Micro-D's
provide EMI solutions
in a miniaturized M83513 Micro-D connector. These
connectors feature ceramic capacitor planar arrays
and ferrite inductors. Insulated wire is factory precision-
crimped to TwistPin contacts for superior reliability in
the most demanding environments.
Choose Pi or C Filter Arrays
in seven filter classes and
six layouts. Glenair filtered Micro-D connectors comply
with applicable MIL-DTL-83513 requirements and are
100% intermateable with standard connectors.
C
Choose 9 to 37 Contacts,
with standard cadmium or
nickel plating on the connector housing or choose
optional finishes such as gold or chem film.
HOW TO ORDER FILTER MICRO-D CONNECTORS WITH INSULATED WIRE PIGTAILS
Number
of
Contact
Contacts
Type
9
15
21
25
31
37
P
Pin
Series
240-032
Shell Finish
Aluminum Shell
Wire
Filter Gage
Filter Type Class (AWG)
C
C Filter
P
Pi Filter
Wire Type
Wire Color
1
White
2
Yellow
5
Color-Coded
Stripes Per
MIL-STD-681
(#24 and #26
gage only)
Wire
Length
Inches Hardware
18
Wire
Length In
Inches. “18”
Specifies
18 Inches.
1
2
4
5
6
– Cadmium
– Nickel
– Black Anodize
– Gold
– Chem Film
S
Socket
A 4
– #24
K
M22759/11
600 Vrms
B 6
– #26
Teflon
®
(TFE)
C 8
– #28
D
J
M22759/33
600 Vrms
E
Modified
F
Cross-Linked
G
Tefzel
®
(ETFE)
7
Ten Color
Repeat
Stainless Steel
Shell
3
Passivated
B
P
M
M1
S
S1
L
K
F
R
Sample Part Number
240-032
2
25
P
P
B
6
K
1
– 18
B
MICRO-D MOUNTING HARDWARE
B
P
M
M1
S
S1
L
K
F
R
Thru-Hole Jackpost Jackscrew Jackscrew Jackscrew Jackscrew Jackscrew Jackscrew Float Mount Float Mount
Order
Hardware
Separately
Removable
Includes Nut
and Washer
Hex Head
Removable
E-ring
Hex Head
Removable
E-ring
Extended
Slot Head
Removable
E-ring
Slot Head
Removable
E-ring
Extended
Hex Head
Non-
Removable
Slot Head
Non-
Removable
Extended
For Front
Panel
Mounting
For Rear
Panel
Mounting
© 2006 Glenair, Inc.
CAGE Code 06324/0CA77
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
F-7
E-Mail: sales@glenair.com
Micro-D
Filter
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Component List of 2011 Electronic Design Competition
[i=s]This post was last edited by paulhyde on 2014-9-15 09:46[/i]2011 National Undergraduate Electronic Design Competition List of basic instruments and main components 1. Basic Instrument List 20MHz ...
jbjhl504 Electronics Design Contest
Problems with program storage and PC pointer
Does K60 data storage in the program storage area mean specifying an address in the Flash address space: 0x00000000--0x00080000? Does K60 start from 0x00000000? What instructions are used to implement...
zysun20010300 NXP MCU
Please recommend, is there any domestic dual-channel H-bridge that can drive motors with an operating voltage of 12V or above?
Intended to replace DRV8847PWPR...
sparks- Motor Drive Control(Motor Control)
Asking for advice on FIR filter IP issues
It is very convenient to configure FIR filter using Altera's IP core, but there is one question I don't understand:The input is unsigned 16-bit data, and the IP configuration tells that the output is ...
xieqiang FPGA/CPLD
How to shorten the startup time of VXWORKS?
Please help: PENTIUM CPU, from system power on to VXWORKS initialization, that is, entering the usrAppInit entry, takes about two minutes, which is too long. How can I shorten this time? Thank you ver...
625wangpeng Real-time operating system RTOS
Problems with porting tinyos to gains 3
Can tinyos be ported to gains 3? I mainly want to apply the functions of the java tools in tinyos. If it is possible, how can I do it? Can you give me a general idea, such as which things to modify, e...
greatdoor Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2184  399  2920  49  2027  44  9  59  1  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号