EEWORLDEEWORLDEEWORLD

Part Number

Search

516-120-501-120

Description
Multiway Rack and Panel Connector,
CategoryThe connector    The connector   
File Size379KB,3 Pages
ManufacturerEDAC
Environmental Compliance
Download Datasheet Parametric View All

516-120-501-120 Overview

Multiway Rack and Panel Connector,

516-120-501-120 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145224755142
Reach Compliance Codeunknown
ECCN codeEAR99
YTEOL7.2
body width1.525 inch
subject depth0.798 inch
body length2.75 inch
Body/casing typePLUG
Connector typeMULTIWAY RACK AND PANEL CONNECTOR
Contact point genderHERMAPHRODITIC
empty shellNO
Filter functionNO
insulator materialDIALLYL PHTHALATE
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
OptionsGENERAL PURPOSE
Rated current (signal)8.5 A
GuidelineUL
Total number of contacts120
UL Flammability Code94V-0

516-120-501-120 Preview

516
SERIES
Rack And Panel Connectors
Features:
0.150” (3.81mm) contact spacing x 0.130” (3.30mm) or 0.150” (3.81mm) row spacing with staggered grid
Plug and receptacle in 20, 38, 56, 90 and 120 contact sizes
Edacon hermaphroditic contact mating design
Contact termination options include crimp, P.C. tail, wire hole and wire wrap
Mating and unmating simplified with use of actuating screws
Optional covers with side or top entry cable clamp in plastic or metal material available for all connector sizes
Versatile metal cover design permits assembly or disassembly after cabling is complete plus cable entry style flexibility
Actuating screws, locknuts, polarizing hardware, covers and contacts suitable for either plug or receptacle
Polarizing hardware adjustable for 288 mating combinations
Tools available for contact installation, removal, crimping and polarizing changes
RoHS Compliant & UL Certified
Specifications:
Insulator Material
Color
Contact Material
Contact Plating
Current Rating
Contact Resistance
Dielectric Withstanding Voltage
Insulation Resistance
Operating Temperature
Operating Temperature
Insertion & Withdrawal Force
Example Part Number:
Series
Total Number of Contacts
Contact Code
Style and Material
Cover Code
Hardware Code
Diallyl Phthalate, Thermoplastic Polyester or Polycarbonate UL 94V- 0
Green or Grey (For 120 Pin Only)
Copper Alloy
Gold Plating over Nickel over entire contact
8.5 amps
10 milliohms maximum
2000 V AC rms at sea level
5000 megaohms minimum
-40°C to +125°C (Diallyl Phthalate Only)
-40°C to +105°C
2 to 16 oz (0.56 to 4.45N) per contact position
516-038-500-212
Series:
516
Total Number of Contacts:
020, 038, 056, 090 or 120
Contact Code:
000
500
501
520
540
541
542
Style & Material:
1
2
3
4
5
6
Description:
No Contacts Assembled
Wire Hole
Taper Tail
P.C. Tail
Wire Wrap
Wire Wrap
Wire Wrap
Style:
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Tail Size:
------------
.110 x .024 (2.79 x 0.61)
.110 x .024 (2.79 x 0.61)
.025 x .024 (0.64 x 0.61)
.050 x .024 (1.27 x 0.61)
.026 x .024 (0.66 x 0.61)
.050 x .024 (1.27 x 0.61)
Insulator Material:
Green Diallyl Phthalate
Green Diallyl Phthalate
Grey Polycarbonate
Grey Polycarbonate
Green Polyester
Green Polyester
Tail Length "G":
------------
.245 (6.22)
.245 (6.22)
.215 (5.46)
.600 (15.24)
.620 (15.70)
.790 (20.07)
Cover Code:
0
1
2
3
4
5
6
Hardware Code:
0
1
2
5
6
Description:
No Cover Assembly
Plastic Cover, Top Entry Standard Clamp
Plastic Cover, Side Entry Standard Clamp
Plastic Cover, Top Entry Large Clamp
Plastic Cover, Side Entry Large Clamp
Metal Cover, Side Entry
Metal Cover, Top Entry
Description:
No Hardware
Actuating Screw & Polarizing Hardware
Locknut & Polarizing Hardware
Actuating Screw with No Polarizing Hardware
Locknut with No Polarizing Hardware
www.edac.net
customerservice@edac.net
516
SERIES
Rack And Panel Connectors
Ordering Code Notes:
1) Crimp contacts are also available for 516 series connectors. Contacts may be ordered separately for
pre-wired or select position assembly.
Part Number
516-290-500
516-290-501
516-290-520
516-290-540
516-290-541
516-290-542
516-290-590
516-294-571
Description
Wire Hole
Taper Tail
P.C. Tail
Wire Wrap
Wire Wrap
Wire Wrap
Crimp (Loose)
Crimp - 1800 Contact
Per Reel
Silhouette
Crimp Characteristics
Contacts and Crimp Tool Accommodate from 28AWG to 18AWG, Solid or Stranded Conductor
Diameters from .012 (0.30) to .049 (1.25) and an Insulation diameter up to 0.074 (1.88)
Multiple Smaller Gauge Wires may be Crimped Together
Crimp Resistance from 0.5 Milliohms (18AWG) to 1.5 Milliohms(28AWG)
Crimp Tensile Strength for Wire Sizes:
18AWG - 40 lbs (178 N)
20AWG - 25 lbs (111 N)
22AWG - 15 lbs (67 N)
24AWG - 10 lbs (44 N)
26AWG - 5 lbs (22 N)
28AWG - 3 lbs (13 N)
Polarizing Codes
Polarizing Hardware Changes allow 288 Mating Combinations
Standard Code Supplied for Plugs PG1G1, for Receptacle RS1S1.
Connectors with Special Polarizing Codes Available upon Special Request
2) For contact installation, removal and crimping tools, please contact EDAC.
3) Grey Polycarbonate and Polyester insulator material is not available for 120 pin size connector.
120 pin size connector can only be supplied in DAP (Green and Grey). 120 pin part number ends with
3XX or 4XX are supplied in grey DAP.
4) 20 pin connector cover will not accept the length of the wire wrap contacts
5) Plastic covers with large clamps are only available for 38 and 56 pin sizes only
6) Metal covers with side entry may be converted to top entry by removing side plate and changing clamp
orientation
7) Covers may be ordered separately
8) Insulator design prevents improper mating of individual plug and receptacle. Polarizing hardware
enables specific plug and receptacle combinations
Example Polarizing Code:
Type of Connector
P - Plug, R - Receptacle
Large Diameter Hardware
G - Guidepin (at Contact Position "A" end)
H - Guidepin (at Last Contact Position end)
S - Socket (at Contact Position "A" end)
T - Socket (at Last Contact Position end)
Position of large Diameter Keyway - 1 Through 6
P G 4 S 2
Small Diameter Hardware (Opposite end From Large Diameter)
G - Guidepin, S - Socket
Position of Small Diameter Keyway - 1 Through 6
This Example mates with Code RS4G2
www.edac.net
customerservice@edac.net
516
SERIES
Rack And Panel Connectors
www.edac.net
customerservice@edac.net
Procedure for evaluation of relay protection and safety automatic devices operation
1. The scope of statistical evaluation of relay protection operation of power system is: 1..1 Generators, phase regulators, transformers, busbars, reactors, motors, capacitors, lines (including cables...
jek9528 Industrial Control Electronics
Phase-locked loop design
[i=s] This post was last edited by paulhyde on 2014-9-15 09:16 [/i] :) :) :) Typical control scheme design of phase-locked loop, hehe [[i] This post was last edited by xiaoxiaoha on 2009-8-17 15:55 [/...
xiaoxiaoha Electronics Design Contest
ECG PCB
The ECG acquisition board I drew has no problem with simulation, but the waveform is not right at all. Because I don't have an oscilloscope, I can only use a computer. ont][/size][/color][color=#33333...
远方RF PCB Design
MSP430f5529 car source code
[i=s]This post was last edited by Hot Ximixiu on 2020-11-3 22:06[/i]The MCU source program is as follows://**********************************************************************************// Author:w...
火辣西米秀 Microcontroller MCU
About the precise delay of Xilinx Nexys3 board under Microblaze
How to write the delay function for precise delay under Xilinx Nexys3 board Microblaze? For example, how to write delay_us() and delay_ms() functions when the system clock is 50M or 100M?...
hjl240 FPGA/CPLD
Does anyone have any good information on ov7725 image recognition?
I never thought I would use a camera before, and now I suddenly have to adjust the camera and I'm confused! If you have good information, please share it with each other:Cry::Cry: Please help...
pangzimengnan Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2878  2638  699  1930  1351  58  54  15  39  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号