T496C476M010CT63107280

Description
Tantalum Capacitor, Polarized, Tantalum (dry/solid), 10V, 20% +Tol, 20% -Tol, 47uF, 2412
CategoryPassive components    capacitor   
File Size880KB,20 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Environmental Compliance  
Download Datasheet Parametric View All

T496C476M010CT63107280 Overview

Tantalum Capacitor, Polarized, Tantalum (dry/solid), 10V, 20% +Tol, 20% -Tol, 47uF, 2412

T496C476M010CT63107280 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1308290505
package instruction, 2413
Reach Compliance Codecompliant
Country Of OriginMexico
ECCN codeEAR99
YTEOL6.92
Other featuresESR IS MEASURED AT 100KHZ; MIL-PRF-55365
capacitance47 µF
Capacitor typeTANTALUM CAPACITOR
dielectric materialsTANTALUM (DRY/SOLID)
ESR1200 mΩ
high2.5 mm
JESD-609 codee3
leakage current0.0047 mA
length6 mm
Installation featuresSURFACE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, EMBOSSED PLASTIC, 13 INCH
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)10 V
size code2312
surface mountYES
Delta tangent0.06
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
Terminal shapeJ BEND
width3.2 mm
T496 High Reliability Alternative Fused MnO
2
,
DLA Drawing 04053
Overview
The T496 High Reliability Series (HRA) with a built-in fuse
design, provides excellent protection from short circuit
conditions in applications where damaging high fault
currents exist.
The T496 HRA meets the MIL-PRF-55365 requirements and is
suitable for use in high reliability applications, incorporating
an intensive testing and screening protocol that is
customizable depending on specific customer requirements.
The T496 HRA is available in standard and low ESR.
Tantalum Surface Mount Capacitors – High Reliability
Benefits
• Meets or exceeds EIA standard 535BAACC
• Patented fuse assembly, which protects against
short circuit mode
• DLA Drawing 04053 available*
• Established Reliability Weibull Options B, C, or D
• 100% surge current testing options per MIL–PRF–55365
available
• Fuse actuation, 25°C: within 1 second at fault currents of
4 amps and higher
• Continuous current capability of 0.75 amps
• Post actuation resistance, 25°C: 10 MΩ, minimum
• Test tabs on side of case bypass of the capacitor element to
allow direct testing of the fuse assembly
• Standard termination SnPb
• MSL Level 1
* Defense Logistics Agency (DLA), previously identified as DSCC
Applications
Typical applications include decoupling and filtering in computing, telecommunications, defense, and industrial end
applications requiring built-in fuse capability.
Environmental Compliance
RoHS compliant when ordered with 100% Sn solder.
• Halogen-free
• Epoxy compliant with UL94 V-0
• Molded Epoxy complies for outgassing testing under ASTM E 595.
Built Into Tomorrow
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
T2062_T496_HRA • 10/12/2021
1
Let's see the picture
I drew a PT100 temperature measurement circuit myself. I hope the experts can give me some guidance....
白手梦想家 Analog electronics
EEWORLD University ---- Open source H.265 IP core
Open source H.265 IP core : https://training.eeworld.com.cn/course/4855H.265 Video Encoder IP Core is an open source H.265 hardware video encoder that implements most of the functions of H.265 (or HEV...
抛砖引玉 FPGA/CPLD
Urgent, FPGA programming help
I want to write a program for dynamic display of digital tubes, but after downloading it to the board (epm240t100c5), it always won’t run. I don’t know what the problem is. I would like to ask for gui...
大梦将启 FPGA/CPLD
Compile error command line error D8004 '/I' requires an argument
Dear experts, the above error occurs during compilation. What is going on? Thank you for your answer!...
jeffleee Embedded System
Design and application of modular inverter power supply
Design and application of modular inverter power supply Abstract: This paper discusses the application scenarios and design features of modular inverter power supply, and takes the inverter power supp...
zbz0529 Power technology
Why can't I enter the TIMER capture interrupt? (1114)
I am new to 1114, and I wrote a program but cannot enter the interrupt. I would like to ask for help from my colleagues. I want to use the timer capture function, and I would be grateful if you can gi...
brave_guarder NXP MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1084  1355  1662  705  1296  22  28  34  15  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号