Part Number

Search

T541D227M006DT6720

Description
Tantalum Capacitor, Tantalum (solid Polymer),
CategoryPassive components    capacitor   
File Size1MB,25 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

T541D227M006DT6720 Overview

Tantalum Capacitor, Tantalum (solid Polymer),

T541D227M006DT6720 Parametric

Parameter NameAttribute value
Objectid7138755073
package instruction,
Reach Compliance Codecompliant
Country Of OriginUSA
ECCN codeEAR99
YTEOL7.9
Other featuresESR AND RIPPLE CURRENT IS MEASURED AT 100KHZ
capacitance220 µF
Capacitor typeTANTALUM CAPACITOR
dielectric materialsTANTALUM (SOLID POLYMER)
ESR6 mΩ
high2.8 mm
JESD-609 codee3
leakage current0.139 mA
length7.3 mm
Installation featuresSURFACE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, EMBOSSED PLASTIC, 7 INCH
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)6.3 V
ripple current1629.75 mA
size code2917
surface mountYES
Delta tangent0.1
Terminal surfaceMatte Tin (Sn)
Terminal shapeJ BEND
width4.3 mm
KEMET Organic Capacitor (KO-CAP
®
) – High Reliability
T540/T541 High Reliability Series (HRA)
Polymer Electrolytic, 2.5 – 63 VDC
Overview
The KEMET Organic Capacitor (KO-CAP) is a solid
electrolytic capacitor with a conductive polymer cathode
capable of delivering very low ESR and improved
capacitance retention at high frequencies. KO-CAP
combines the low ESR of multilayer ceramic, the high
capacitance of aluminum electrolytic, and the volumetric
efficiency of tantalum into a single surface mount package.
Unlike liquid electrolyte-based capacitors, KO-CAP
has a very long operational life and high ripple current
capabilities.
The HRA Polymer Electrolytic offers the same performance
advantages as other KO-CAP series with screening options
associated with high reliability (Hi-Rel) applications.
These HRA grade components offer several surge current
screening options. The recommended application derating
for these capacitors is 10 – 20%, rendering them suitable for
application voltages from 2.5 to 63 VDC.
These are the first polymer electrolytic capacitors available
with failure rate options as defined by KEMET's KO-CAP
Reliability Assessment method. This method utilizes
accelerated conditions (voltage and temperature) applied to
board-mounted samples to assess long term device reliability.
The failure rates available are B (0.1% per 1,000 hours), C
(0.01% per 1,000 hours), and D (0.001% per 1,000 hours).
The KO-CAP Reliability Assessment method was developed
as a result of over 10 years of research and is described in
numerous papers available on www.kemet.com.
Benefits
• Approved for DLA Drawing 04051/04052
• DLA Drawing 04052 Part Numbers with Surge Current Option B are approved under ESA/EPPL part 2
• B, C, and D failure rates available
• 100% accelerated steady state aging
• High frequency capacitance retention
• Improved humidity capability 85°C/85% RH, 1.0 V
R
(in black color epoxy) available
• Very low ESR values down to 5 mΩ
• Surge current testing options
• Volumetrically efficient
• EIA standard case sizes
• KEMET's KO-CAP Reliability Assessment method
Built Into Tomorrow
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard
Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com
T2077_T540-541 • 10/18/2021
1
Are Decoupling Capacitors Really What You Need?
[align=left][font=微软雅黑][size=4]Before I started working as an applications engineer, I was an IC test development engineer. One of my projects was to characterize an I2C temperature sensor. After writ...
okhxyyo Power technology
Development board application
...
bihu Microcontroller MCU
Usage and precautions of common electrical measuring instruments
Common measuring instruments used by electricians include megohmmeters, multimeters and clamp ammeters. If these instruments are not used correctly or are slightly negligent during measurement, the me...
hxqhit Test/Measurement
Question + Looking for a method to separate AC and DC
One of my previous projects only tested the size and phase of AC, but not the DC component, so I used a transformer to isolate it. Now I want to add a test for the DC component. [color=Red]That is, no...
mylsf Integrated technical exchanges
Current measurement principles and products
Current measurement is widely used in circuit design, and its main fields are divided into three categories: in measurement, electric meters are used to measure current; in protection, current often h...
kandy2059 Test/Measurement
How to access the high address range (greater than 0xFFFF) of MSP430
From the structure diagram of 430, we can see that the address bus MAB is 16 bits, and the maximum addressing space is 64k. Some chips have internal Flash larger than 64k. How is the range above this ...
w_shun Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 759  1409  644  2151  381  16  29  13  44  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号