EEWORLDEEWORLDEEWORLD

Part Number

Search

231-104-09M11-4SD-02

Description
Circular Connector Adapter, 4 Contact(s), Aluminum Alloy, Female-Male
CategoryThe connector    The connector   
File Size446KB,1 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

231-104-09M11-4SD-02 Overview

Circular Connector Adapter, 4 Contact(s), Aluminum Alloy, Female-Male

231-104-09M11-4SD-02 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
Other featuresSTANDARD: MIL-DTL-38999
Body/casing typeRECEPTACLE-PLUG
Connector typeCIRCULAR CONNECTOR ADAPTER
Contact point genderFEMALE-MALE
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial number231-104-09
Mixed contactsNO
Installation typePANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL
Shell materialALUMINUM ALLOY
Total number of contacts4
Base Number Matches1
for MIL-DTL-38999 Series I Type
Shell Size
09
11
13
15
17
19
21
23
25
Connector Series
231
-
D38999 Series I Type
Connector Type
104
-
Env. Bulkhead
Feed-Thru
Insert Arrangement
Per MIL-DTL-38999 Series I
MIL-STD-1560
Contact Termination
P
- Pin on Plug Side
S
- Socket on Plug Side
231
-
104
-
09 M 11
-
35 P N
-
01
Shell Style
09
- Jam Nut Mount Plug/
Receptacle Gender Changer
Alternate Key
Position
A, B, C, D
(N = Normal)
Panel Accomodation
01
- .0625″ (Min) .125″ (Max)
02
- .0625″ (Min) .250″ (Max)
03
- .0625″ (Min) .500″ (Max)
Panel
Accomodation
Connector Material and Finish
M
- Aluminum / Electroless Nickel
NC
- Aluminum / Zinc-Cobalt
NF
- Cad / O.D. Over Electroless Nickel (1000hr Salt Spray)
ZN
- Aluminum Zinc-Nickel Olive Drab
MT
- Aluminum / Ni-PTFE 1000 Hour Grey
TM
AL
- Aluminum / Pure Electrodeposited Aluminum
Insert Arrangement per
MIL-DTL-38999, Series l
MIL-STD-1560
TABLE I: CONNECTOR DIMENSIONS
SHELL
SIZE
09
11
13
15
17
19
21
23
25
A THREAD
CLASS 2A
.688-24 UNEF
0.813-20 UNEF
1.000-20 UNEF
1.125-18 UNEF
1.250-18 UNEF
1.375-18 UNEF
1.500-18 UNEF
1.625-18 UNEF
1.750-18 UNS
B DIA
MAX
.573(14.6)
C
MAX
.900(22.9)
D
HEX
E
FLATS
F DIA
±.005(0.1)
.703(17.9)
.827(21.0)
G
+.000-.005
(0-0.1)
.699(17.8)
.769(19.5)
.955(24.3)
.875(22.2) 1.062(27.0)
.701(17.8) 1.030(26.2) 1.000(25.4) 1.250(31.8)
.851(21.6) 1.205(30.6) 1.188(30.2) 1.375(34.9) 1.015(25.8)
.976(24.8) 1.325(33.7) 1.312(33.3) 1.500(38.1) 1.140(29.0) 1.084(27.5)
1.101(28.0) 1.450(36.8) 1.438(36.5) 1.625(41.3) 1.265(32.1) 1.208(30.7)
1.208(30.7) 1.565(39.8) 1.562(39.7) 1.812(46.0) 1.390(35.3) 1.333(33.9)
1.333(33.9) 1.690(42.9) 1.688(42.9) 1.938(49.2) 1.515(38.5) 1.459(37.1)
1.458(37.0) 1.795(45.6) 1.812(46.0) 2.062(52.4) 1.640(41.7) 1.580(40.1)
1.583(40.2) 1.920(48.8) 2.000(50.8) 2.188(55.6) 1.765(44.8) 1.709(43.4)
1.
Material/finish:
Shell assembly, coupling nut, jam nut, lock ring—Aluminum
Alloy, See Table II
Contacts—Copper alloy/gold plate
Bayonet pins, wave washer—CRES/passivate
APPLICATION NOTES
O-Ring, interfacial and peripheral seals—silicone/N.A.
Insulators—High grade rigid dielectric/N/A.
Ground Ring—Beryllium copper/gold plate
Metric Dimensions (mm) are indicated in parentheses.
2.
© 2008 Glenair, Inc.
www.glenair.com
CAGE CODE 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
E-5
Bulkhead
Feed-Thrus
231-104-09
Jam Nut Mount Environmental
Plug/Receptacle Bulkhead Feed-Thru
E
evc simulator cannot be used
I installed EVC and the modeler, why can't I use it without the simulator?...
ft1826119 Embedded System
Regarding the serial communication problem between the microcontroller and the PC. Urgent!
When the microcontroller communicates with the PC via the serial port, the data transmitted is correct at the beginning, but after working for a while, errors occur in the transmitted data. When a fix...
pipihaoyun Embedded System
Could you guys please give me some advice, is there something wrong with the interrupt handling of ucos?
The interrupt handling process of ucos ii is as follows (directly on the code):{OSIntEnter();//Call ISR...OSIntExit ();return;}OSIntExit (){#if OS_CRITICAL_METHOD == 3 /* Allocate storage for CPU stat...
小pxp Real-time operating system RTOS
DC Level Shifting - TI Solutions
In multi-level systems, DC level conversion is very common, which is directly related to the success or failure of a system design. TI's solutions for DC level conversion are quite good, such as SN74L...
clark Analogue and Mixed Signal
Iar 2.2 error when compiling release version, please help
Building configuration: gas - ReleaseError[e16]: Segment DATA16_Z (size: 0xb9 align: 0x1) is too long for segment definition. At least 0x38 more bytes needed. The pro××em occurred while processing the...
shen001 Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1263  514  1627  1625  2666  26  11  33  54  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号