Part Number

Search

FCPT-225191315

Description
Fiber Optic Device, 1460nm Min, 1500nm Max, SC/APC Connector
CategoryWireless rf/communication    Optical fiber   
File Size429KB,2 Pages
ManufacturerLaser Components USA Inc.
Environmental Compliance
Download Datasheet Parametric View All

FCPT-225191315 Overview

Fiber Optic Device, 1460nm Min, 1500nm Max, SC/APC Connector

FCPT-225191315 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid1337771163
Reach Compliance Codeunknown
Communication standardsTELCORDIA-GR-1209
Connection TypeSC/APC CONNECTOR
Fiber typePMF
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Maximum operating wavelength1500 nm
Minimum operating wavelength1460 nm
Nominal operating wavelength1480 nm
minimum return loss50 dB
1×2(2×2) Fused
Polarization Maintaining
Standard Fiber Tap
(patent pending)
Product Description
The standard-sized fused polarization maintaining fiber tap comes with
low excess loss, high extinction ratio, high optical power handling and
Telcordia GR-1209 compliant test. It has wide range of applications such
Features
Low Excess loss
High Extinction Ratio
High Power Handling
Telcordia GR-1209
Compliant
as optical amplifier, power monitoring, telecomm system and testing
equipment.
Performance Specifications
Hybrid PM Fiber Tap
Operation Wavelength
Port Configuration
Excess Loss (Typical)
Excess Loss (Maximum)
PER for Through Port (Minimum)
Return Loss* (Minimum)
Directivity* (Minimum)
Operating Power (Maximum)
≤0.2
≤0.3
≥20
≥50
≥55
≤2
-40 ~ +85
-50 ~ +85
Specification
Premium
1×2
≤0.3
≤0.5
≥17
A grade
Unit
nm
1550/1480/1310
±
20
dB
dB
dB
dB
dB
W
o
C
o
C
Applications
Optical Amplifier
Power Monitoring
Telecomm System
Testing Equipment
Operating Temperature
Storage Temperature
Package Type
∅3.0
x L54
mm
* Test at central wavelength only
All specification are based on slow-axis alignment and without connector
LASER COMPONENTS GmbH
Werner-von-Siemens-Str. 15, 82140 Olching, Germany, Phone: +49 8142 2864 0, Fax: +49 8142 2864 11, info@lasercomponents.com

Recommended Resources

Title: How to force the pin state of TI DSP's ePWM?
When using EV in 2812, you can directly write EVx.ACTRx to directly control the forced high and forced low of PWM output. How should I configure it on the device using ePWM so that it can be forced hi...
paradoxfx Microcontroller MCU
Seeking RF wake-up solution
Looking for RF wake-up solution, 125KHz low frequency or high frequency is fine, as long as it can wake up. Wake-up distance <1.2m; antenna area is about 1.2mX1.2m; if you have a solution, please cont...
Andrewyancn RF/Wirelessly
System clock
MCLK represents the CPU operation and system clock. 430 executes a simple instruction in one clock cycle. Why does it take the same time to execute the same code when MCLK=REFOCLK (32768HZ) and MCLK=X...
jacken.bool Microcontroller MCU
Question about calculating high level time of input capture
[i=s] This post was last edited by electrics on 2016-9-26 00:33 [/i] while(1) { if(((TIM2->SR&0X0001)==1)&&((TIM2->CCER & 0X0002)==0X0002)) //Falling edge trigger and judgment is reaching the maximum ...
electrics stm32/stm8
Interface Technology Simulation Test
Single-choice questions 1. The transmission mode in which the microprocessor only starts the peripherals without intervening in the transmission process is _________ mode. A. Interrupt B. DMA C. Query...
a79571843 Embedded System

Popular Articles

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2215  1644  1952  2474  2210  45  34  40  50  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号