EEWORLDEEWORLDEEWORLD

Part Number

Search

326203ERTDA10F100328VCC

Description
Power/Signal Relay, DPDT, Momentary, 0.02A (Coil), 28VDC (Coil), 560mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
CategoryMechanical and electronic products    relay   
File Size345KB,4 Pages
ManufacturerSTPI Siege Social
Download Datasheet Parametric View All

326203ERTDA10F100328VCC Overview

Power/Signal Relay, DPDT, Momentary, 0.02A (Coil), 28VDC (Coil), 560mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,

326203ERTDA10F100328VCC Parametric

Parameter NameAttribute value
Objectid1058180899
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPANEL MOUNTABLE
body width26 mm
body height25.7 mm
Body length or diameter26 mm
Maximum coil current (DC)0.02 A
Coil power560 mW
Coil resistance1400 Ω
Maximum coil voltage (DC)28 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load10A@115VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
JESD-609 codee3
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
Maximum operating temperature105 °C
Minimum operating temperature-55 °C
physical size26mm x 26mm x 25.7mm
Relay actionMOMENTARY
Relay functionDPDT
Relay typePOWER/SIGNAL RELAY
sealHERMETICALLY SEALED
surface mountNO
Terminal surfaceTIN
Termination typeSOLDER
326 RT Type A
2
RT
-
DPDT
/10
A
RELAIS
TEMPORISE
HERMETIQUE 2RT/10 A*
HERMETICALLY SEALED
TIME DELAY
RELAY DPDT/10 Amps*
* 2 A avec brochages différents/2 Amps with different pin out
CARACTERISTIQUES GENERALES
Temporisation
Time-delay
GENERAL CHARACTERICS
Retard à l'enclenchement, au déclenchement, monostable
Time-delay on operate, on release, monostable
Temporisation fixe de 0,08 à 2 000 s ou ajustable par résistance extérieure : Cf gammes de temps
Time-delay, fixed time from 0,08 to 2000 s or ajustable by external resistor : See time ranges
Précision sur la temporisation
Timing accuracy
2 % de -40 à +85°C - 10% au delà
2% from -40 to +85°C - 10% beyond
Combinaison des contacts
Contact arrangement
2 RT
DPDT
Pouvoir de coupure 28 Vcc - 1 5 V/400 Hz - Durée de vie
1
Contact rating 28 Vdc - 115 V/400 Hz - Operating life
Circuit résistif
Resistive load
10 A - 100 000 manœuvres
10 Amps - 100 000 operations
Circuit inductif (L/R = 5 ms)
Inductive load (L/R = 5 ms)
8 A - 20 000 manœuvres
8 Amps - 20 000 operations
Circuit moteur
Motor load
4 A - 100 000 manœuvres
4 Amps - 100 000 operations
Circuit lampe
Lamp load
2 A - 100 000 manœuvres
2 Amps - 100 000 operations
Tension d'utilisation
Operating voltage
28 Vcc (18 à 32 Vcc)
28 Vdc (18 to 32 Vdc)
Masse
Weight
< 70 g
< 70 g
Normes applicables en annexe
See appendice for applicable specifications
ENVIRONNEMENT
Température de fonctionnement
Temperature range
ENVIRONMENT
-55° à +105°C
- 55° to +105°C
Température de stockage
Storage temperature
-65° à +1
25°C
-65° to +125°C
Tenue aux vibrations
Resistance against vibrations
30 g sin de 30 à 3 000 Hz / Aléatoire : 0,4 g
2
/Hz - 50 - 2 000 Hz
30 g sin from 30 to 3 000 Hz / Random : 0,4 g
2
/Hz - 50 - 2 000 Hz
Tenue aux chocs
Shocks resistance
100 g - 6 ms 1/2 sinus 3 axes
100 g - 6 ms 1/2 sinus 3 axes
Accélération
Acceleration
1 g 3 axes
5
15 g 3 axes
Taux de fuite
Leak rate
1.10
-8
cm
3
/sec
1.10
-8
cm
3
/sec
58 Av. Claude VELLEFAUX - 75010 PARIS - FRANCE
326 RT2 1/4
117
Tel : 33.(0)1.42.03.94.20 - Fax : 33.(0)1.42.03.52.85 - www.stpigroup.com
【PLC based on IoT】---Testing RPI-400 performance based on AI
[i=s]This post was last edited by cpsiot on 2022-7-23 12:58[/i]It is a bit of a waste to use RPI-400 as the HMI part. Today, I will test the AI performance. If it is OK, I can do the AI recognition pa...
cpsiot DigiKey Technology Zone
Urgent!!! How to convert a floating point number into a string
As the title says, now we need to convert a floating point number into a string and display it on LCD1602. It seems that the sprintf function cannot be used on the microcontroller. How can we solve th...
求大神们帮忙 51mcu
Newly purchased MSP430 LaunchPad development board
Experienced people please teach me, I'm a rookie......
海绵seny丶 Microcontroller MCU
Why can't my 1602 receive the clock signal from 430? 1602 can't display normally
[size=5][color=#ff0000]Using four-line drive method:[/color][/size] #include #define uchar unsigned char #define uint unsigned int const uchar tab_1[16]="Hello Msp430"; const uchar tab_2[16]=" 1602tes...
qinkaiabc Microcontroller MCU
Question: Is the PDF output by Smart PDF in Altium a 1:1 PCB?
I want to print out the PCB. Is the PDF output by Smart PDF in Altium a 1:1 PCB?...
william228 PCB Design
Commonly used transistors, triode data
Commonly used transistors, triode data...
fighting Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 869  2656  494  793  1003  18  54  10  16  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号