BG020-21G-0640-0300-1040-N-D

Description
Board Connector, 21 Contact(s), 1 Row(s), Male, Straight, Solder Terminal,
CategoryThe connector    The connector   
File Size166KB,1 Pages
ManufacturerGlobal Connector Technology
Environmental Compliance
Download Datasheet Parametric View All

BG020-21G-0640-0300-1040-N-D Overview

Board Connector, 21 Contact(s), 1 Row(s), Male, Straight, Solder Terminal,

BG020-21G-0640-0300-1040-N-D Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid314684894
Reach Compliance Codecompliant
ECCN codeEAR99
body width0.098 inch
subject depth0.409 inch
body length2.1 inch
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU ON NI
Contact completed and terminatedTin (Sn) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialCOPPER ALLOY
contact modeRECTANGULAR
Contact resistance20 mΩ
Contact styleSQ PIN-SKT
Dielectric withstand voltage600VAC V
Insulation resistance1000000000 Ω
insulator materialNYLON
JESD-609 codee3
Manufacturer's serial numberBG020
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number1
Number of rows loaded1
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
PCB contact patternRECTANGULAR
Plating thickness10u inch
Rated current (signal)3 A
GuidelineUL
reliabilityCOMMERCIAL
Terminal length0.118 inch
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts21
2.50
H
Number of
Contacts
Dimensions
A
2.54
5.08
7.62
10.16
12.70
15.24
17.78
20.32
22.86
25.40
27.94
30.48
33.02
35.56
38.10
40.64
43.18
45.72
48.26
B
5.08
7.62
10.16
12.70
15.24
17.78
20.32
22.86
25.40
27.94
30.48
33.02
35.56
38.10
40.64
43.18
45.72
48.26
50.80
Number of
Contacts
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Dimensions
A
50.80
53.34
55.88
58.42
60.96
63.50
66.04
68.58
71.12
73.66
76.20
78.74
81.28
83.82
86.36
88.90
91.44
93.98
96.52
99.06
B
53.34
55.88
58.42
60.96
63.50
66.04
68.58
71.12
73.66
76.20
78.74
81.28
83.82
86.36
88.90
91.44
93.98
96.52
99.06
101.60
2.54
B ±0.38
A ±0.25
0
1.
Ø
2
2.54
Recommended PCB Layout
2
3
4
5
6
7
8
9
2° Max. Sway & Toe
(Either Direction At The top )
G
2.54
0.64 sq pin
C±0.2
10
11
12
F
2.54
13
14
15
E±0.2
16
17
18
E
2.54
19
20
D±0.2
D
Ordering Grid
BG020
XX X
XXXX
XXXX
XXXX
X
X
Request Samples
and Quotation
No. of Contacts
02 to 40
Specifications
规格
C
Material
物料
Insulator
绝缘½
:
Standard
标准
: Polyamide, Nylon 6T, UL94V-0
Options
可选
: Polyester, LCP, UL94V-0
Polyester, PBT, UL94V-0
Contact
接触
: Copper Alloy
Plating
电镀
Contact
接触
: See ordering grid
Electrical
电气
Current Rating
电流额定值
: 3 Amp
Contact Resistance
接触电阻值
: 20 mΩ max.
Insulation Resistance
绝缘电阻值
: 1000 MΩ min.
Dielectric Withstand Voltage
寒耐电压
: 600 V AC
B
Mechanical & Environmental
机械
&
环境
Operating Temperature
工½温度
: -40°C to +105°C
Soldering Process
可焊性
Nylon 6T (Standard
标准物料
)
IR Reflow
回流焊
: 260°C for 10 sec.
Wave
波峰焊
: 230°C for 5-10 sec
Manual Solder
人工焊接
: 350°C for 3-5 sec
LCP (Option
可选物料
)
IR Reflow
回流焊
: 260°C for 10 sec.
Wave
波峰焊
: 250°C for 5-10 sec.
Manual Solder
人工焊接
: 350°C for 3-5sec
PBT (Option
可选物料
)
(not suitable for hi-temp process
不适合高温处理
)
Manual Solder
人工焊接
: 330°C for 3-5sec
Mates with
配套之母座
(Subject to Pin Length
在端子长度适合的条件下
)
BG090
BG095
BG096
BG100
BG115
BG125
BG130
BG135
BG205
Contact Plating
A = Gold Flash All Over
(Standard)
B = Selective Gold Flash Contact Area/
Tin On Tail
C = Tin All Over
G = 10µ" Gold Contact Area/Tin On Tail
I = 30µ" Gold Contact Area/Tin On Tail
Dimension C
(1/100mm) (Post Height)
0640 = 6.40mm
(Standard)
Or specify Custom Post Height
eg. 0250 = 2.50mm
Packing Options
B = Plastic Box
(Standard)
D = Tube
E = Tube with Cap
Insulator Material
N = Nylon 6T
(Standard)
P = PBT
L = LCP
Dimension E
(1/100mm) (Stack Height)
1040 = 10.40mm
(Standard)
Or specify Dimension E
eg. 0508 = 5.08mm (minimum)
If lower stacking heights required
contact GCT for lower profile
insulator options
Dimension D
(1/100mm) (Tail Length)
0300 = 3.00mm
(Standard)
Or specify Custom Footprint Width
eg. 0250 = 2.50mm
Part Number
Product Description
BG020
Drawing Date
A
30th October 2006
2.54mm Pitch Elevated Pin Header, Single Row,
Through-Hole, Vertical
Tolerances
(Except as Noted)
Length
Angle
BG110
BG145
By
Detail
Revision
Date
AJO
1
2
3
4
5
Minimum
X.° ± 5°
X. ± 0.30
Dim. E Added
X.X° ± 2°
X.X ± 0.20
E1
X.XX ± 0.15 X.XX° ± 1°
16/01/15
X.XXX ± 0.10 X.XXX° ± 0.5°
Units:
Metric (mm)
C
7
3rd Angle Projection
This drawing is confidential and
copyright of Global Connector
Technology, Ltd (GCT).
This drawing must not be copied
or disclosed without written
consent. E & OE
Global Connector Technology
GC
Drawn By
AJO
www.gct.co
Not to
Scale
Sheet No.
1/1
6
8
MPS gives benefits | Order online at the mall, get a JD card, and 8,000 yuan worth of gifts are waiting for you!
Event has ended Due to the impact of the epidemic, the list of winners will be announced later. Once the list of winners is confirmed, we will immediately notify the winning netizens to claim their pr...
EEWORLD社区 Power technology
In-depth analysis of T BOX system solution: charging and discharging management
[align=left]Section 2 Charge and Discharge Management[/align] [align=left]Under normal circumstances, VBAT will charge the backup battery while supplying power to the load; when encountering an emerge...
alan000345 TI Technology Forum
Research on multi-channel flyback converter based on NCP1200A
Abstract: The principle of the pulse width modulation current mode controller NCP1200A for low power general offline power supply is introduced, and the advantages of this controller are further illus...
binghuoshaonian Power technology
Understanding Systick_config priority setting NVIC_SetPriority
The function for setting the module interrupt priority in the Systick module initialization configuration function (Systick_config) is: NVIC_SetPriority((SysTick_IRQn, (1__NVIC_PRIO_BITS) - 1);The par...
xinbako stm32/stm8
How to disable a menu item in WinCE?
As the title says, what API function can be used to achieve this function? Can you give me some advice?...
阔步1981 Embedded System
Frequency division PLC program ladder diagram
In many control situations, it is necessary to divide the signal. The following uses the two-frequency division program shown in Figure 5-16 as an example to illustrate how PLC achieves frequency divi...
eeleader Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 38  2859  2451  814  1050  1  58  50  17  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号