EEWORLDEEWORLDEEWORLD

Part Number

Search

800Z-GF3245B-K3

Description
Zero-Force Touch Buttons
File Size145KB,4 Pages
ManufacturerRockwell Automation / Allen-Bradley
Download Datasheet View All

800Z-GF3245B-K3 Overview

Zero-Force Touch Buttons

Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Specifications
Standards
Approvals
Power Supply
Relay Output
Transistor Output
Power Consumption
Relay Output
Transistor Output
Outputs
Relay Output
Transistor Output
Output Ratings
Relay Output
Transistor Output
Min. Switched Current/
Voltage (Relay Output)
Pollution Degree
Operating Temperature
Humidity
Enclosure Protection
Material
Housing/Guard Valox
357
Gaskets BUNA-N
Relay Contacts AgSnO
Any position
5 wire (single common)
4 wire (single common)
10-40V DC, 20-30V AC, or 85-264V AC
10-30V DC
1.44W, 19.2VA
100mA at 24V DC = 2.23W (no load)
1 N.O. & 1 N.C.
PNP or NPN
See Load Life Curves
150mA
8mA/5V DC
2
-25°C to +55°C (-13° to +131°F)
95% RH
IP66 (NEMA 4/4X/13), 1200 psi
washdown
EN574, EN954-1, IEC/EN60947-5-1,
IEC/EN60204-1
cULus, C-Tick, and CE marked for all
applicable directives
Description
The general purpose Bulletin 800Z Zero-Force Touch Buttons are
designed for use by machine control systems requiring the use of
two hands. An interlinked sensor surface weaves two capacitive
sensors in offset planes for superior product sensitivity.
The 800Z touch buttons are ergonomically designed for ease of
operation. No force is required to operate the switch; simply
touching the surface of the switch will initiate an output. The 800Z
can detect the hand though most industrial gloves.
The contour of the 800Z touch buttons serves two purposes; it
easily conforms to the shape of the hand while helping prevent
defeatability when two-hand control is needed.
Two bi-coloured diagnostic LEDs provide guidance during operation.
The power/fault LED blinks at different rates to provide diagnostic
information to the user. The 800Z detects the presence of a hand
during power-up, noise, and conductive film build-up over time.
Mounting
Cable
Features
Zero Force to operate
Ergonomic design
EMC protection
Diagnostic LEDs
Electrical Life
EM-Relay inductive load See Load Life Curves
Vibration
1.5mm (0.06in) 10-55Hz
Shock
100g,11ms half-sine
Load Life Curves for General Purpose Product Line
Relay Output—Maximum DC Load Breaking Capacity
300
200
100
DC Voltage
Relay Output—Electrical Endurance
10
250V AC
10
Resistive Load
Operations
6
50
40
30
20
10
0.1 0.2 0.5
10
5
cosϕ = 1
cosϕ = 0.7
cosϕ = 0.4
1
2
5
10
20
10
4
0
1
2
3
4
5
6
7
8
DC Current (A)
Switching Current (A)
11-2
Ask netizens about ARM interview questions
ARM President Tudor Brown will step down in March and come to Beijing next week. We will have the opportunity to spend nearly an hour with the old man. Does anyone have any questions of interest?...
凯哥 Talking
Recruiting chip design director/engineer/intern
A technology company in Beijing Recruiting chip design director/engineer/intern positions 1. Responsible for the design of radio frequency, microwave and millimeter wave integrated circuit chips; 2. D...
小糖人 Recruitment
Paid advice on DSP video processing
I want to run an algorithm for grayscale processing of videos on a DSP board, using ping-pong buffering for data transmission and processing, but I have not been able to debug it. The DSP uses the DM6...
hahayuanjun DSP and ARM Processors
Interrupt Deferred Procedure Call DPC Problem?
I want to use DPC to set an event when the driver receives an interrupt from the PCI card. Why does the computer freeze after the driver has been loaded? The relevant code is as follows: #pragma PAGED...
诗心蝴蝶 Embedded System
Why do socket functions behave differently in the emulator and in actual hardware?
I'm new to wince, and my development environment is pb5.0, evc4.0. I'm using the example TCP client and server in "EVC Advanced Programming and Its Application Development". The target hardware is x86...
julyfeel Embedded System
See what this information means?
According to the tutorial of bbb burning, the serial port prints out this information, and the four lights are all off. Is the image being burned? [code]U-Boot SPL 2013.04-dirty (Jun 19 2013 - 09:57:1...
白丁 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 553  2529  2174  1375  2026  12  51  44  28  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号