EEWORLDEEWORLDEEWORLD

Part Number

Search

800Z-GF3245Y-K1

Description
Zero-Force Touch Buttons
File Size145KB,4 Pages
ManufacturerRockwell Automation / Allen-Bradley
Download Datasheet View All

800Z-GF3245Y-K1 Overview

Zero-Force Touch Buttons

Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Specifications
Standards
Approvals
Power Supply
Relay Output
Transistor Output
Power Consumption
Relay Output
Transistor Output
Outputs
Relay Output
Transistor Output
Output Ratings
Relay Output
Transistor Output
Min. Switched Current/
Voltage (Relay Output)
Pollution Degree
Operating Temperature
Humidity
Enclosure Protection
Material
Housing/Guard Valox
357
Gaskets BUNA-N
Relay Contacts AgSnO
Any position
5 wire (single common)
4 wire (single common)
10-40V DC, 20-30V AC, or 85-264V AC
10-30V DC
1.44W, 19.2VA
100mA at 24V DC = 2.23W (no load)
1 N.O. & 1 N.C.
PNP or NPN
See Load Life Curves
150mA
8mA/5V DC
2
-25°C to +55°C (-13° to +131°F)
95% RH
IP66 (NEMA 4/4X/13), 1200 psi
washdown
EN574, EN954-1, IEC/EN60947-5-1,
IEC/EN60204-1
cULus, C-Tick, and CE marked for all
applicable directives
Description
The general purpose Bulletin 800Z Zero-Force Touch Buttons are
designed for use by machine control systems requiring the use of
two hands. An interlinked sensor surface weaves two capacitive
sensors in offset planes for superior product sensitivity.
The 800Z touch buttons are ergonomically designed for ease of
operation. No force is required to operate the switch; simply
touching the surface of the switch will initiate an output. The 800Z
can detect the hand though most industrial gloves.
The contour of the 800Z touch buttons serves two purposes; it
easily conforms to the shape of the hand while helping prevent
defeatability when two-hand control is needed.
Two bi-coloured diagnostic LEDs provide guidance during operation.
The power/fault LED blinks at different rates to provide diagnostic
information to the user. The 800Z detects the presence of a hand
during power-up, noise, and conductive film build-up over time.
Mounting
Cable
Features
Zero Force to operate
Ergonomic design
EMC protection
Diagnostic LEDs
Electrical Life
EM-Relay inductive load See Load Life Curves
Vibration
1.5mm (0.06in) 10-55Hz
Shock
100g,11ms half-sine
Load Life Curves for General Purpose Product Line
Relay Output—Maximum DC Load Breaking Capacity
300
200
100
DC Voltage
Relay Output—Electrical Endurance
10
250V AC
10
Resistive Load
Operations
6
50
40
30
20
10
0.1 0.2 0.5
10
5
cosϕ = 1
cosϕ = 0.7
cosϕ = 0.4
1
2
5
10
20
10
4
0
1
2
3
4
5
6
7
8
DC Current (A)
Switching Current (A)
11-2
Which are the power lines in PCB wiring?
I set the width of the lines marked with 5V and 3.3V in the PCB according to the current value, but I have a question: although some lines do not have x.xV in the PCB board, they are connected to a co...
面纱如雾 PCB Design
Is there any expert welder? Also, please come in, moderator
Is there any expert welder? I am going to start welding 0805 and 28-pin TFP. Is there any expert who can give me some advice before I start? Hehe, thank you in advance! In addition, please help me sol...
flyingaway Embedded System
Why is there no response when checking the registers with axd?
Everyone, when I use axd to debug the program, I can't view the registers using memory. For example, when I view the GPGDAT register and enter 0x56000064, the memory address will become 0x0 again. Wha...
hhz520520 Embedded System
Urgent help, the s3c2440 development board keeps running away?
I made a 2440 board myself, with two SAMSUNG K4S511632D-UC75 64M SDRAM. Now it always crashes at the BOOTLOADER stage, either freezing during the countdown or crashing while reading the FLASH. I teste...
yunalps Embedded System
LVDS Converter IC
Professional agent provides LVDS conversion chip: LVDS TO TTL: 18bit, 24bit, 30bit TTL TO LVDS: 18bit, 24bit, 30bit LVDS/TTL to RSDS If you need it, please send an email to my email: iven.yang@163.com...
c51rf2 Embedded System
Is it possible to use CW single-step debugging to see the execution of the interrupt program?
I wrote an SCI receive interrupt and used CW single-step debugging, but there is a problem. After the interrupt is entered, there is a step to determine the receive status register. The value of this ...
socsic NXP MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1536  1610  1849  198  1963  31  33  38  4  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号