EEWORLDEEWORLDEEWORLD

Part Number

Search

802T-K1TPD

Description
Safety Limit Switches
File Size165KB,4 Pages
ManufacturerRockwell Automation / Allen-Bradley
Download Datasheet View All

802T-K1TPD Overview

Safety Limit Switches

Position Interlock Switches
Safety Limit Switches
802T Direct Opening Action NEMA-Style Switches
Specifications
Standards
EN954-1, ISO13849-1, IEC/EN60204-1,
NFPA79, EN1088, ISO14119, IEC/
EN60947-5-1, ANSI B11.19, AS4024.1
Cat. 1 Device per EN954-1
Dual channel interlocks suitable for Cat.
3 or 4 systems
cULus listed, CE marked for all
applicable directives and TUV for 2-
circuit models
NEMA 4, 6P, 12, 13 and IP67
-18°C to +110°C (0°F to +230°F)
-18°C to 60°C (0°F to 140°F)
-40°C to 121°C (-40°F to 250°F)
Category
Approvals
Enclosure Rating
Operating Temperature
Cable Versions Temperature
Storage Temperature
Description
Bulletin 802T Direct Opening Action limit switches have been
designed for use in control reliable applications and safety
applications per ISO 14119. These limit switches utilize the same
mounting dimensions as other NEMA style limit switches. The
rugged metal construction and plug-in body are designed for use in
harsh industrial environments.
Direct Opening Action assures that the normally closed contacts
open when the limit switch is actuated. This opening will occur even
in the event of a contact weld condition, up to 10 Newtons.
AC Contact Rating
(Maximum per Pole, 50 or 60Hz, 2 Circuits)
NEMA
Rating
Designation
Max
Max
Voltage
A
Make
Break
Continuous
Carrying
Current
VA
Make
Break
A600
AC-15
120
240
480
600
60
30
15
12
6.00
3.00
1.50
1.20
10
10
10
10
7200
7200
7200
7200
720
720
720
720
ATTENTION:
To ensure that the normally
closed (safety) contacts open, the limit
switch actuator must be displaced beyond
the point of Direct Opening Action (see
specifications).
Features
Direct opening action
Snap acting contacts
Rugged metal construction
Long life and reliability
Plug-in design
NEMA 6P/IP67 sealing
AC Contact Rating
(Maximum per Pole, 50 or 60Hz, 4 Circuits)
NEMA
Rating
Designation
Max
Max
Voltage
A
Make
Break
Continuous
Carrying
Current
VA
Make
Break
A300
120
240
60
30
6.00
3.00
10
10
7200
7200
720
720
DC Contact Rating (Maximum per Pole)
NEMA
Rating
Designation
A
Make
Break
Continuous
Carrying
Current
VA
Make
Break
Max
Voltage
Q300
Q300
DC 13
250
125
0.27
0.55
0.27
0.55
2.5
2.5
69
69
69
69
Typical Applications
Machine guards
Access gates and doors
Cranes or hoists
Transfer stations
Indexing tables
Robotic cells
Low Voltage DC
24V DC @ 1.1 Amps resistive load
802T Operating Levers
See the Limit Switches section of the
Sensors
catalogue.
7-14
Dad bought a flashlight yesterday, it's very fun~~~~
Yesterday, my dad bought a flashlight and had a lot of fun playing with it: 7 LED lights, two-position switch, one position can turn on four lights, and the other position can turn on seven lights. My...
soso Buy&Sell
High score solution! Experts please come in! How to load a module in a driver and use it (like a program loading a dll) [200 points]
I am developing a driver-based software that implements multiple functions. Based on various considerations (memory usage, easy scalability, etc.), I hope to encapsulate each function in a module (sys...
kangjianbo Embedded System
A radio that can "hear" its own voice
[i=s]This post was last edited by btty038 on 2021-6-8 22:04[/i]Wireless communications don’t provide ubiquitous coverage. We’ve all been there: calls get disconnected, web pages sometimes take a long ...
btty038 Robotics Development
AD reference power supply for dsp28335 and dsp2812
1. Does the reference power supply mean setting a voltage upper limit? For example, if the internal reference power supply is 3V, then when adin inputs 3V, 4095 is obtained. 2. There are three externa...
malicious Microcontroller MCU
SPI communication problem between omap3530 and mcp2515
I would like to ask you guys, after the MCU sends a reset command through SPI and then sends a read command, the data read is always 0? I have been working on it for a while, but it still doesn't work...
wolf372103 Embedded System
Are the electrical connections of 5438 and 5438A different? Are they directly interchangeable?
[i=s] This post was last edited by liujj05 on 2015-3-20 14:09 [/i] I saw on the Internet that the difference between 5438 and A is mainly that it is more stable and has an AD ref. But if I want to dir...
liujj05 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 262  1719  797  725  1402  6  35  17  15  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号