WIRE AND CABLE, FLEXIBLE CORD AND FIXTURE WIRE, 1 CONDUCTOR(S), 26AWG, 600V
55AC1813-26-9-9 Parametric
Parameter Name
Attribute value
Objectid
8148363667
Reach Compliance Code
unknown
YTEOL
8.5
Connector bracket type
WIRE AND CABLE
structure
STRANDED
diameter
2.01 mm
Jacket material
RADIATION-CROSSLINKED MODIFIED ETFE
Number of conductors
1
Maximum operating temperature
200 °C
Rated voltage
600 V
shield
YES
Wire gauge
26 AWG
Wire and Cable Names
FLEXIBLE CORD AND FIXTURE WIRE
55AC1813-26-9-9 Preview
SPECIFICATION CONTROL DRAWING
TITLE
55AC1813
Date
ONE CONDUCTOR CABLE, SHIELDED, JACKETED, GENERAL PURPOSE, 600 VOLT
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
COMPONENT WIRE - 55A0813
SHIELD - NICKEL-COATED COPPER
1-26-09
Revision
A
JACKET - RADIATION-CROSSLINKED,
MODIFIED ETFE
CABLE CONSTRUCTION DETAILS
PART NUMBER
1/
55AC1813-26-*
55AC1813-24-*
55AC1813-22-*
55AC1813-20-*
55AC1813-18-*
55AC1813-16-*
55AC1813-14-*
55AC1813-12-*
55AC1813-10-*
55AC1813-8-*
55AC1813-6-*
55AC1813-4-*
CONDUCTOR
SIZE
(AWG)
26
24
22
20
18
16
14
12
10
8
6
4
SHIELD
SIZE
(AWG)
38
38
38
38
38
38
38
38
38
38
38
36
JACKET THICKNESS
(inches)
MINIMUM
.006
.006
.006
.006
.006
.006
.006
.006
.006
.007
.007
.008
NOMINAL
.008
.008
.008
.008
.008
.008
.008
.008
.008
.009
.009
.010
OUTSIDE DIAMETER
(inches)
NOMINAL
.073
.078
.083
.091
.103
.110
.127
.144
.167
.230
.276
.351
MAXIMUM
.079
.084
.089
.098
.111
.118
.135
.152
.180
.249
.297
.374
MAXIMUM
WEIGHT
(lbs/1000 ft.)
5.9
6.9
8.2
10.3
13.8
16.1
22.3
30.3
44.1
81.3
118.
196.
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 3°C for 7 hours
BLOCKING: 200 ± 3°C for 6 hours
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz
FLAMMABILITY (Procedure 1): 3 seconds (maximum);
3 in. (maximum); no flaming of facial tissue
JACKET COLOR: White preferred
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in² (minimum)
JACKET FLAWS:
Spark Test, 1000 volts (rms)
Impulse Dielectric Test, 6.0 kV (peak)
NOTE: Nominal values are for information only.
Nominal values are not requirements.
LIFE CYCLE: 230 ± 3°C for 500 hours
LOW TEMPERATURE-COLD BEND: -65 ± 3°C for 4 hours
SHIELD COVERAGE: 90% (minimum)
VOLTAGE WITHSTAND TEST (Post Environmental):
1000 volts (rms), 60 Hz, 1 minute
PART NUMBER:
The “*” in the part numbers above shall be replaced by color code
designators with a dash separating the component wire color from the
jacket color.
1/
Example: AWG 20, white component wire; white jacket:
55AC1813-20-9-9
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/
COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
The TE logo, Tyco Electronics and Raychem are trademarks.