EEWORLDEEWORLDEEWORLD

Part Number

Search

PRD-3AY0-120

Description
PRD Series Power Relay
File Size514KB,5 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet View All

PRD-3AY0-120 Online Shopping

Suppliers Part Number Price MOQ In stock  
PRD-3AY0-120 - - View Buy Now

PRD-3AY0-120 Overview

PRD Series Power Relay

General Purpose Relays
Industrial Relays
PRD Series Power Relay
n
n
n
n
n
Potter & Brumfield
Contact ratings to 50 amps
Magnetic blowouts available for switching DC loads
Contact arrangement up to 2 form C (2CO)
1 Form C auxiliary switch available
UL class B insulation
Typical applications
Industrial controls, lighting
Approvals
UL E22575; CSA LR15734; VDE Reg.Nr.C144
Models with all screw terminals are UL Listed. Others are UL Recognized.
Technical data of approved types on request
Contact Data
1 and 2 Form A (NO); 1 and 2 Form C (CO);
1 Form X (NO-DM)
Rated voltage
600VAC,125VDC
Rated current
50A
Contact material
Ag, AgCdO, W
Min. recommended contact load
1A, 12VDC or 12VAC
Initial contact resistance
75mΩ Max
Initial voltage drop
75mV
Frequency of operation
7200 ops/hr
Operate/releases time max.
40/20ms
Bounce time max.
10ms
Contact ratings
Type
Load
UL 508
1)
Models with screws or quick connects for main terminals
Code Y, Ag, 1 pole
25A, 277VAC
1HP, 120VAC
2HP, 250VAC
10A, 600VAC
7A, 50VDC, resistive
Code Y, Ag, 2 pole
25A, 240VAC
20A, 277VAC
1HP, 120VAC
2HP, 250VAC
7A, 50VDC, resistive
10A, 600VAC
Code G, AgCdO, 1 pole
30A, 277VAC, resistive
1.5HP, 120VAC
2HP, 250VAC
10A, 600VAC
Code G, AgCdO, 2 pole
30A, 240VAC
20A, 277VAC
1.5HP, 120VAC
2HP, 250VAC
10A, 600VAC
Cycles
Contact arrangement
Contact ratings
(continued)
Type
Load
UL 508
1)
Models with screws or quick connects for main terminals
Code F, AgCdO, 1 pole
50A, 240VAC, general purpose
2)
30A, 277VAC, resistive
1.5HP, 120VAC
2HP, 250VAC
10A, 600VAC
Code F, AgCdO, 2 pole
50A, 240VAC, general purpose
2)
30A, 240VAC
20A, 277VAC
1.5HP, 120VAC
2HP, 250VAC
10A, 600VAC
Code H, Ag with magnetic blowout, 1 or 2 pole
20A, 125VDC
1/3HP, 125VDC
Code J, AgCdO with magnetic blowout, 1 or 2 pole
20A, 125VDC
1/3HP, 125VDC
Code N, W stationary with AgCdO movable, 1 or 2 pole
25A, 250VAC
1HP, 125VAC
2HP, 250VAC
UL 508
1)
Models with box lugs for main terminals
Code P, Ag, 1 form X
50A, 277VAC, general purpose
30A, 277VAC, ballast
15A, 277VAC, tungsten
102LRA, 17FLA, 240VAC
120LRA, 20FLA, 120VAC
1.5HP, 120VAC
3HP, 240VAC
Factory ratings
Models with box lugs for main terminals
Code R, Ag with magnetic blowout, 1 form X
60A, 28VDC, resistive
30A, 125VDC
Mechanical endurance
Cycles
20x10
3
100x10
3
100x10
3
100x10
3
100x10
3
20x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
2) In order to achieve 50A rating with Contact Code F, Termination Code 0 or A is required.
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
6x10
3
6x10
3
30x10
3
30x10
3
30x10
3
30x10
3
100x10
3
100x10
3
DC Coil, 1x10
6
ops.; AC Coil 5x10
5
ops.
1) Any PRD relay deviating electrically or physically from the standard models in the table is
not UL or CSA listed. All horsepower ratings are for single phase motors..
Auxiliary Snap-Action Switch Contact Data
Contact arrangement
Rating
Contact material
1 Form C (CO)
5A, 120VAC, 60 Hz., 25°C
Ag
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
How can I use 2132 to accurately measure time to ms?
Using the msp430 f2132 chip, I want to accurately time the device to the ms level. The test time error is very large, the timing is nearly 1/10 more than the actual actual time. Another question is, i...
desertriver Microcontroller MCU
Ask a simple question - STARM command rules
I have seen it somewhere before, but I can't find it now. Can anyone tell me what the 6 and 7 in T6 and T7 mean? STR731FV1T6 STR731FV2T7...
PP2008 stm32/stm8
About memory management of ecos
I want to learn about the memory management of the ecos operating system recently. I feel lost when reading the source code. For the fixed-size memory block management, I only see the definition of th...
jeff1115 Embedded System
Can anyone explain to me what's going on? I recently made another ds1302 perpetual calendar, but I still can’t read the numbers.
/*2015_11-02*/ #include #include "intrins.h" #define uint unsigned int #define uchar unsigned char #define lcd_date P0 #define delay5us(){_nop_();_nop_();_nop_();_nop_();_nop_();} uchar a ,miao,shi,fe...
18811707971 Linux and Android
MMU address mapping problem
ACTIVATEMMU ; The 1st Level Section Descriptors are setup. Initialize the MMU and turn it on. ; mov r1, #1 mcr p15, 0, r1, c3, c0, 0 ; Set up access to domain 0. mov r0, #0 ; ********I PLUS mcr p15, 0...
liangxu Embedded System
Newcomer Report
I'm new here. I'm particularly interested in microcontrollers. I'll trouble you in the future. It would be best if I had someone who could be my master....
依然存在 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2513  2413  53  1383  1952  51  49  2  28  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号