EEWORLDEEWORLDEEWORLD

Part Number

Search

4797.3115

Description
AC power entry modules 4797 appliance outlt 16a
CategoryThe connector    The connector   
File Size342KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

4797.3115 Overview

AC power entry modules 4797 appliance outlt 16a

4797.3115 Parametric

Parameter NameAttribute value
MakerSCHURTER
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time10 weeks
Other featuresSTANDARDS: IEC/EN 60320-2-2/J; UL 94V-0; CSA
Connector typeMAINS POWER CONNECTOR
Contact point genderFEMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings16/20A, 250VAC
Manufacturer's serial number4797
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Connectors (Inlets/Outlets)
https://www.schurter.com /PG07
4797
IEC Appliance Outlet J, Snap-in/Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
Snap-in version
Screw-on mounting
Type J
See below:
70° C
Approvals and Compliances
Characteristics
Description
-
-
-
-
Snap-in or screw-on mounting , from front side
Connector , Pin temperature 70 °C Protection class I
V-Lock notch standard
Safety of electrical appliances for household and similar purposes.
Meets the requirements for appliances in unattended use. This inclu-
des the enhanced requirements of glow wire tests acc. to IEC 60695-
2-12 and -13.
- Solder terminals or quick connect terminals
- Suitable for use in equipment according to IEC/UL 60950
Other versions on request
- Other panel thickness
- Variants in white color
- For protection class II
References
Weblinks
Substitute for type
0723; 5213; 5216
Alternative: version with integrated light pipes
4797-5
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite,
Landing Page
The integration of light pipes in the appliance outlet provides status indication in smart PDUs. See PDU Landing Page for more information.
Power Distribution Units
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
16 A / 250 VAC; 50 Hz
20 A / 250 VAC; 60 Hz
> 2.5 kVAC between L-N
> 3 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
Suitable for appliances with protection
class I or II acc. to IEC 61140
Solder terminals or quick connect ter-
minals
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
Type J acc. to IEC 60320-3
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection Class I
Allowable Operation Tempe-
rature
Insulation cover
Terminal
Panel Thickness S
Material: Housing
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: 4797
Approval Logo
Certificates
VDE Approvals
UL Approvals
CQC Approvals
Certification Body
VDE
UL
CQC
Description
Certificate Number: 40040106
UL File Number: E103791
CCC Certificate Number: 2016180204002357
Product standards
Connectors
1
How to modify the date and time of ESP8266
I would like to ask my friends who are playing with ESP8266 how to modify its date and time when there is no network. Since ESP8266 is automatically calibrated when there is a network, its time is 197...
hydyguo stm32/stm8
Network Development Notes 13_Udp Data Collection
1.UDP Socket Earlier we learned about TCP Socket and the collection and storage of TCP data. Now let's look at UDP Socket and the collection of UDP data. The UDP protocol runs on top of the IP protoco...
yuhua8688 Microcontroller MCU
Getting Started with Programming
This section introduces how to program and implement 1-2 simple demonstration programs. Hardware preparation: programming cable, expansion bracket board with sensorile core board installed, STM32-NUCL...
cz0842 MEMS sensors
How to build an application into an OS Image?
As the title says, I have checked the information and found many different opinions. I am deeply confused. I hope some friends can answer for me. Opinion 1: Add in config.bib: Subproject.exe $(_FLATRE...
copytang Embedded System
Qt Learning Road Chapter 12
[p=22, null, left][color=#555555][font=Tahoma, Helvetica, SimSun, sans-serif][size=14px][color=#333333][backcolor=rgb(247, 247, 247)][font=Tahoma, Arial, Helvetica, sans-serif]In the previous article ...
兰博 Embedded System
What knowledge do you need to learn for embedded software development?
RT~~~ Software development, not hardware oriented, do I need to learn MCU, ARM and the like? If I am interested in embedded software, what should I learn?...
wind518 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2735  269  2520  949  1888  56  6  51  20  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号