Connectors (Inlets/Outlets)
https://www.schurter.com /PG07
5098
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
F
70° C
H
See below:
70° C
Approvals and Compliances
Description
References
Weblinks
- Panel mount :
Screw-on mounting , from front side
- 1 Function :
- Connector , Pin temperature 70 °C , protection class I or II
- Solder terminals or quick connect terminals
We recommend for new applications the type
6600-3
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 4 kVAC between L-N
> 2 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 20 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Solder terminals or quick connect ter-
minals
PA6, black or grey, UL 94V-0
appliance inlet/-outlet
F acc. to IEC 60320-3 /
H UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I or II
Allowable Operation Tempe-
rature
IP-Protection
Insulation cover
Terminal
Material: Housing
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: 5098
Approval Logo
Certificates
VDE Approvals
UL Approvals
CSA Approvals
Certification Body
VDE
UL
CSA
Description
VDE Certificate Number: 40010295
UL File Number: E57445
CSA Certification Record: 27324
Product standards
Product standards that are referenced
Organization
Design
Designed according to
Designed according to
Designed according to
Designed according to
Standard
IEC 60320-1
IEC 60320-3
UL 498
CSA C22.2 no. 42
Description
Appliance couplers for household and similar general purposes
Appliance couplers for household and similar general purposes
Standard for Attachment Plugs and Receptacles
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Connectors
1
5098
Application standards
Application standards where the product can be used
Organization
Design
Designed for applications acc.
Standard
IEC/UL 60950
Description
Connectors (Inlets/Outlets)
https://www.schurter.com /PG07
IEC 60950-1 includes the basic requirements for the safety of information
technology equipment.
Compliances
The product complies with following Guide Lines
Identification
Details
CE declaration of conformity
Initiator
SCHURTER AG
Description
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
EU Directive RoHS 2011/65/EU
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
RoHS
China RoHS
REACH
SCHURTER AG
SCHURTER AG
SCHURTER AG
Dimensions [mm]
50.4
25.7
40
R
9
R 10
40
32.2
24.7
- 0
24.5
29
+0.2
Length of the terminal please find at the order code configuration table
ø
2
3.
R
3
32.4
- 0
+0.2
5
Config. Code
5098
|
-
|
H
|
-
|
A
|
B
|
C
|
0-
|
D
|
-
|
E
|
The characters are placeholders for the correspondingly keys of selections from the key tables.
5098
|
-
|
H
|
-
|
A
|
B
|
C
|
0-
|
D
|
-
|
E
|
= Type
Type
protection class II
protection class I
Configuration
key
B
X
5098
|
-
|
H
|
-
|
A
|
B
|
C
|
0-
|
D
|
-
|
E
|
= Terminals
Terminal N
solder terminal
Blade terminal (6.3 x 0.8 mm)
Symbols similar as in table A
Configuration
key
1
9
5098
|
-
|
H
|
-
|
A
|
B
|
C
|
0-
|
D
|
-
|
E
|
= Terminals
Terminal L
Configuration
key
1
5098
|
-
|
H
|
-
|
A
|
B
|
C
|
0-
|
D
|
-
|
E
|
= Terminals
Terminal Ground
without terminal
solder terminal
Configuration
key
0
1
9
solder terminal
Blade terminal (6.3 x 0.8 mm)
9
Blade terminal (6.3 x 0.8 mm)
Symbols similar as in table A
2
Connectors
Connectors (Inlets/Outlets)
https://www.schurter.com /PG07
5098
5098
|
-
|
H
|
-
|
A
|
B
|
C
|
0-
|
D
|
-
|
E
|
= Style
Configuration
key
A
B
Style
flange with countersunk holes
flange with through holes
Configuration
key
1
2
5098
|
-
|
H
|
-
|
A
|
B
|
C
|
0-
|
D
|
-
|
E
|
= Color
Color
Black
Grey
All Variants
Type
protection class II
protection class I
protection class I
protection class I
protection class I
Terminals L / N
Blade terminal (6.3
x 0.8 mm)
solder terminal
solder terminal
Blade terminal (6.3
x 0.8 mm)
Blade terminal (6.3
x 0.8 mm)
Terminal Ground
without terminal
solder terminal
solder terminal
Blade terminal (6.3
x 0.8 mm)
Blade terminal (6.3
x 0.8 mm)
Color
Black
Black
Grey
Black
Grey
Style
flange with countersunk holes
flange with countersunk holes
flange with countersunk holes
flange with countersunk holes
flange with countersunk holes
Features
-
-
-
-
-
Config. Code
5098-B-9900-A-1
5098-X-1110-A-1
5098-X-1110-B-1
5098-X-9990-A-1
5098-X-9990-B-1
Order Number
6182.0027
6182.0028
6182.0030
6182.0031
6182.0032
█
█
The listet variants should be available from stock Other versions on request
www.schurter.com/contact
█
Most Popular.
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Packaging unit
Mating Inlets/Plugs
50 Pcs
Category / Description
Plug Overview complete
IEC Plug E, Cord Connector (Rewireable), Straight, max. cable Diameter 8.5 mm
IEC Plug E, Cord Connector (Rewireable), Straight, max. Cable Diameter 10 mm
IEC Plug E, Cord Connector (Rewireable), Straight
IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 8.5 mm
IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm
Plug further types to 5098
4732
4735
9009
4733
4736
...
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Connectors
3
10.09.2018