• Industry standard design with switching currents of 10A to 21A
• Widely used for applications where long life expectancy and
high reliability is required.
• Choose from a variety of levers, terminals and operating forces.
• Right and Left Barrier options are available for the V-21 and
V-16 models
• Heat resistant versions of the V-15 and V-10 are available.
• RoHS Compliant
Ordering Information
■
Model Number Legend
V-
1 2 3
1.
-
4 5 6 7
-
8
-
9
4. Contact Form
COM Terminal, Bottom position:
1:
SPDT
2:
SPST-NC
3:
SPST-NO
COM Terminal, Side position:
4:
SPDT
5:
SPST-NC
6:
5.
SPST-NO
9.
7.
Maximum Operating Force
6:
400 gf
5:
200 gf
4:
100 gf
Note:
These OF
values
are for
the pin plunger models.
Ratings
21:
21 A at 250
VAC
16:
16 A at 250
VAC
15:
15 A at 250
VAC
11:
11 A at 250
VAC
10:
10 A at 250
VAC
Contact Gap
None: 1 mm (F gap)
G:
0.5 mm (G gap)
Actuator
None: Pin plunger
1:
Short hinge lever
2:
Hinge lever
3:
Long hinge lever
4:
Simulated roller lever
5:
Short hinge roller lever
6:
Hinge roller lever
2.
8.
Special Purpose
None: Standard
T:
Heat resistive
(V-15 and
V-10,
only)
Mounting Hole Size
None: 3.1 mm
K:
2.9 mm
3.
Terminals
A:
Solder terminals
C2:
Quick-connect terminal (#187)
C:
Quick-connect terminal (#250)
6. Insulation Barrier
None:
Without
Barrier
R:
Right-hand
barrier
L:
Left-hand
barrier
(Barriers available for
V-21
and
V-16,
only)
Note:
Consult Omron regarding nomenclature combinations and part numbers
not found in this datasheet.
Snap Action Switch
V
121
■
Available Combinations
Thermoplastic case
Model
Rated Current
OF
COM
Insulation
Heat
terminal
Barrier Resistance Terminal Symbol
position
Bottom
No
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Heat
resistant
(150°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Yes
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Side
No
Standard
(80°C)
Solder terminals (A)
Quick-connect
terminals (#187)(C2)
Quick-connect
terminals (#250)(C)
Note: 1.
❍:
Available model.
Consult OMRON for specific models with standard approval.
V-21
21 A
400 gf
V-16
16 A
400 gf
200 gf
V-11
11 A
100 gf
Thermosetting case
V-15
15 A
400 gf
200 gf
V-10
10 A
200 gf
100 gf
---
---
❍
---
---
---
---
---
❍
---
---
❍
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
❍
❍
❍
---
---
---
---
---
---
---
---
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
❍
❍
❍
❍
❍
---
---
---
---
❍
❍
---
■
List of Models
Thermoplastic Case
21 A (OF: 400 gf)
Without barrier
Common
terminal Contact
position form
Bottom
SPDT
SPST-NC
SPST-NO
SPDT
Right-hand barrier
Without barrier
Left-hand barrier
Terminal style Actuator
Quick-connect
(#250) (C)
V-21-1C6
V-21-1CR6
V-21-2CR6
V-21-3CR6
V-211-1CR6
V-212-1CR6
V-213-1CR6
V-214-1CR6
V-215-1CR6
V-216-1CR6
V-21-1CL6
V-21-2CL6
V-21-3CL6
V-211-1CL6
V-212-1C6
V-213-1CL6
V-214-1CL6
V-215-1CL6
V-216-1CL6
V-21-2C6
V-21-3C6
V-211-1C6
V-212-1C6
V-213-1C6
V-214-1C6
V-215-1C6
V-216-1C6
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Example: V-21G2-1C6-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
122
Snap Action Switch
V
16 A (OF: 200 gf)
Without barrier
Common
terminal Contact
position form
Bottom
SPDT
Right-hand barrier
Without barrier
Left-hand barrier
SPST-NC
SPST-NO
SPDT
Terminal style
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
V-16-1A5
V-16-1C25
V-16-1C5
V-16-2A5
V-16-2C25
V-16-2C5
V-16-3A5
V-16-3C25
V-16-3C5
V-161-1A5
V-161-1C25
V-161-1C5
V-162-1A5
V-162-1C25
V-162-1C5
V-163-1A5
V-163-1C25
V-163-1C5
V-164-1A5
V-164-1C25
V-164-1C5
V-165-1A5
V-165-1C25
V-165-1C5
V-166-1A5
V-166-1C25
V-166-1C5
V-16-1AR5
V-16-1C2R5
---
V-16-2AR5
V-16-2C2R5
---
V-16-3AR5
V-16-3C2R5
---
V-161-1AR5
V-161-1C2R5
---
V-162-1AR5
V-162-1C2R5
---
V-163-1AR5
V-163-1C2R5
---
V-164-1AR5
V-164-1C2R5
---
V-165-1AR5
V-165-1C2R5
---
V-166-1AR5
V-166-1C2R5
---
V-16-1AL5
V-16-1C2L5
---
V-16-2AL5
V-16-2C2L5
---
V-16-3AL5
V-16-3C2L5
---
V-161-1AL5
V-161-1C2L5
---
V-162-1AL5
V-162-1C2L5
---
V-163-1AL5
V-163-1C2L5
---
V-164-1AL5
V-164-1C2L5
---
V-165-1AL5
V-165-1C2L5
---
V-166-1AL5
V-166-1C2L5
---
11 A (OF: 100 gf)
Without barrier
Common
terminal
position
Bottom
Contact form
SPDT
Terminal style
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
A
C2
C
Actuator
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
V-11-1A4
V-11-1C24
V-11-1C4
V-111-1A4
V-111-1C24
V-111-1C4
V-112-1A4
V-112-1C24
V-112-1C4
V-113-1A4
V-113-1C24
V-113-1C4
V-114-1A4
V-114-1C24
V-114-1C4
V-115-1A4
V-115-1C24
V-115-1C4
V-116-1A4
V-116-1C24
V-116-1C4
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Examples: 1) V-16G3-1C25-K 2) V-11G-1A4-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
Snap Action Switch
V
123
Thermosetting Case
Standard models - 15 A / 10 A
Common Contact
terminal
form
position
Bottom
SPDT
Terminal style
A
C2
C
A
C2
A
C2
C
A
Actuator
15 A
200 gf
200 gf
V-10G-1A5-K
V-10G-1C25-K
—
V-10G-2A5-K
V-10G-2C25-K
V-10G-3A5-K
V-10G-3C25-K
—
V-10G-4A5-K
V-10G-5A5-K
V-10G-6A5-K
V-10G1-1A5-K
V-10G1-1C25-K
V-10G2-1A5-K
V-10G2-1C25-K
V-10G3-1A5-K
V-10G3-1C25-K
V-10G4-1A5-K
V-10G4-1C25-K
V-10G5-1A5-K
V-10G5-1C25-K
V-10G6-1A5-K
—
V-15G-1A5-K
V-15G-1C25-K
V-15G-1C5-K
V-15G-2A5-K
V-15G-2C25-K
V-15G-3A5-K
V-15G-3C25-K
V-15G-3C5-K
V-15G-4A5-K
V-15G-5A5-K
V-15G-6A5-K
V-15G1-1A5-K
V-15G1-1C25-K
V-15G2-1A5-K
V-15G2-1C25-K
V-15G3-1A5-K
V-15G3-1C25-K
V-15G4-1A5-K
V-15G4-1C25-K
V-15G5-1A5-K
V-15G5-1C25-K
V-15G6-1A5-K
V-15G6-1C25-K
10 A
100 gf
V-10G-1A4-K
V-10G-1C24-K
—
V-10G-2A4-K
V-10G-2C24-K
V-10G-3A4-K
V-10G-3C24-K
—
V-10G-4A4-K
V-10G-5A4-K
V-10G-6A4-K
V-10G1-1A4-K
V-10G1-1C24-K
V-10G2-1A4-K
V-10G2-1C24-K
V-10G3-1A4-K
V-10G3-1C24-K
V-10G4-1A4-K
V-10G4-1C24-K
V-10G5-1A4-K
V-10G5-1C24-K
V-10G6-1A4-K
V-10G6-1C24-K
Pin plunger
SPST-NC
SPST-NO
Side
Bottom
SPDT
SPST-NC
SPST-NO
SPDT
A
C2
A
C2
A
C2
A
C2
A
C2
A
C2
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
For SPST-NC and SPST-NO with levers consult Omron.
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
Heat Resistant Models (Up to 150°C) - 15 A / 10A
Common
terminal
position
Bottom
Contact
form
SPDT
Terminal style
Solder Terminals
(A)
Actuator
15 A
200 gf
V-15-1A5-T
V-151-1A5-T
V-152-1A5-T
V-153-1A5-T
V-154-1A5-T
V-155-1A5-T
V-156-1A5-T
10 A
100 gf
V-10-1A4-T
V-101-1A4-T
V-102-1A4-T
V-103-1A4-T
V-104-1A4-T
V-105-1A4-T
V-106-1A4-T
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: 1.
Add “G” to the part number in the appropriate location to obtain a 0.5 mm contact gap. Add “-K” to the part number in the appropriate
location to obtain 2.9 mm mounting holes. Add “C2” to the part number in the appropriate location to obtain versions with #187 quick-
connect terminals. Example: 1) V-15G1-1C25-T-K
2.
Not
all combinations are available. Consult Omron regarding nomenclature combinations and part numbers not found in this datasheet.
124
Snap Action Switch
V
Specifications
■
Ratings
(reference values)
Type
Rated voltage
Non-inductive load
Resistive load
Lamp load
NC
NO
NC
NO
21 A
3A
21 A
5A
14 A
5A
0.6 A
0.1 A
0.3 A
0.05 A
16 A
2A
16 A
4A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
15 A
2A
15 A
4A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
11 A
1.5 A
11 A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
1.5 A
10 A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
Inductive load
Inductive load
Motor load
NC
NO
NC
NO
12 A
4A
12 A
7A
12 A
5A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
3A
10 A
6A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
10 A
3A
10 A
6A
10 A
4A
0.6 A
0.1 A
0.3 A
0.05 A
6A
2A
6A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
6A
2A
6A
3A
6A
3A
0.6 A
0.1 A
0.3 A
0.05 A
V-21
V-16
V-15
V-11
V-10
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
250 VAC
8
VDC
30 VDC
125 VDC
250 VDC
Note: 1.
The above current values are the normal current values of models with a contact gap of 1 mm (gap F), which vary with the normal current
values of models with a contact gap of 0.5 mm (gap G).
2.
Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3.
Lamp load has an inrush current of 10 times the steady-state current.
4.
Motor load has an inrush current of 6 times the steady-state current.
5.
The ratings values apply under the following test conditions: Ambient temperature: 20±2°C, Ambient humidity: 65±5%, Operating frequency: 30 operations/min
■
Approved Standards
UL1054 (File No. E41515)
CSA C22.2 No.55 (File No. LR21642)
Rated voltage
125 VAC
250 VAC
125 VDC
250 VDC
V-21
21 A, 1/2 HP
V-16
16 A, 1/2 HP
V-15
15 A, 1/2 HP
0.6 A
0.3 A
V-11
11 A, 1/3 HP
V-10
10 A, 1/3 HP
EN 61058-1 (File No. 129608, VDE approval)
Rated voltage
250 VAC
V-21
20 (4) A
V-16
16 (4) A
V-11
11 (3) A
EN 61058-1 (File No. T9451451, TÜV Rheinland approval)
Rated voltage
250 VAC
250 VDC
V-15
15 A
0.3 A
V-10
10 A
Testing conditions: 5E4 (50,000 operations), T105 (0°C to 105°C)
Testing conditions: 5E4 (50,000 operations), T85 (0°C to
Abstract: Aiming at the application of high-speed A/D converter ( ADC ) in a certain signal processor , the hardware platform of the digital signal processor is used, pure sinusoidal signal is used as...
Dear friends: In SPI slave mode, CPU polling can receive data, and it is correct, but configuring it for interrupt reception has improved the interrupt interrupt configuration code: [code]void Setup_S...
There are many problems that you will encounter when learning Thread. Since the information is relatively closed and few people use it, it is difficult to find some problems through the documents (the...
I believe everyone is familiar with the principle, but it takes a lot of interest to really put it into practice. I'm going to show you how to make your own low-power wireless charging circuits that w...