EEWORLDEEWORLDEEWORLD

Part Number

Search

TMCJD6ST1640Y

Description
basic / snap action switches snap
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size200KB,6 Pages
ManufacturerAll Sensors
Environmental Compliance  
Download Datasheet Parametric View All

TMCJD6ST1640Y Online Shopping

Suppliers Part Number Price MOQ In stock  
TMCJD6ST1640Y - - View Buy Now

TMCJD6ST1640Y Overview

basic / snap action switches snap

TMCJD6ST1640Y Parametric

Parameter NameAttribute value
ManufactureC&K Components
Product CategoryBasic / Snap Action Switches
RoHSYes
Factory Pack Quantity1
TM Series
Miniature Snap-acting Switches
Features/Benefits
Broad range of operating forces available
Wide variety of actuator and terminal styles
Cost-effective solution
Typical Applications
Pumps and motors
White goods
Consumer appliances
Specifications
CONTACT RATING: From low level* to 15 AMPS @ 250 V AC.
ELECTRICAL LIFE: 150,000 cycles at 15 AMPS @ 250 V AC, models
with 150 grams operating force. 350,000 cycles at 10 AMPS @
250 V AC, models with 75 grams operating force.
INSULATION RESISTANCE: 1,000 M ohms min.
DIELECTRIC STRENGTH: 1,000 Vrms min. @ sea level.
OPERATING TEMPERATURE: –67ºF to 302ºF (–55ºC to 150ºC).
OPERATING FORCE: 50, 75 and 150 grams at actuator available;
refer to chart for lever style forces.
MOUNTING: Torque screws 2-5 in/lbs.
* Low Level=conditions where no arcing occurs during switching, i.e., 0.4 VA max. @
20 V AC or DC max.
Materials
SWITCH HOUSING: Thermoplastic or general purpose phenolic
(UL 94V-0).
ACTUATOR BUTTON: Thermoplastic (UL 94V-0).
SPRING: Copper alloy.
PIVOT: Brass alloy.
MOVABLE CONTACTS: Gold alloy for ratings 1 AMP @ 125 V AC
or less. Fine silver for ratings greater than 1 AMP @ 125 V AC.
STATIONARY CONTACTS: Gold alloy for ratings 1 AMP or less.
Fine silver for ratings greater than 1 AMP.
TERMINALS: Brass alloy for ratings up to 10 AMPS @ 250 V AC.
Copper alloy for 15 AMPS @ 250 V AC ratings.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
J
Snap-acting
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages J-12 through J-16. For additional options not shown in catalog, consult Customer Service Center.
Available extended electrical life per UL 1054, rated for 100,000 operations, consult factory.
T M
Series
TM
SP, Mom.
Operating Force
CG
2.65 oz./75 grams
CJ
5.29 oz.,/150 grams
CF
1.76 oz./50 grams
Electrical Rating
D6
1O A @ 125 & 250 V AC; 1/3 HP @ 125 & 25O V
AC;1/2 A @ 125 V DC; 1/4 A @ 250 V DC
G6
15 A @ 125 & 250 V AC; 1/4 A @ 250 V DC;
1/2 A @ 125 V DC; 1/2 HP @ 125 & 250 V AC;
3 A @ 125 V AC “L”
F5
1 A @ 125 V AC; 1 A @ 30 V DC
H3
5 A @ 250 V AC; 1/6 HP @ 125 & 25O V AC
Mounting Style
S
Standard
V
Metric
Actuator
P00
Pin plunger
A10
.81" lever roller, high force
A15
1.34" lever roller, high force
A20
1.02" lever roller, low force
A25
1.56" lever roller, low force
T10
.84" lever, high force
T13
1.34" simulated roller, high force
T14
1.29" simulated roller, high force
T15
1.40" lever, high force
T16
2.34" lever, high force
T17
2.00" lever, high force
T18
2.75" lever, high force
T20
1.06" lever, low force
T23
1.56" simulated roller, low force
T24
1.50" simulated roller, low force
T25
1.62" lever, low force
T26
2.56" lever, low force
T27
2.22" lever, low force
T28
2.97" lever, low force
Terminations
40
.187" quick connect
10
Solder
4A
.250" quick connect
60
Screw
Circuitry
C
SPDT
W
SPST N.C.
Y
SPST N.O.
* All models
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
J–11
www.ck-components.com
MicroPython adds new description of pyb.Flash
MicroPython adds description of pyb.Flash classdocs/library: Add docs for pyb.Flash class....
dcexpert MicroPython Open Source section
Linux image burning demonstration based on TMS320C6678
1. Serial port debugging software configuration Before configuration, please use a Micro USB cable to connect the debug serial port and the computer terminal.Install and debug terminal softwareIt is r...
Tronlong小分队 Linux and Android
How to reload or reload ntdll.dll and other system core libraries!
Nowadays, the system core library is usually modified by various software once it is loaded into memory, such as antivirus software, virus software, and even game anti-cheating software. I want to loa...
struct Embedded System
dsp serial port f28335
Help, I have been studying dsp for a long time, but still can't get the point~~ I have begun to doubt my IQ~~~A very easy question, about the f28335 serial port program, I burned it on the development...
踏雪垂钓 DSP and ARM Processors
The third batch of LaunchPads received
The courier delivered it to my workplace after get off work yesterday, and I saw it early in the morning. Thanks to EEWorld & TI, give it a thumbs up, and wish EEWORLD will do better and better! ! ! :...
zk47 Microcontroller MCU
[Award Ceremony] The winners of the Meixin Quiz are announced! Congratulations to all the winners!
[font=微软雅黑][size=3]The Meixin quiz event has come to an end, and the winners have been announced. Congratulations to all the winners! Please contact the administrator [color=#ff0000]linjiang[/color] b...
linjiang Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2528  312  2773  1257  1109  51  7  56  26  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号