EEWORLDEEWORLDEEWORLD

Part Number

Search

4431.1028

Description
pushbutton switches UV protection switch push button 115v50hz
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size2MB,9 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

4431.1028 Overview

pushbutton switches UV protection switch push button 115v50hz

4431.1028 Parametric

Parameter NameAttribute value
ManufactureSchurte
Product CategoryPushbutton Switches
RoHSYes
Contact FormDPDT
Voltage Rating AC115 V
Termination StyleQuick Connect Terminal
ActuSquare
Factory Pack Quantity20
circuit breakers
Undervoltage protection switch, rocker or push button actuated, 2-pole
UP1-1WF …
UP1-3TF …
UP1-5TF …
UP1-8TF …
Description
2-pole switch with undervoltage release and restart protection
Remote trip version
Rocker and push button types
Snap-in or screw-on version
Protection covers for IP 54 or IP 65
References
– Last order Date:
31.03.2014
– Availability: On request
– This type is Phase-Out without alternate type.
Applications
– Electric power tools such as circular saw, band saw, band grinder,
miter-box saw, drilling machine, stone/masonry saw
– Chain grinder
– Floor grinder
– Floor cleaning equipments
– Concrete mixers
Approvals
IEC 60947-4-1
UL 508
CSA 22.2 No. 14-95
Technical Data
Rated voltage
AC 240 V / 50/60 Hz
AC 230 V / 50/60 Hz
AC 120 V / 60 Hz
AC 115 V / 50/60 Hz
16 A
(AC-1)
14.5 A (AC-3)
10 A
(1.5 HP)
AC 2000 A @ PC 1
CB 16 A, char. B
50 Hz:
Impulse:
II
Switch type (S)
Terminals side:
Mode of tripping
– Manual ON:
– Automatic release:
Type of tripping
Undervoltage release (UV)
35% … 85% Un (and higher)
35% … 70% Un (and lower)
Non-trip-free
1500 V
2500 V
Shock resistance
Endurance
50 000 cycles mechanical
50 000 cycles 16 A / AC-1
50 000 cycles 10 A / AC-3
35 000 cycles 14.5 A / AC-3
Rated current
Ambient temperature
Operation
Storage
Resistance to vibration
–10 °C … + 60 °C
–20 °C … + 80 °C
IEC 60068-2-6, Test Fc
10 … 60 Hz: 0.75 mm
60 … 500 Hz: 10 G
IEC 60068-2-27, Test Ea
30 G / 18 ms (half-sine)
Conditional short circuit
Capacity I
nc
Fuse
Dielectric strength
Overvoltage category
Method of operation
Degree of protection:
Accessible range:
Rocker types IP 40
Push button types IP 54
IP 00
2
circuit breakers

4431.1028 Related Products

4431.1028 4431.1040 4431.1038 4431.1008 4431.1017 4431.1018 4431.1039 4431.1045 4431.1029
Description pushbutton switches UV protection switch push button 115v50hz pushbutton switches UV protection switch push button 115v60hz pushbutton switches UV protection switch push button 115v50hz pushbutton switches UV protection switch push button 230v50hz pushbutton switches UV protection switch push button 230v60hz pushbutton switches UV protection switch push button 115v50hz pushbutton switches UV protection switch push button 230v60hz pushbutton switches UV protection switch push button 230v60hz pushbutton switches UV protection switch push button 240v60hz
Manufacture Schurte Schurte Schurte Schurte Schurte Schurte Schurte - -
Product Category Pushbutton Switches Pushbutton Switches Pushbutton Switches Pushbutton Switches Pushbutton Switches Pushbutton Switches Pushbutton Switches - -
RoHS Yes Yes Yes Yes Yes Yes Yes - -
Contact Form DPDT DPDT DPDT DPDT DPDT DPDT DPDT - -
Voltage Rating AC 115 V 115 V 115 V 230 V 230 V 115 V 230 V - -
Termination Style Quick Connect Terminal Quick Connect Terminal Quick Connect Terminal Quick Connect Terminal Quick Connect Terminal Quick Connect Terminal Quick Connect Terminal - -
Actu Square Square Square Square Square Square Square - -
Factory Pack Quantity 20 10 10 15 16 16 10 - -
Hello everyone, welcome to join Google Android's QQ group: 62710437
Hello everyone, welcome to join the Google Android QQ group: 62710437. Let's discuss, explore and make progress together!...
lxd1227 Embedded System
[Help] How to run three tasks on UCOS with 1k of RAM?
I use f437, 1k ram. I can run two tasks now, no problem. But when I run three tasks, it fails. I wonder if any heroes can give some guidance....
tanta Microcontroller MCU
Wince5.0 horizontal screen to vertical screen problem
The CPU used is Samsung 2450. Under Wince5.0, I changed the horizontal screen to vertical screen. According to the method under 2440, I set the registry key to HKEY_LOCAL_MACHINE\System\GDI\Rotation] ...
fengyongbo Embedded System
PCB
Can someone please tell me how to draw the terminal in PCB?...
305374869 PCB Design
msp430g2553 alarm clock source program
#include"config.h" #define SDA_DIR_OUT P1DIR|=BIT4 #define SDA_DIR_IN P1DIR&=~BIT4 #define SCL_DIR_OUT P1DIR|=BIT5 #define SDA_IN P1IN&BIT4 #define SDA1 P1OUT|=BIT4 #define SDA0 P1OUT&=~BIT4 #define S...
Jacktang Microcontroller MCU
How to remove all machine1 layers after altium imports PCB from PCB library file, in addition to not displaying machine1
How to remove all machine1 layers after altium imports PCB from PCB library file, in addition to not displaying machine1...
chuzhaonan PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 281  206  1484  987  205  6  5  30  20  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号