TECHNICAL DATA SHEET
ADAPTOR
MCX JACK – N 50
Ω
PLUG
29K153-S00Z3
All dimensions are in mm; tolerances acc. ISO 2768 m-H
Interface
According to
MCX side:
N side:
CECC 22 220, IEC 60169-36
IEC 60169-16, MIL-PRF-39012, CECC 22210
Documents
N/A
Material and plating
Connector parts
Center contact
Outer contact MCX side
Outer contact N side
Dielectric
Material
Beryllium copper
Brass
Brass
PTFE
Plating
Gold, min. 1.27 m, over nickel
Gold, min. 1.27 m, over nickel
Nickel, 2.5-5 m
RF_35/12.04/3.0
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.: +49 8684 18-0
Fax: +49 8684 18-499
email: info@rosenberger.de
Page
1/2
TECHNICAL DATA SHEET
ADAPTOR
MCX JACK – N 50
Ω
PLUG
Electrical data
Impedance
Frequency
Return loss
Insertion loss
Insulation resistance
Center contact resistance
Outer contact resistance
Test voltage
Working voltage
Contact Current
50
Ω
DC to 6 GHz
≥
20 dB, DC to 1 GHz
≥
17 dB, 1 to 3 GHz
≤
0.05 x
f(GHz)
dB, DC to 3 GHz
≥
1 GΩ
≤
5.0 mΩ, MCX side;
≤
1 mΩ, N side
≤
2.5 mΩ, MCX side;
≤
0.25 mΩ, N side
750 V rms
335 V rms
1.5A DC max.
29K153-S00Z3
Mechanical data
Mating cycles
Coupling nut retention
Center contact captivation: axial
Engagement force
Disengagement force
Coupling test torque
Recommended torque
MCX side
≥
500
N/A
≥
28 N
≤
25 N
8 N min. to 20 N max.
N/A
N/A
N side
min. 500
≥
450 N
≥
28 N
N/A
N/A
max. 1.7 Nm
0.7 Nm to 1.1 Nm
Environmental data
Temperature range
Thermal shock
Vibration
Corrosion
Moisture resistance
-55°C to +155°C
CECC 22 220, Chapter
CECC 22 220, Chapter
CECC 22 220, Chapter
CECC 22 220, Chapter
4.6.7
4.6.3
4.6.10
4.6.6
Tooling
N/A
Suitable cables
N/A
Packing
Standard
Weight
1 pce in bag
26.5 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
RF_35/12.04/3.0
Draft
Inge Mühlauer
Date
30/08/04
Approved
Chr. Entsfellner
Date
23/02/05
Rev.
a00
Engineering change number
04-0130
Name
Rong Fang
Date
11/02/05
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.: +49 8684 18-0
Fax: +49 8684 18-499
email: info@rosenberger.de