Operating Temperature Range -20°C to +70°C or -40°C to +85°C
Tape and Reel Packaging, EIA-418
Wireless Communications
Broadband Access
FPGA/Microcontrollers
Computer Peripherals
Microprocessors
Test and Measurement
Consumer Electronics
Portable Equipment
Part Dimensions:
11.1 × 4.83 × 3.2mm
•
587.84mg
Applications
Description
CTS ATSSMLP incorporates a high Q quartz resonator in a proven resistance-weld metal package. ATSSMLP offers
tight stability options that are ideal for supporting a wide range of commercial and industrial applications.
Ordering Information
Model
LP
Frequency Code
[MHz]
XXX
Mode of
Oscillation
F
Tolerance
@ +25°C
3
Temperature
Stability
3
Temperature
Range
I
Load
Capacitance
D
Packaging
T
Code
Frequency
Product Frequency Code
1
Code
1
X
2
Y
3
Tolerance
±10ppm
±15ppm
±20ppm
±25ppm
±30ppm
Code Temp. Range
-20°C to +70°C
C
-40°C to +85°C
I
Packing
Code
Tape & Reel
T
Code
F
T
Mode
Fundamental
3rd Overtone
Code
1
X
2
Y
3
5
Stability
±10ppm
±15ppm
±20ppm
±25ppm
±30ppm
±50ppm
2
Code Capacitance Code Capacitance
K
D
8pF
18pF
9pF
20pF
J
E
10pF
24pF
A
F
12pF
30pF
L
G
13pF
32pF
B
H
16pF
Series
C
S
Notes:
1] Refer to document 016-1454-0, Frequency Code Tables. 3-digits for frequencies <100MHz.
2] Check factory availability when combined with -40°C to +85°C temperature range.
Not all performance combinations and frequencies may be available.
Contact your local CTS Representative or CTS Customer Service for availability.
This product is specified for use only in standard commercial applications. Supplier disclaims all express and implied warranties and liability in connection with any use of this
product in any non-commercial applications or in any application that may expose the product to conditions that are outside of the tolerances provided in its specification.
Example : Using TOPWAY Smart LCD (HMT050CC-C) to display animation
The first step is to create a project
Step 2: Create a page and import the background image
Step 3: Associate the page with the backg...
I want to test the motion detection function of the video server. I have an ARM linux board with source code. But I don't know how to test it. I don't know much about it. I searched the Internet but c...
I wrote a program to send data to Panasonic PLC, such as sending data 50 to PLC DT100, and then displaying the data in PLC DT100. This function has been successfully implemented. Now the customer's ne...
3V and 5V interface issues in MSP430 system design. This is MSP430 application technical information, very practical, suitable for drawing PCB boards! ! ! [[i] This post was last edited by Xinhai Baby...