60W Single Output Class 2 Switching Power Supply
ELN-60
series
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
ELN-60-9
9V
5A
0 ~ 5A
45W
8.7 ~ 10.5V
LED OPERATION VOLTAGE
Note.8
3 ~ 9V
ELN-60-12
12V
6 ~ 12V
5A
0 ~ 5A
60W
120mVp-p
10.8 ~ 13.2V
¡½
Features :
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Optional dimming function : 1~10VDC (D type) or PWM (P type) controlled
Fully isolated plastic case with IP64 level
Class
power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications (Note.9)
100% full load burn-in test
Low cost, high reliability
2 years warranty
¢º
LPS
IP64
ELN-60-24
24V
12 ~ 24V
2.5A
0 ~ 2.5A
60W
150mVp-p
21.6 ~ 26.4V
( for 48V only)
( except for 48V )
ELN-60-15
15V
7.5 ~ 15V
4A
0 ~ 4A
60W
150mVp-p
13.5 ~ 16.5V
ELN-60-27
27V
13.5 ~ 27V
2.3A
0 ~ 2.3A
62.1W
200mVp-p
24.3 ~ 29.7V
ELN-60-48
48V
24 ~ 48V
1.3A
0 ~ 1.3A
62.5W
250mVp-p
43.2 ~ 52.8V
RIPPLE & NOISE (max.)
Note.2
120mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
Note.7
Can be adjusted by internal potentiometer SVR1
CURRENT ADJ. RANGE
Note.7
-25% ~ 3%. Can be adjusted by internal potentiometer SVR2
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
LEAKAGE CURRENT
OVER CURRENT
PROTECTION
OVER VOLTAGE
¡Ó
5.0%
¡Ó
1.0%
¡Ó
2.0%
Note.6
500ms, 30ms / 230VAC
1500ms, 30ms / 115VAC at full load
50ms/230VAC
Note.4
90 ~ 264VAC
16ms/115VAC at full load
127 ~ 370VDC
85%
0.7A/230VAC
86%
87%
87%
88%
47 ~ 63Hz
82%
1.2A/115VAC
COLD START 60A(t
width
=600 s measured at 50% I
peak
) at 230VAC
0.25mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
11 ~ 13.5V
13.8 ~ 16V
17.5 ~ 21V
28 ~ 32V
31 ~ 37V
54 ~ 60V
£g
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION DIMMING CONTROL
(OPTIONAL)
1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
-20 ~ +60
¢J
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
¢J
¡Ó
0.03%/
¢J
(0 ~ 50
¢J
)
I/P-O/P:3KVAC
-40 ~ +80 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
603K hrs min. MIL-HDBK-217F (25 )
181*61.5*35mm (L*W*H)
0.4Kg; 24pcs/11Kg/0.75CUFT
¢J
¢J
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
9. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name:ELN-60-SPEC 2012-12-26
¢J
60W Single Output Class 2 Switching Power Supply
Dimming Control (Optional)
Level of output current can be adjusted through the dimming control function.
When there is no signal sending to the control wires (open circuit between the two control wires), the power supply
unit will operate as 0V (D-type) or 0% duty (P-type) of input signal and hence the output current will be zero.
(1)1~10V (D type, & : ELN-60- 12 D)
ELN-60
series
95%
DIM+
Vdc
Output Current
+
DIM-
Vdc:
1~10V
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
0
45%
5%
1
2
3
4
5
6
7
8
9
10
DC Input
(2)PWM (P type, & : ELN-60- 12 P)
V
f: 100Hz ~ 3KHz
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
0%
11%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95%
Output Current
f
10V
60%
t1
t2
f
15%
Duty= t1 ,0 ~ 100%
t1+t2
Lo:0V
Hi:10V
Duty Cycle
File Name:ELN-60-SPEC 2012-12-26