EEWORLDEEWORLDEEWORLD

Part Number

Search

2210-S231-P1M1-Z241-8A

Description
Thermal Magnetic Circuit Breaker,
CategoryCircuit protection    Circuit protection   
File Size382KB,6 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance
Download Datasheet Parametric View All

2210-S231-P1M1-Z241-8A Online Shopping

Suppliers Part Number Price MOQ In stock  
2210-S231-P1M1-Z241-8A - - View Buy Now

2210-S231-P1M1-Z241-8A Overview

Thermal Magnetic Circuit Breaker,

2210-S231-P1M1-Z241-8A Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7266947202
Reach Compliance Codecompliant
Actuator typeTOGGLE HANDLE
body width37.5 mm
body height68 mm
Body length or diameter50 mm
circuit functionTRIP FREE
Circuit protection typeTHERMAL MAGNETIC CIRCUIT BREAKER
Environmental characteristicsCORROSION RESISTANT; IP00; IP30
Installation featuresPANEL MOUNT
Number of poles3
Maximum operating temperature60 °C
Minimum operating temperature-30 °C
Rated breaking capacity5000 A
Rated current8 A
Rated voltage (AC)480 V
Rated voltage (DC)65 V
GuidelineCSA; UL
surface mountNO
Terminal shapeQUICK CONNECT
Thermal-Magnetic Circuit Breaker 2210-S2...
Description
One, two and three pole thermal-magnetic circuit breakers with tripfree
mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC
934). Designed for panel or plug-in mounting. Available with auxiliary
contacts (1 x N/O, 1 x N/C) for status signalling. Two and three pole
models are internally linked to ensure that both/all poles trip in the
event of an overload on one pole, even if the actuator is held in the ON
position. A choice of characteristic curves further extends the range
of applications possibilities for these CBEs. Special auxiliary contact
versions for industrial atmosphere and low voltages (e. g. 5 V) available
on request.
Approved to CBE standard EN 60934 (IEC 60934).
Suitable for use in distribution rails – see section Power Distribution
Systems.
1
2210-S2..
Technical data
For further details please see chapter: Technical Information
Voltage rating
AC 250 V*; 3 AC 433 V (50-60Hz); DC 65 V
(*UL: AC 277/480 V; DC 65 V)
Current rating range
0.1...25 A for curves M1, T1
0.1...16 A for curves F1, F2
1...16 A for curves M3
Auxiliary circuit
1 A, AC 240 V/DC 65 V, resistive
(min. 10 V / 10 mA)
Typical life
10,000 operations at 1 x I
N
, inductive
Ambient temperature
-30...+60 °C (-22...+140 °F) T 60
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area
AC 3,000 V
main/aux. circuit
AC 1,500 V
aux. circuit 11-12/23-24 AC 1,000 V
pole/pole
AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.1...5 A
400 A
6...25 A
800 A
curves F1, F2, M1, T1: 0.1...16 A
2,500A (at DC 32 V)
curve M3:
1...2 A AC
200 A
DC 400 A
Interrupting capacity (UL 1077)
I
N
0.1...16 A
20...25 A
Typical applications
Process control equipment, robotics, machine tool control, communications
systems, instrumentation, rail vehicles. Special versions, e.g. for aggressive
environmental conditions and low voltages (e. g. 5 V) on request.
Standard current ratings and typical internal resistance values
Current
rating (A)
Internal resistance (Ω)
F1
fast acting
for DC only
F2
fast acting
delay
for AC+DC
M1
standard
for AC+DC
T1
delayed
low
resistance
only for AC
M3
standard
delay
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.5
2
2.5
3
4
5
6
8
10
12
16
20
25
162
39.3
17.5
9.2
6.8
4.2
2.8
1.6
0.78
0.42
0.26
0.18
0.12
0.092
0.054
0.025
0.022
≤ 0.02
≤ 0.02
-
-
162
39.3
17.5
9.2
6.8
4.2
2.8
1.6
0.78
0.42
0.26
0.18
0.12
0.092
0.054
0.025
0.02
≤ 0.02
≤ 0.02
-
-
92
26.1
11.6
6.6
4.1
3
1.65
1.10
0.47
0.28
0.183
0.124
0.077
0.063
0.045
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
81
24.2
10.4
6.0
3.9
2.7
1.53
0.98
0.42
0.24
0.17
0.12
0.073
0.055
0.039
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
-
-
-
-
-
-
-
0.5
0.22
0.136
0.083
0.057
0.041
0.032
0.021
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
-
-
AC 277 V
1-pole
AC 277/480 V
2-/3-pole
5,000 A
5,000 A
2,000 A
2,000 A
2,000 A
2,000 A
DC 65 V
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Preferred types
Preferred types
1-pole:
2210-S211-P1F1-H111-
2210-S211-P1M1-H111-
2210-S211-P1M1-Z111-
2-pole:
2210-S221-P1M1-H111-
2210-S221-P1M1-H211-
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Standard current ratings (A)
1
x
x
x
Shock
10
16
2
x
x
x
4
x
x
x
6
x
x
x
8
x
x
x
x
x
x
x
Corrosion
Humidity
Mass
operating area IP30
terminal area IP00
curves F1, F2:
3 g (57-500 Hz), ± 0.23 mm (10-57 Hz)
curves M1, M3, T1:
5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
curves F1, F2:
25 g (11 ms), directions 1, 2, 3, 4, 5
10 g (11 ms), direction 6
curves M1, M3, T1:
25 g (11 ms), directions 1, 2, 3, 4, 5
20 g (11 ms), direction 6
to IEC 60068-2-27, test Ea
96 hours in 5 % salt mist
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 50 g per pole
1812
www.e-t-a.de
1

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 505  2570  2422  311  2217  11  52  49  7  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号